Cargando…

Time and frequency domain methods for quantifying common modulation of motor unit firing patterns

BACKGROUND: In investigations of the human motor system, two approaches are generally employed toward the identification of common modulating drives from motor unit recordings. One is a frequency domain method and uses the coherence function to determine the degree of linear correlation between each...

Descripción completa

Detalles Bibliográficos
Autores principales: Myers, Lance J, Erim, Zeynep, Lowery, Madeleine M
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC544949/
https://www.ncbi.nlm.nih.gov/pubmed/15679910
http://dx.doi.org/10.1186/1743-0003-1-2
_version_ 1782122182057394176
author Myers, Lance J
Erim, Zeynep
Lowery, Madeleine M
author_facet Myers, Lance J
Erim, Zeynep
Lowery, Madeleine M
author_sort Myers, Lance J
collection PubMed
description BACKGROUND: In investigations of the human motor system, two approaches are generally employed toward the identification of common modulating drives from motor unit recordings. One is a frequency domain method and uses the coherence function to determine the degree of linear correlation between each frequency component of the signals. The other is a time domain method that has been developed to determine the strength of low frequency common modulations between motor unit spike trains, often referred to in the literature as 'common drive'. METHODS: The relationships between these methods are systematically explored using both mathematical and experimental procedures. A mathematical derivation is presented that shows the theoretical relationship between both time and frequency domain techniques. Multiple recordings from concurrent activities of pairs of motor units are studied and linear regressions are performed between time and frequency domain estimates (for different time domain window sizes) to assess their equivalence. RESULTS: Analytically, it may be demonstrated that under the theoretical condition of a narrowband point frequency, the two relations are equivalent. However practical situations deviate from this ideal condition. The correlation between the two techniques varies with time domain moving average window length and for window lengths of 200 ms, 400 ms and 800 ms, the r(2 )regression statistics (p < 0.05) are 0.56, 0.81 and 0.80 respectively. CONCLUSIONS: Although theoretically equivalent and experimentally well correlated there are a number of minor discrepancies between the two techniques that are explored. The time domain technique is preferred for short data segments and is better able to quantify the strength of a broad band drive into a single index. The frequency domain measures are more encompassing, providing a complete description of all oscillatory inputs and are better suited to quantifying narrow ranges of descending input into a single index. In general the physiological question at hand should dictate which technique is best suited.
format Text
id pubmed-544949
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-5449492005-10-07 Time and frequency domain methods for quantifying common modulation of motor unit firing patterns Myers, Lance J Erim, Zeynep Lowery, Madeleine M J Neuroengineering Rehabil Research BACKGROUND: In investigations of the human motor system, two approaches are generally employed toward the identification of common modulating drives from motor unit recordings. One is a frequency domain method and uses the coherence function to determine the degree of linear correlation between each frequency component of the signals. The other is a time domain method that has been developed to determine the strength of low frequency common modulations between motor unit spike trains, often referred to in the literature as 'common drive'. METHODS: The relationships between these methods are systematically explored using both mathematical and experimental procedures. A mathematical derivation is presented that shows the theoretical relationship between both time and frequency domain techniques. Multiple recordings from concurrent activities of pairs of motor units are studied and linear regressions are performed between time and frequency domain estimates (for different time domain window sizes) to assess their equivalence. RESULTS: Analytically, it may be demonstrated that under the theoretical condition of a narrowband point frequency, the two relations are equivalent. However practical situations deviate from this ideal condition. The correlation between the two techniques varies with time domain moving average window length and for window lengths of 200 ms, 400 ms and 800 ms, the r(2 )regression statistics (p < 0.05) are 0.56, 0.81 and 0.80 respectively. CONCLUSIONS: Although theoretically equivalent and experimentally well correlated there are a number of minor discrepancies between the two techniques that are explored. The time domain technique is preferred for short data segments and is better able to quantify the strength of a broad band drive into a single index. The frequency domain measures are more encompassing, providing a complete description of all oscillatory inputs and are better suited to quantifying narrow ranges of descending input into a single index. In general the physiological question at hand should dictate which technique is best suited. BioMed Central 2004-10-14 /pmc/articles/PMC544949/ /pubmed/15679910 http://dx.doi.org/10.1186/1743-0003-1-2 Text en Copyright © 2004 Myers et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License ( (http://creativecommons.org/licenses/by/2.0) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Myers, Lance J
Erim, Zeynep
Lowery, Madeleine M
Time and frequency domain methods for quantifying common modulation of motor unit firing patterns
title Time and frequency domain methods for quantifying common modulation of motor unit firing patterns
title_full Time and frequency domain methods for quantifying common modulation of motor unit firing patterns
title_fullStr Time and frequency domain methods for quantifying common modulation of motor unit firing patterns
title_full_unstemmed Time and frequency domain methods for quantifying common modulation of motor unit firing patterns
title_short Time and frequency domain methods for quantifying common modulation of motor unit firing patterns
title_sort time and frequency domain methods for quantifying common modulation of motor unit firing patterns
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC544949/
https://www.ncbi.nlm.nih.gov/pubmed/15679910
http://dx.doi.org/10.1186/1743-0003-1-2
work_keys_str_mv AT myerslancej timeandfrequencydomainmethodsforquantifyingcommonmodulationofmotorunitfiringpatterns
AT erimzeynep timeandfrequencydomainmethodsforquantifyingcommonmodulationofmotorunitfiringpatterns
AT lowerymadeleinem timeandfrequencydomainmethodsforquantifyingcommonmodulationofmotorunitfiringpatterns