Cargando…

Efficacy of digital pupillometry for diagnosis of Horner syndrome

OBJECTIVES: To evaluate the efficacy of digital pupillometry in the diagnosis of anisocoria related to Horner syndrome in adult patients. DESIGN: Retrospective, observational, case control study. METHODS: Nineteen patients with unilateral Horner syndrome (Horner group) and age-matched controls of 30...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoo, Yung Ju, Yang, Hee Kyung, Hwang, Jeong-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456040/
https://www.ncbi.nlm.nih.gov/pubmed/28575101
http://dx.doi.org/10.1371/journal.pone.0178361
_version_ 1783241157633900544
author Yoo, Yung Ju
Yang, Hee Kyung
Hwang, Jeong-Min
author_facet Yoo, Yung Ju
Yang, Hee Kyung
Hwang, Jeong-Min
author_sort Yoo, Yung Ju
collection PubMed
description OBJECTIVES: To evaluate the efficacy of digital pupillometry in the diagnosis of anisocoria related to Horner syndrome in adult patients. DESIGN: Retrospective, observational, case control study. METHODS: Nineteen patients with unilateral Horner syndrome (Horner group) and age-matched controls of 30 healthy individuals with normal vision and neither optic nerve dysfunction nor pupillary abnormalities were included. Pupillary light reflex (PLR) of the Horner group and controls were measured by a dynamic pupillometer (PLR-200; NeurOptics Inc., Irvine, USA). Minimal and maximal (min/max) pupil diameters, latency, constriction ratio, constriction velocity, dilation velocity, and total time taken by the pupil to recover 75% of maximal pupil diameter (T75) were noted. PLR were measured at baseline in both groups and at 30–45 minutes later after 0.5% apraclonidine (Iopidine(®); Alcon Laboratories, Fort Worth, TX, USA) instillation in the Horner group. MAIN OUTCOME MEASURES: The PLR parameters in the affected eye and inter-eye difference before and after 0.5% apraclonidine instillation. RESULTS: In the Horner group, pupil diameters and T75 showed significant difference between the affected eye and unaffected contralateral eye at baseline (all P<0.00625). Compared to controls, inter-eye difference values of pupil diameters and T75 were significantly larger in the Horner group (all P<0.001). After 0.5% apraclonidine instillation, changes in pupil diameter and constriction ratio were significantly larger in the affected eye compared to the unaffected contralateral eye (all P<0.00625). The area under the receiver operating characteristic curves for diagnosing Horner syndrome were largest for baseline inter-eye difference in min/max pupil sizes (AUC = 0.975, 0.994), T75 (AUC = 0.838), and change in min/max pupil sizes after apraclonidine instillation (AUC = 0.923, 0.929, respectively). The diagnostic criteria for Horner syndrome relying on baseline pupillary measurements was defined as one of the two major findings; 1) smaller maximal pupil diameter in the affected eye with an inter-eye difference of > 0.5 mm, or 2) T75 > 2.61 seconds in the affected eye, which showed a sensitivity of 94.7% and specificity of 93.3%. The diagnostic accuracy of apraclonidine testing showed a sensitivity of 84.6% and specificity of 92.3%. CONCLUSIONS: Digital pupillometry is an objective method for quantifying PLR. Baseline inter-eye difference in maximal pupil sizes and dilation lag measured by T75 was equally effective in the diagnosis of Horner syndrome compared to the reversal of anisocoria after apraclonidine instillation.
format Online
Article
Text
id pubmed-5456040
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54560402017-06-12 Efficacy of digital pupillometry for diagnosis of Horner syndrome Yoo, Yung Ju Yang, Hee Kyung Hwang, Jeong-Min PLoS One Research Article OBJECTIVES: To evaluate the efficacy of digital pupillometry in the diagnosis of anisocoria related to Horner syndrome in adult patients. DESIGN: Retrospective, observational, case control study. METHODS: Nineteen patients with unilateral Horner syndrome (Horner group) and age-matched controls of 30 healthy individuals with normal vision and neither optic nerve dysfunction nor pupillary abnormalities were included. Pupillary light reflex (PLR) of the Horner group and controls were measured by a dynamic pupillometer (PLR-200; NeurOptics Inc., Irvine, USA). Minimal and maximal (min/max) pupil diameters, latency, constriction ratio, constriction velocity, dilation velocity, and total time taken by the pupil to recover 75% of maximal pupil diameter (T75) were noted. PLR were measured at baseline in both groups and at 30–45 minutes later after 0.5% apraclonidine (Iopidine(®); Alcon Laboratories, Fort Worth, TX, USA) instillation in the Horner group. MAIN OUTCOME MEASURES: The PLR parameters in the affected eye and inter-eye difference before and after 0.5% apraclonidine instillation. RESULTS: In the Horner group, pupil diameters and T75 showed significant difference between the affected eye and unaffected contralateral eye at baseline (all P<0.00625). Compared to controls, inter-eye difference values of pupil diameters and T75 were significantly larger in the Horner group (all P<0.001). After 0.5% apraclonidine instillation, changes in pupil diameter and constriction ratio were significantly larger in the affected eye compared to the unaffected contralateral eye (all P<0.00625). The area under the receiver operating characteristic curves for diagnosing Horner syndrome were largest for baseline inter-eye difference in min/max pupil sizes (AUC = 0.975, 0.994), T75 (AUC = 0.838), and change in min/max pupil sizes after apraclonidine instillation (AUC = 0.923, 0.929, respectively). The diagnostic criteria for Horner syndrome relying on baseline pupillary measurements was defined as one of the two major findings; 1) smaller maximal pupil diameter in the affected eye with an inter-eye difference of > 0.5 mm, or 2) T75 > 2.61 seconds in the affected eye, which showed a sensitivity of 94.7% and specificity of 93.3%. The diagnostic accuracy of apraclonidine testing showed a sensitivity of 84.6% and specificity of 92.3%. CONCLUSIONS: Digital pupillometry is an objective method for quantifying PLR. Baseline inter-eye difference in maximal pupil sizes and dilation lag measured by T75 was equally effective in the diagnosis of Horner syndrome compared to the reversal of anisocoria after apraclonidine instillation. Public Library of Science 2017-06-02 /pmc/articles/PMC5456040/ /pubmed/28575101 http://dx.doi.org/10.1371/journal.pone.0178361 Text en © 2017 Yoo et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Yoo, Yung Ju
Yang, Hee Kyung
Hwang, Jeong-Min
Efficacy of digital pupillometry for diagnosis of Horner syndrome
title Efficacy of digital pupillometry for diagnosis of Horner syndrome
title_full Efficacy of digital pupillometry for diagnosis of Horner syndrome
title_fullStr Efficacy of digital pupillometry for diagnosis of Horner syndrome
title_full_unstemmed Efficacy of digital pupillometry for diagnosis of Horner syndrome
title_short Efficacy of digital pupillometry for diagnosis of Horner syndrome
title_sort efficacy of digital pupillometry for diagnosis of horner syndrome
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456040/
https://www.ncbi.nlm.nih.gov/pubmed/28575101
http://dx.doi.org/10.1371/journal.pone.0178361
work_keys_str_mv AT yooyungju efficacyofdigitalpupillometryfordiagnosisofhornersyndrome
AT yangheekyung efficacyofdigitalpupillometryfordiagnosisofhornersyndrome
AT hwangjeongmin efficacyofdigitalpupillometryfordiagnosisofhornersyndrome