Cargando…

Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia

We conducted the present study to investigate the effects of the different loading doses of dexmedetomidine hydrochloride in the prevention of adverse reactions after combined spinal-epidural anesthesia. A total of 200 patients that were admitted to the Department of Obstetrics at the Second Affilia...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Wanwei, Wang, Qinghui, Xu, Min, Li, Yu, Yang, Rui, Song, Xiaoyang, Duan, Haixia, Zhang, Pengbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5450646/
https://www.ncbi.nlm.nih.gov/pubmed/28587365
http://dx.doi.org/10.3892/etm.2017.4335
_version_ 1783240022483271680
author Jiang, Wanwei
Wang, Qinghui
Xu, Min
Li, Yu
Yang, Rui
Song, Xiaoyang
Duan, Haixia
Zhang, Pengbo
author_facet Jiang, Wanwei
Wang, Qinghui
Xu, Min
Li, Yu
Yang, Rui
Song, Xiaoyang
Duan, Haixia
Zhang, Pengbo
author_sort Jiang, Wanwei
collection PubMed
description We conducted the present study to investigate the effects of the different loading doses of dexmedetomidine hydrochloride in the prevention of adverse reactions after combined spinal-epidural anesthesia. A total of 200 patients that were admitted to the Department of Obstetrics at the Second Affiliated Hospital of Xi'an Jiaotong University hospital and treated with cesarean section through the use of combined spinal-epidural anesthesia from December, 2014 to June, 2016, were randomly divided into 4 groups. The therapeutic regimens of patients were shown as follows: group A was administered an intravenous pump of 10 ml/l physiological saline in surgery until the end of the delivery. group B was administered 0.2 µg/kg dexmedetomidine. group C was administered 0.4 µg/kg dexmedetomidine. group D was administered 0.6 µg/kg dexmedetomidine. The anesthesia plane was adjusted to the level below the T10 plane. After the onset of anesthesia, participants of each group were treated with an intravenous pump of dexmedetomidine at loading dose. After intravenous pumping for 10 min in each group during the surgery, patients were administered with an intraoperative maintenance dose of 0.2 µg/kg/h until the end of the delivery. The heart rate (HR), mean arterial pressure (MAP), Narcotrend index (NI), Ramsay sedation score and the incidence of adverse reactions at each time-point of the start of drug administration (T0), 10 min (T2), 30 min (T3), 60 min (T4), 90 min (T5) and the end of surgery (T6) were recorded. Within 24 h post-delivery, the degree of amnesia from using dexmedetomidine until the end of the delivery were followed up. Compared to group A and T0, the HRs of participants at T3-6 in groups B and C were decreased. The MAP at T1 in group D was increased. In groups B and C, the NIs were significantly decreased at T2-6, the Ramsay scores were increased at T3-6, and the differences were statistically significant (P<0.05). The follow-up within 24 h after delivery showed that the degree of anterograde amnesia from groups B to D was significantly higher than group A, with statistically significant difference (P<0.05). A combined spinal-epidural anesthesia with 0.6 µg/kg loading dose of dexmedetomidine, by intravenous pumping within 10 min before cesarean section, can achieve a satisfied sedative effect at 30 min after administration. It maintains the characteristics of intraoperative hemodynamic stability and less adverse reactions. Therefore, it is of great significance to improve the quality of cesarean section delivery.
format Online
Article
Text
id pubmed-5450646
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-54506462017-06-05 Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia Jiang, Wanwei Wang, Qinghui Xu, Min Li, Yu Yang, Rui Song, Xiaoyang Duan, Haixia Zhang, Pengbo Exp Ther Med Articles We conducted the present study to investigate the effects of the different loading doses of dexmedetomidine hydrochloride in the prevention of adverse reactions after combined spinal-epidural anesthesia. A total of 200 patients that were admitted to the Department of Obstetrics at the Second Affiliated Hospital of Xi'an Jiaotong University hospital and treated with cesarean section through the use of combined spinal-epidural anesthesia from December, 2014 to June, 2016, were randomly divided into 4 groups. The therapeutic regimens of patients were shown as follows: group A was administered an intravenous pump of 10 ml/l physiological saline in surgery until the end of the delivery. group B was administered 0.2 µg/kg dexmedetomidine. group C was administered 0.4 µg/kg dexmedetomidine. group D was administered 0.6 µg/kg dexmedetomidine. The anesthesia plane was adjusted to the level below the T10 plane. After the onset of anesthesia, participants of each group were treated with an intravenous pump of dexmedetomidine at loading dose. After intravenous pumping for 10 min in each group during the surgery, patients were administered with an intraoperative maintenance dose of 0.2 µg/kg/h until the end of the delivery. The heart rate (HR), mean arterial pressure (MAP), Narcotrend index (NI), Ramsay sedation score and the incidence of adverse reactions at each time-point of the start of drug administration (T0), 10 min (T2), 30 min (T3), 60 min (T4), 90 min (T5) and the end of surgery (T6) were recorded. Within 24 h post-delivery, the degree of amnesia from using dexmedetomidine until the end of the delivery were followed up. Compared to group A and T0, the HRs of participants at T3-6 in groups B and C were decreased. The MAP at T1 in group D was increased. In groups B and C, the NIs were significantly decreased at T2-6, the Ramsay scores were increased at T3-6, and the differences were statistically significant (P<0.05). The follow-up within 24 h after delivery showed that the degree of anterograde amnesia from groups B to D was significantly higher than group A, with statistically significant difference (P<0.05). A combined spinal-epidural anesthesia with 0.6 µg/kg loading dose of dexmedetomidine, by intravenous pumping within 10 min before cesarean section, can achieve a satisfied sedative effect at 30 min after administration. It maintains the characteristics of intraoperative hemodynamic stability and less adverse reactions. Therefore, it is of great significance to improve the quality of cesarean section delivery. D.A. Spandidos 2017-06 2017-04-13 /pmc/articles/PMC5450646/ /pubmed/28587365 http://dx.doi.org/10.3892/etm.2017.4335 Text en Copyright: © Jiang et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Jiang, Wanwei
Wang, Qinghui
Xu, Min
Li, Yu
Yang, Rui
Song, Xiaoyang
Duan, Haixia
Zhang, Pengbo
Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
title Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
title_full Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
title_fullStr Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
title_full_unstemmed Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
title_short Assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
title_sort assessment of different loading doses of dexmedetomidine hydrochloride in preventing adverse reaction after combined spinal-epidural anesthesia
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5450646/
https://www.ncbi.nlm.nih.gov/pubmed/28587365
http://dx.doi.org/10.3892/etm.2017.4335
work_keys_str_mv AT jiangwanwei assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT wangqinghui assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT xumin assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT liyu assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT yangrui assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT songxiaoyang assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT duanhaixia assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia
AT zhangpengbo assessmentofdifferentloadingdosesofdexmedetomidinehydrochlorideinpreventingadversereactionaftercombinedspinalepiduralanesthesia