Cargando…

Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients

INTRODUCTION: In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. METHODS: Pat...

Descripción completa

Detalles Bibliográficos
Autores principales: Lin, Cheng‐guang, Xu, Sen‐kui, Yao, Wen‐yan, Wu, Yu‐qi, Fang, Jian‐lan, Wu, Vincent W. C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5454330/
https://www.ncbi.nlm.nih.gov/pubmed/27741377
http://dx.doi.org/10.1002/jmrs.189
_version_ 1783240814941437952
author Lin, Cheng‐guang
Xu, Sen‐kui
Yao, Wen‐yan
Wu, Yu‐qi
Fang, Jian‐lan
Wu, Vincent W. C.
author_facet Lin, Cheng‐guang
Xu, Sen‐kui
Yao, Wen‐yan
Wu, Yu‐qi
Fang, Jian‐lan
Wu, Vincent W. C.
author_sort Lin, Cheng‐guang
collection PubMed
description INTRODUCTION: In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. METHODS: Patients were randomly assigned to one of the three immobilisation systems: (1) supine on head rest and base plate (HB); (2) supine with alpha cradle supporting the head and shoulder (AC); (3) supine with vacuum bag supporting the head and shoulder (VB). CBCT was conducted weekly for each patient on the linear accelerator. Image registration was conducted at the nasopharynx (NP) and cervical regions. The translational displacements (latero‐medial, antero‐posterior and cranio‐caudal), rotational displacements (pitch, yaw and roll) and 3D vectors obtained at the NP and cervical regions were recorded and compared among the three systems. RESULTS: The mean translational and rotational deviations were within 3 mm and 2°, respectively, and the range of 3D vector was 1.53–3.47 mm. At the NP region, the AC system demonstrated the smallest translational and rotational deviations and 3D vector. The differences were significant except for the latero‐medial, yaw and roll directions. Similarly, at the cervical region, the AC system showed smaller translational and rotational deviations and 3D vector, with only the cranio‐caudal and yaw deviations that did not reach statistical significance. CONCLUSIONS: Set up deviation was greater in the neck than the NP region. The set up accuracy of the AC system was better than the other two systems, and it is recommended for IMRT of NPC patients in our institution.
format Online
Article
Text
id pubmed-5454330
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-54543302017-06-06 Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients Lin, Cheng‐guang Xu, Sen‐kui Yao, Wen‐yan Wu, Yu‐qi Fang, Jian‐lan Wu, Vincent W. C. J Med Radiat Sci Original Articles INTRODUCTION: In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. METHODS: Patients were randomly assigned to one of the three immobilisation systems: (1) supine on head rest and base plate (HB); (2) supine with alpha cradle supporting the head and shoulder (AC); (3) supine with vacuum bag supporting the head and shoulder (VB). CBCT was conducted weekly for each patient on the linear accelerator. Image registration was conducted at the nasopharynx (NP) and cervical regions. The translational displacements (latero‐medial, antero‐posterior and cranio‐caudal), rotational displacements (pitch, yaw and roll) and 3D vectors obtained at the NP and cervical regions were recorded and compared among the three systems. RESULTS: The mean translational and rotational deviations were within 3 mm and 2°, respectively, and the range of 3D vector was 1.53–3.47 mm. At the NP region, the AC system demonstrated the smallest translational and rotational deviations and 3D vector. The differences were significant except for the latero‐medial, yaw and roll directions. Similarly, at the cervical region, the AC system showed smaller translational and rotational deviations and 3D vector, with only the cranio‐caudal and yaw deviations that did not reach statistical significance. CONCLUSIONS: Set up deviation was greater in the neck than the NP region. The set up accuracy of the AC system was better than the other two systems, and it is recommended for IMRT of NPC patients in our institution. John Wiley and Sons Inc. 2016-09-01 2017-06 /pmc/articles/PMC5454330/ /pubmed/27741377 http://dx.doi.org/10.1002/jmrs.189 Text en © 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs (http://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Lin, Cheng‐guang
Xu, Sen‐kui
Yao, Wen‐yan
Wu, Yu‐qi
Fang, Jian‐lan
Wu, Vincent W. C.
Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
title Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
title_full Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
title_fullStr Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
title_full_unstemmed Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
title_short Comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
title_sort comparison of set up accuracy among three common immobilisation systems for intensity modulated radiotherapy of nasopharyngeal carcinoma patients
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5454330/
https://www.ncbi.nlm.nih.gov/pubmed/27741377
http://dx.doi.org/10.1002/jmrs.189
work_keys_str_mv AT linchengguang comparisonofsetupaccuracyamongthreecommonimmobilisationsystemsforintensitymodulatedradiotherapyofnasopharyngealcarcinomapatients
AT xusenkui comparisonofsetupaccuracyamongthreecommonimmobilisationsystemsforintensitymodulatedradiotherapyofnasopharyngealcarcinomapatients
AT yaowenyan comparisonofsetupaccuracyamongthreecommonimmobilisationsystemsforintensitymodulatedradiotherapyofnasopharyngealcarcinomapatients
AT wuyuqi comparisonofsetupaccuracyamongthreecommonimmobilisationsystemsforintensitymodulatedradiotherapyofnasopharyngealcarcinomapatients
AT fangjianlan comparisonofsetupaccuracyamongthreecommonimmobilisationsystemsforintensitymodulatedradiotherapyofnasopharyngealcarcinomapatients
AT wuvincentwc comparisonofsetupaccuracyamongthreecommonimmobilisationsystemsforintensitymodulatedradiotherapyofnasopharyngealcarcinomapatients