Cargando…
A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1
A rapid and simple immuno-chromatographic assay was developed to detect aflatoxin B1 (AFB1). The assay was based on a modified competitive binding format using colloidal gold and polyclonal antibody (Pab) conjugates. The anti-AFB1 Pab was immobilized to a defined detection zone on a porous nitrocell...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5448957/ https://www.ncbi.nlm.nih.gov/pubmed/28817000 http://dx.doi.org/10.3390/ma5040634 |
_version_ | 1783239668726235136 |
---|---|
author | Moon, Jihea Kim, Giyoung Lee, Sangdae |
author_facet | Moon, Jihea Kim, Giyoung Lee, Sangdae |
author_sort | Moon, Jihea |
collection | PubMed |
description | A rapid and simple immuno-chromatographic assay was developed to detect aflatoxin B1 (AFB1). The assay was based on a modified competitive binding format using colloidal gold and polyclonal antibody (Pab) conjugates. The anti-AFB1 Pab was immobilized to a defined detection zone on a porous nitrocellulose membrane and colloidal gold particles were conjugated to AFB1-BSA which served as a detection reagent. The AFB1-containing sample was added to the membrane and allowed to move with AFB1-BSA-coated particles dried on the conjugation pad. The mixture was then passed along the porous membrane by capillary action past the Pab in the detection zone, which captured AFB1 or AFB1-BSA. AFB1 in the sample inhibits binding of AFB1-BSA conjugated gold particles to the Pab and prevents formation of a red color dot. In the absence of AFB1, AFB1-BSA conjugated gold particles bound to the Pab, give a red color within this detection zone. With this method, 10 μg/mL of AFB1 was detected in less than 10 min. The developed AFB1 assay also showed no cross reaction to Ochratoxin A (OTA). |
format | Online Article Text |
id | pubmed-5448957 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-54489572017-07-28 A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 Moon, Jihea Kim, Giyoung Lee, Sangdae Materials (Basel) Article A rapid and simple immuno-chromatographic assay was developed to detect aflatoxin B1 (AFB1). The assay was based on a modified competitive binding format using colloidal gold and polyclonal antibody (Pab) conjugates. The anti-AFB1 Pab was immobilized to a defined detection zone on a porous nitrocellulose membrane and colloidal gold particles were conjugated to AFB1-BSA which served as a detection reagent. The AFB1-containing sample was added to the membrane and allowed to move with AFB1-BSA-coated particles dried on the conjugation pad. The mixture was then passed along the porous membrane by capillary action past the Pab in the detection zone, which captured AFB1 or AFB1-BSA. AFB1 in the sample inhibits binding of AFB1-BSA conjugated gold particles to the Pab and prevents formation of a red color dot. In the absence of AFB1, AFB1-BSA conjugated gold particles bound to the Pab, give a red color within this detection zone. With this method, 10 μg/mL of AFB1 was detected in less than 10 min. The developed AFB1 assay also showed no cross reaction to Ochratoxin A (OTA). MDPI 2012-04-13 /pmc/articles/PMC5448957/ /pubmed/28817000 http://dx.doi.org/10.3390/ma5040634 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Moon, Jihea Kim, Giyoung Lee, Sangdae A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 |
title | A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 |
title_full | A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 |
title_fullStr | A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 |
title_full_unstemmed | A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 |
title_short | A Gold Nanoparticle and Aflatoxin B1-BSA Conjugates Based Lateral Flow Assay Method for the Analysis of Aflatoxin B1 |
title_sort | gold nanoparticle and aflatoxin b1-bsa conjugates based lateral flow assay method for the analysis of aflatoxin b1 |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5448957/ https://www.ncbi.nlm.nih.gov/pubmed/28817000 http://dx.doi.org/10.3390/ma5040634 |
work_keys_str_mv | AT moonjihea agoldnanoparticleandaflatoxinb1bsaconjugatesbasedlateralflowassaymethodfortheanalysisofaflatoxinb1 AT kimgiyoung agoldnanoparticleandaflatoxinb1bsaconjugatesbasedlateralflowassaymethodfortheanalysisofaflatoxinb1 AT leesangdae agoldnanoparticleandaflatoxinb1bsaconjugatesbasedlateralflowassaymethodfortheanalysisofaflatoxinb1 AT moonjihea goldnanoparticleandaflatoxinb1bsaconjugatesbasedlateralflowassaymethodfortheanalysisofaflatoxinb1 AT kimgiyoung goldnanoparticleandaflatoxinb1bsaconjugatesbasedlateralflowassaymethodfortheanalysisofaflatoxinb1 AT leesangdae goldnanoparticleandaflatoxinb1bsaconjugatesbasedlateralflowassaymethodfortheanalysisofaflatoxinb1 |