Cargando…

Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model

The aim of the present study was to establish and evaluate a novel and reversible two-kidney, one-clip renovascular hypertensive rat model with a titanium vascular clip. A total of 40 male Sprague-Dawley rats were evenly and randomly divided into a sham-operated group, and 3, 7, 12 and 28D groups (n...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Li-Qiang, Zhang, Jian, Wang, Rong, Li, Jian-Xin, Gu, Yong-Quan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5450695/
https://www.ncbi.nlm.nih.gov/pubmed/28587402
http://dx.doi.org/10.3892/etm.2017.4386
_version_ 1783240030017290240
author Li, Li-Qiang
Zhang, Jian
Wang, Rong
Li, Jian-Xin
Gu, Yong-Quan
author_facet Li, Li-Qiang
Zhang, Jian
Wang, Rong
Li, Jian-Xin
Gu, Yong-Quan
author_sort Li, Li-Qiang
collection PubMed
description The aim of the present study was to establish and evaluate a novel and reversible two-kidney, one-clip renovascular hypertensive rat model with a titanium vascular clip. A total of 40 male Sprague-Dawley rats were evenly and randomly divided into a sham-operated group, and 3, 7, 12 and 28D groups (namely removing the vascular clip in the renovascular hypertensive model after 3, 7, 12 and 28 days, respectively). The systolic blood pressure (SBP) and plasma renin activity (PRA) were measured, and color duplex imaging was conducted before placing the clips, as well as before and after removing them. After placing the vascular clips, SBP and PRA in the 3, 7, 12 and 28D groups were significantly increased (SBP: Sham-operated vs. 3D groups, P=0.020; 3 vs. 7D groups, P=0.008; 7 vs. 28D groups, P=0.019; 12 vs. 28D groups, P=0.039, and between other groups P<0.001. PRA: 3 vs. 7D groups, P=0.001; 7 vs. 12D groups, P=0.004; 12 vs. 28D groups, P=0.040, and between other groups, P<0.001). After removing the clips, SBP were significantly reduced in the 3 and 7D groups (P=0.023, 0.040, 0.066 and 0.314 in the 3, 7, 12 and 28D groups, respectively), but were still significantly higher than that before placing clips in the 7, 12 and 28D groups (P=0.067, P=0.005, P<0.001 and P<0.001 in the 3, 7, 12 and 28D groups, respectively). After removing the clips, PRA was significantly reduced in each group (P<0.001, P<0.001, P=0.012 and P=0.049 in 3, 7, 12 and 28D groups, respectively), but still higher than that before placing the clips (P<0.001, P=0.001, P=0.001 and P=0.003 in 3, 7, 12 and 28D groups, respectively). Vascular imaging also indicates this model has a reversible property. In conclusion, a reversible renovascular hypertension rat model is feasible, and provides a basis for research on clinical ischemic nephropathy and renal artery revascularization.
format Online
Article
Text
id pubmed-5450695
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-54506952017-06-05 Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model Li, Li-Qiang Zhang, Jian Wang, Rong Li, Jian-Xin Gu, Yong-Quan Exp Ther Med Articles The aim of the present study was to establish and evaluate a novel and reversible two-kidney, one-clip renovascular hypertensive rat model with a titanium vascular clip. A total of 40 male Sprague-Dawley rats were evenly and randomly divided into a sham-operated group, and 3, 7, 12 and 28D groups (namely removing the vascular clip in the renovascular hypertensive model after 3, 7, 12 and 28 days, respectively). The systolic blood pressure (SBP) and plasma renin activity (PRA) were measured, and color duplex imaging was conducted before placing the clips, as well as before and after removing them. After placing the vascular clips, SBP and PRA in the 3, 7, 12 and 28D groups were significantly increased (SBP: Sham-operated vs. 3D groups, P=0.020; 3 vs. 7D groups, P=0.008; 7 vs. 28D groups, P=0.019; 12 vs. 28D groups, P=0.039, and between other groups P<0.001. PRA: 3 vs. 7D groups, P=0.001; 7 vs. 12D groups, P=0.004; 12 vs. 28D groups, P=0.040, and between other groups, P<0.001). After removing the clips, SBP were significantly reduced in the 3 and 7D groups (P=0.023, 0.040, 0.066 and 0.314 in the 3, 7, 12 and 28D groups, respectively), but were still significantly higher than that before placing clips in the 7, 12 and 28D groups (P=0.067, P=0.005, P<0.001 and P<0.001 in the 3, 7, 12 and 28D groups, respectively). After removing the clips, PRA was significantly reduced in each group (P<0.001, P<0.001, P=0.012 and P=0.049 in 3, 7, 12 and 28D groups, respectively), but still higher than that before placing the clips (P<0.001, P=0.001, P=0.001 and P=0.003 in 3, 7, 12 and 28D groups, respectively). Vascular imaging also indicates this model has a reversible property. In conclusion, a reversible renovascular hypertension rat model is feasible, and provides a basis for research on clinical ischemic nephropathy and renal artery revascularization. D.A. Spandidos 2017-06 2017-04-26 /pmc/articles/PMC5450695/ /pubmed/28587402 http://dx.doi.org/10.3892/etm.2017.4386 Text en Copyright: © Li et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Li, Li-Qiang
Zhang, Jian
Wang, Rong
Li, Jian-Xin
Gu, Yong-Quan
Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
title Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
title_full Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
title_fullStr Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
title_full_unstemmed Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
title_short Establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
title_sort establishment and evaluation of a reversible two-kidney, one-clip renovascular hypertensive rat model
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5450695/
https://www.ncbi.nlm.nih.gov/pubmed/28587402
http://dx.doi.org/10.3892/etm.2017.4386
work_keys_str_mv AT liliqiang establishmentandevaluationofareversibletwokidneyonecliprenovascularhypertensiveratmodel
AT zhangjian establishmentandevaluationofareversibletwokidneyonecliprenovascularhypertensiveratmodel
AT wangrong establishmentandevaluationofareversibletwokidneyonecliprenovascularhypertensiveratmodel
AT lijianxin establishmentandevaluationofareversibletwokidneyonecliprenovascularhypertensiveratmodel
AT guyongquan establishmentandevaluationofareversibletwokidneyonecliprenovascularhypertensiveratmodel