Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis

OBJECTIVES: It has been long known that removal of the meniscus can lead to degenerative changes, and preserving surgery rather than meniscal resection is likely to have better long-term outcomes. Success rates after meniscal repair ranges from 60- 95%, but with most studies having small number of p...

Descripción completa

Detalles Bibliográficos
Autores principales: Eriksson, Karl, Rönnblad, Erik, Barenius, Bjorn, Engstrom, Bjorn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5455903/
http://dx.doi.org/10.1177/2325967117S00197
_version_ 1783241125555863552
author Eriksson, Karl
Rönnblad, Erik
Barenius, Bjorn
Engstrom, Bjorn
author_facet Eriksson, Karl
Rönnblad, Erik
Barenius, Bjorn
Engstrom, Bjorn
author_sort Eriksson, Karl
collection PubMed
description OBJECTIVES: It has been long known that removal of the meniscus can lead to degenerative changes, and preserving surgery rather than meniscal resection is likely to have better long-term outcomes. Success rates after meniscal repair ranges from 60- 95%, but with most studies having small number of patients. The purpose of this study was to review all meniscal repairs, and potential predictors for failure, during a 12-year period. METHODS: A dual center retrospective analysis was performed on two consecutive cohorts of meniscal repairs, during the period 1999-2011 and 1999-2010 respectively. Data from surgical protocols and follow up charts were reviewed including type of tear, location, associated injury to the knee, and surgery. Study endpoint was failure of repair, which was defined as a need for reoperation and secondary partial or total meniscal resection, within 3 years. Kaplan-Meier was used to assess repair device survival. Results were expressed as hazard ratios (HR) with 95% confidence intervals (CI) and were adjusted for confounding factors using cox regression. RESULTS: 954 meniscal repairs were performed on 918 patients (n = 536 males [58%] and 382 females [42%]) with a mean age of 23 years (12-60). 64% underwent medial meniscal repair and 36% underwent lateral meniscal repair. 4% were repaired both medially and laterally. 75% of the repairs were performed using meniscal sutures (predominantly Fast-Fix), and 25% of the meniscal tears were repaired using bioabsorbable arrows (Biofix). The median time from injury to surgery was 23 days (0-360). The reoperation rate in the whole cohort was 29%. 35% of the medial meniscal repairs failed and 17% failures were noted on the lateral side.
Repair with bioabsorbable arrows on the medial meniscus resulted in reoperation in 44% of the cases, whereas the reoperation rate for meniscal sutures was 32% on the medial side. On the lateral side 18% failures were noticed when using arrows, and 17% when sutures were used.
62% of the patients had a simultaneous anterior cruciate ligament (ACL) injury. When medial meniscal repair was preformed with simultaneous ACL-reconstruction 26% of the meniscal repairs failed, when no simultaneous ACL- reconstruction was performed 37% of the meniscal repairs failed and with no associated ACL-injury 41% of the meniscal repairs failed.
Analyzing failure in a multivariate cox regression, adjusted according to age, gender, meniscus, ACL-pathology and days- to-surgery, revealed a higher failure rate for medial meniscal repairs (HR 3.006 [2.074-4.355; p = 0.000). Bioabsorbable arrows had significantly more failures than meniscal sutures (HR 1.656 [1.207-2.273]; p = 0.002). With reference to no ACL injury, meniscal repairs performed with a simultaneous ACL-reconstruction resulted in less failure than when no simultaneous ACL-reconstruction was performed (HR 0.605 [0.413-0.885]; p = 0.010). CONCLUSION: The failure rate was significantly higher on the medial side, especially when using Biofix-arrows. Patients who underwent a simultaneous ACL-reconstruction had a significantly better healing than conservatively treated ACL-ruptures, and patients with no ACL-injury. Age and days-to-surgery were not significant factors for failure.
format Online
Article
Text
id pubmed-5455903
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-54559032017-06-12 Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis Eriksson, Karl Rönnblad, Erik Barenius, Bjorn Engstrom, Bjorn Orthop J Sports Med Article OBJECTIVES: It has been long known that removal of the meniscus can lead to degenerative changes, and preserving surgery rather than meniscal resection is likely to have better long-term outcomes. Success rates after meniscal repair ranges from 60- 95%, but with most studies having small number of patients. The purpose of this study was to review all meniscal repairs, and potential predictors for failure, during a 12-year period. METHODS: A dual center retrospective analysis was performed on two consecutive cohorts of meniscal repairs, during the period 1999-2011 and 1999-2010 respectively. Data from surgical protocols and follow up charts were reviewed including type of tear, location, associated injury to the knee, and surgery. Study endpoint was failure of repair, which was defined as a need for reoperation and secondary partial or total meniscal resection, within 3 years. Kaplan-Meier was used to assess repair device survival. Results were expressed as hazard ratios (HR) with 95% confidence intervals (CI) and were adjusted for confounding factors using cox regression. RESULTS: 954 meniscal repairs were performed on 918 patients (n = 536 males [58%] and 382 females [42%]) with a mean age of 23 years (12-60). 64% underwent medial meniscal repair and 36% underwent lateral meniscal repair. 4% were repaired both medially and laterally. 75% of the repairs were performed using meniscal sutures (predominantly Fast-Fix), and 25% of the meniscal tears were repaired using bioabsorbable arrows (Biofix). The median time from injury to surgery was 23 days (0-360). The reoperation rate in the whole cohort was 29%. 35% of the medial meniscal repairs failed and 17% failures were noted on the lateral side.
Repair with bioabsorbable arrows on the medial meniscus resulted in reoperation in 44% of the cases, whereas the reoperation rate for meniscal sutures was 32% on the medial side. On the lateral side 18% failures were noticed when using arrows, and 17% when sutures were used.
62% of the patients had a simultaneous anterior cruciate ligament (ACL) injury. When medial meniscal repair was preformed with simultaneous ACL-reconstruction 26% of the meniscal repairs failed, when no simultaneous ACL- reconstruction was performed 37% of the meniscal repairs failed and with no associated ACL-injury 41% of the meniscal repairs failed.
Analyzing failure in a multivariate cox regression, adjusted according to age, gender, meniscus, ACL-pathology and days- to-surgery, revealed a higher failure rate for medial meniscal repairs (HR 3.006 [2.074-4.355; p = 0.000). Bioabsorbable arrows had significantly more failures than meniscal sutures (HR 1.656 [1.207-2.273]; p = 0.002). With reference to no ACL injury, meniscal repairs performed with a simultaneous ACL-reconstruction resulted in less failure than when no simultaneous ACL-reconstruction was performed (HR 0.605 [0.413-0.885]; p = 0.010). CONCLUSION: The failure rate was significantly higher on the medial side, especially when using Biofix-arrows. Patients who underwent a simultaneous ACL-reconstruction had a significantly better healing than conservatively treated ACL-ruptures, and patients with no ACL-injury. Age and days-to-surgery were not significant factors for failure. SAGE Publications 2017-05-31 /pmc/articles/PMC5455903/ http://dx.doi.org/10.1177/2325967117S00197 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc-nd/3.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Eriksson, Karl
Rönnblad, Erik
Barenius, Bjorn
Engstrom, Bjorn
Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis
title Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis
title_full Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis
title_fullStr Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis
title_full_unstemmed Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis
title_short Meniscal Sutures are Superior to Bioabsorbable Arrows: Results After 918 Consecutive Meniscal Repairs in a Dual Center Analysis
title_sort meniscal sutures are superior to bioabsorbable arrows: results after 918 consecutive meniscal repairs in a dual center analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5455903/
http://dx.doi.org/10.1177/2325967117S00197
work_keys_str_mv AT erikssonkarl meniscalsuturesaresuperiortobioabsorbablearrowsresultsafter918consecutivemeniscalrepairsinadualcenteranalysis
AT ronnbladerik meniscalsuturesaresuperiortobioabsorbablearrowsresultsafter918consecutivemeniscalrepairsinadualcenteranalysis
AT bareniusbjorn meniscalsuturesaresuperiortobioabsorbablearrowsresultsafter918consecutivemeniscalrepairsinadualcenteranalysis
AT engstrombjorn meniscalsuturesaresuperiortobioabsorbablearrowsresultsafter918consecutivemeniscalrepairsinadualcenteranalysis