Cargando…

The value of Sonoclot detection technology to guide the clinical medication of the perioperative anticoagulation and antiplatelet therapy in patients with acute myocardial infarction undergoing emergent PCI

The value of Sonoclot detection technology to guide the clinical medication of the perioperative anticoagulation and antiplatelet therapy in patients with acute myocardial infarction (AMI) undergoing emergent percutaneous coronary intervention (PCI) was estimated. One hundred and twenty-eight patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Wu-Xiao, Lai, Chun-Lin, Chen, Fu-Heng, Wang, Ji-Rong, Ji, You-Rui, Wang, Dong-Xia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5450559/
https://www.ncbi.nlm.nih.gov/pubmed/28587360
http://dx.doi.org/10.3892/etm.2017.4336
Descripción
Sumario:The value of Sonoclot detection technology to guide the clinical medication of the perioperative anticoagulation and antiplatelet therapy in patients with acute myocardial infarction (AMI) undergoing emergent percutaneous coronary intervention (PCI) was estimated. One hundred and twenty-eight patients were randomly divided into control group and observation group with 64 cases in each group. Control group adopted routine blood coagulation indexes, including prothrombin time, activated partial thromboplastin time, fibrinogen and plasma thrombin time, platelet count and platelet aggregation turbidity analysis; observation group adopted Sonoclot detection technology, including activated clotting time, coagulation rate and platelet function. Anticoagulant therapy selected was of low molecular weight heparin calcium perioperatively, intraoperative unfractionated heparin, and clopidogrel (75 mg) combined with aspirin enteric-coated tablets (100 mg) as antiplatelet drugs. The therapy was administered in accordance with blood coagulation results. The blood coagulation time, postoperative creatine kinase isoenzyme MB, cardiac troponin I and B-type natriuretic peptide levels in the observation group are significantly lower than those in the control group (P<0.05) though the operating time and specifications of the stenting did not show any significant difference (P>0.05). The incidence of recurrent myocardial infarction, microembolism, acute and subacute thrombosis and bleeding events in the observation group are significantly lower than those in the control group (P<0.05). In the control group, there is no difference in the coagulation indexes of the patients with thrombosis events or bleeding events or no event (P>0.05). Whereas, in the observation group, there is significant difference in coagulation indexes of the patients with thrombosis events or bleeding events or no event (P<0.05). In conclusion, Sonoclot detection technology instructs emergent PCI treatment in AMI patients to shorten the detection time of blood coagulation, reduce the degree of myocardial injury, reduce the incidence of perioperative thrombosis and bleeding events. Furthermore, it has great value in guiding the clinical medication of anticoagulation and antiplatelet therapy.