Cargando…

Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State

Aim: Most epidemiological and clinical studies calculated low-density lipoprotein-cholesterol (LDL-C) by Friedewald's formula which cannot be used in the postprandial samples. Although the homogeneous assays with poor analytical performance were withdrawn from the market, it remained unclear wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Miida, Takashi, Nishimura, Kunihiro, Hirayama, Satoshi, Miyamoto, Yoshihiro, Nakamura, Masakazu, Masuda, Daisaku, Yamashita, Shizuya, Ushiyama, Masaji, Komori, Toshiaki, Fujita, Naohisa, Yokoyama, Shinji, Teramoto, Tamio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japan Atherosclerosis Society 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5453684/
https://www.ncbi.nlm.nih.gov/pubmed/28321014
http://dx.doi.org/10.5551/jat.40006
_version_ 1783240710597640192
author Miida, Takashi
Nishimura, Kunihiro
Hirayama, Satoshi
Miyamoto, Yoshihiro
Nakamura, Masakazu
Masuda, Daisaku
Yamashita, Shizuya
Ushiyama, Masaji
Komori, Toshiaki
Fujita, Naohisa
Yokoyama, Shinji
Teramoto, Tamio
author_facet Miida, Takashi
Nishimura, Kunihiro
Hirayama, Satoshi
Miyamoto, Yoshihiro
Nakamura, Masakazu
Masuda, Daisaku
Yamashita, Shizuya
Ushiyama, Masaji
Komori, Toshiaki
Fujita, Naohisa
Yokoyama, Shinji
Teramoto, Tamio
author_sort Miida, Takashi
collection PubMed
description Aim: Most epidemiological and clinical studies calculated low-density lipoprotein-cholesterol (LDL-C) by Friedewald's formula which cannot be used in the postprandial samples. Although the homogeneous assays with poor analytical performance were withdrawn from the market, it remained unclear whether the currently available reagents for LDL-C and high-density lipoprotein-cholesterol (HDL-C) are as accurate for postprandial samples as for fasting samples. Methods: Fresh blood samples were collected from 59 non-diseased and 109 diseased subjects. Postprandial samples constituted 72.9% and 39.4% of these samples. LDL-C and HDL-C concentrations were measured using the homogeneous assays of four manufacturers (Denka Seiken, Wako, Kyowa Medex, and Sekisui Medical). Simultaneously, LDL-C and HDL-C concentrations were determined using the reference measurement procedures (RMPs) of the Centers for Disease Control and Prevention (CDC). Total errors were calculated using a routine method (TE(com)) and via error component analysis (TEeca). Results: All homogeneous assays for LDL-C and HDL-C met the National Cholesterol Education Program (NCEP) requirements in terms of coefficient of variation, and TE(com) in both non-diseased and diseased subjects. LDL-C and HDL-C values measured by the homogeneous assays were in good agreement with those measured by the RMPs in both fasting and postprandial samples. The TE(com) and TEeca values of the postprandial samples were similar to those of fasting samples, although the TEeca values were up to 4.4-fold greater than the TE(com) values. Conclusions: In both non-diseased and diseased subjects, the homogeneous assays for LDL-C and HDL-C of four manufacturers are as accurate for postprandial samples as for fasting samples.
format Online
Article
Text
id pubmed-5453684
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Japan Atherosclerosis Society
record_format MEDLINE/PubMed
spelling pubmed-54536842017-06-02 Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State Miida, Takashi Nishimura, Kunihiro Hirayama, Satoshi Miyamoto, Yoshihiro Nakamura, Masakazu Masuda, Daisaku Yamashita, Shizuya Ushiyama, Masaji Komori, Toshiaki Fujita, Naohisa Yokoyama, Shinji Teramoto, Tamio J Atheroscler Thromb Original Article Aim: Most epidemiological and clinical studies calculated low-density lipoprotein-cholesterol (LDL-C) by Friedewald's formula which cannot be used in the postprandial samples. Although the homogeneous assays with poor analytical performance were withdrawn from the market, it remained unclear whether the currently available reagents for LDL-C and high-density lipoprotein-cholesterol (HDL-C) are as accurate for postprandial samples as for fasting samples. Methods: Fresh blood samples were collected from 59 non-diseased and 109 diseased subjects. Postprandial samples constituted 72.9% and 39.4% of these samples. LDL-C and HDL-C concentrations were measured using the homogeneous assays of four manufacturers (Denka Seiken, Wako, Kyowa Medex, and Sekisui Medical). Simultaneously, LDL-C and HDL-C concentrations were determined using the reference measurement procedures (RMPs) of the Centers for Disease Control and Prevention (CDC). Total errors were calculated using a routine method (TE(com)) and via error component analysis (TEeca). Results: All homogeneous assays for LDL-C and HDL-C met the National Cholesterol Education Program (NCEP) requirements in terms of coefficient of variation, and TE(com) in both non-diseased and diseased subjects. LDL-C and HDL-C values measured by the homogeneous assays were in good agreement with those measured by the RMPs in both fasting and postprandial samples. The TE(com) and TEeca values of the postprandial samples were similar to those of fasting samples, although the TEeca values were up to 4.4-fold greater than the TE(com) values. Conclusions: In both non-diseased and diseased subjects, the homogeneous assays for LDL-C and HDL-C of four manufacturers are as accurate for postprandial samples as for fasting samples. Japan Atherosclerosis Society 2017-06-01 /pmc/articles/PMC5453684/ /pubmed/28321014 http://dx.doi.org/10.5551/jat.40006 Text en 2017 Japan Atherosclerosis Society This article is distributed under the terms of the latest version of CC BY-NC-SA defined by the Creative Commons Attribution License.http://creativecommons.org/licenses/by-nc-sa/3.0/
spellingShingle Original Article
Miida, Takashi
Nishimura, Kunihiro
Hirayama, Satoshi
Miyamoto, Yoshihiro
Nakamura, Masakazu
Masuda, Daisaku
Yamashita, Shizuya
Ushiyama, Masaji
Komori, Toshiaki
Fujita, Naohisa
Yokoyama, Shinji
Teramoto, Tamio
Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State
title Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State
title_full Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State
title_fullStr Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State
title_full_unstemmed Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State
title_short Homogeneous Assays for LDL-C and HDL-C are Reliable in Both the Postprandial and Fasting State
title_sort homogeneous assays for ldl-c and hdl-c are reliable in both the postprandial and fasting state
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5453684/
https://www.ncbi.nlm.nih.gov/pubmed/28321014
http://dx.doi.org/10.5551/jat.40006
work_keys_str_mv AT miidatakashi homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT nishimurakunihiro homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT hirayamasatoshi homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT miyamotoyoshihiro homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT nakamuramasakazu homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT masudadaisaku homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT yamashitashizuya homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT ushiyamamasaji homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT komoritoshiaki homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT fujitanaohisa homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT yokoyamashinji homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate
AT teramototamio homogeneousassaysforldlcandhdlcarereliableinboththepostprandialandfastingstate