Cargando…

Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method

Optical coherence tomography (OCT) is an established catheter-based imaging modality for the assessment of coronary artery disease and the guidance of stent placement during percutaneous coronary intervention. Manual analysis of large OCT datasets for vessel contours or stent struts detection is tim...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiastra, Claudio, Montin, Eros, Bologna, Marco, Migliori, Susanna, Aurigemma, Cristina, Burzotta, Francesco, Celi, Simona, Dubini, Gabriele, Migliavacca, Francesco, Mainardi, Luca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456060/
https://www.ncbi.nlm.nih.gov/pubmed/28574987
http://dx.doi.org/10.1371/journal.pone.0177495
_version_ 1783241163411554304
author Chiastra, Claudio
Montin, Eros
Bologna, Marco
Migliori, Susanna
Aurigemma, Cristina
Burzotta, Francesco
Celi, Simona
Dubini, Gabriele
Migliavacca, Francesco
Mainardi, Luca
author_facet Chiastra, Claudio
Montin, Eros
Bologna, Marco
Migliori, Susanna
Aurigemma, Cristina
Burzotta, Francesco
Celi, Simona
Dubini, Gabriele
Migliavacca, Francesco
Mainardi, Luca
author_sort Chiastra, Claudio
collection PubMed
description Optical coherence tomography (OCT) is an established catheter-based imaging modality for the assessment of coronary artery disease and the guidance of stent placement during percutaneous coronary intervention. Manual analysis of large OCT datasets for vessel contours or stent struts detection is time-consuming and unsuitable for real-time applications. In this study, a fully automatic method was developed for detection of both vessel contours and stent struts. The method was applied to in vitro OCT scans of eight stented silicone bifurcation phantoms for validation purposes. The proposed algorithm comprised four main steps, namely pre-processing, lumen border detection, stent strut detection, and three-dimensional point cloud creation. The algorithm was validated against manual segmentation performed by two independent image readers. Linear regression showed good agreement between automatic and manual segmentations in terms of lumen area (r>0.99). No statistically significant differences in the number of detected struts were found between the segmentations. Mean values of similarity indexes were >95% and >85% for the lumen and stent detection, respectively. Stent point clouds of two selected cases, obtained after OCT image processing, were compared to the centerline points of the corresponding stent reconstructions from micro computed tomography, used as ground-truth. Quantitative comparison between the corresponding stent points resulted in median values of ~150 μm and ~40 μm for the total and radial distances of both cases, respectively. The repeatability of the detection method was investigated by calculating the lumen volume and the mean number of detected struts per frame for seven repeated OCT scans of one selected case. Results showed low deviation of values from the median for both analyzed quantities. In conclusion, this study presents a robust automatic method for detection of lumen contours and stent struts from OCT as supported by focused validation against both manual segmentation and micro computed tomography and by good repeatability.
format Online
Article
Text
id pubmed-5456060
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54560602017-06-12 Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method Chiastra, Claudio Montin, Eros Bologna, Marco Migliori, Susanna Aurigemma, Cristina Burzotta, Francesco Celi, Simona Dubini, Gabriele Migliavacca, Francesco Mainardi, Luca PLoS One Research Article Optical coherence tomography (OCT) is an established catheter-based imaging modality for the assessment of coronary artery disease and the guidance of stent placement during percutaneous coronary intervention. Manual analysis of large OCT datasets for vessel contours or stent struts detection is time-consuming and unsuitable for real-time applications. In this study, a fully automatic method was developed for detection of both vessel contours and stent struts. The method was applied to in vitro OCT scans of eight stented silicone bifurcation phantoms for validation purposes. The proposed algorithm comprised four main steps, namely pre-processing, lumen border detection, stent strut detection, and three-dimensional point cloud creation. The algorithm was validated against manual segmentation performed by two independent image readers. Linear regression showed good agreement between automatic and manual segmentations in terms of lumen area (r>0.99). No statistically significant differences in the number of detected struts were found between the segmentations. Mean values of similarity indexes were >95% and >85% for the lumen and stent detection, respectively. Stent point clouds of two selected cases, obtained after OCT image processing, were compared to the centerline points of the corresponding stent reconstructions from micro computed tomography, used as ground-truth. Quantitative comparison between the corresponding stent points resulted in median values of ~150 μm and ~40 μm for the total and radial distances of both cases, respectively. The repeatability of the detection method was investigated by calculating the lumen volume and the mean number of detected struts per frame for seven repeated OCT scans of one selected case. Results showed low deviation of values from the median for both analyzed quantities. In conclusion, this study presents a robust automatic method for detection of lumen contours and stent struts from OCT as supported by focused validation against both manual segmentation and micro computed tomography and by good repeatability. Public Library of Science 2017-06-02 /pmc/articles/PMC5456060/ /pubmed/28574987 http://dx.doi.org/10.1371/journal.pone.0177495 Text en © 2017 Chiastra et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Chiastra, Claudio
Montin, Eros
Bologna, Marco
Migliori, Susanna
Aurigemma, Cristina
Burzotta, Francesco
Celi, Simona
Dubini, Gabriele
Migliavacca, Francesco
Mainardi, Luca
Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
title Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
title_full Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
title_fullStr Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
title_full_unstemmed Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
title_short Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
title_sort reconstruction of stented coronary arteries from optical coherence tomography images: feasibility, validation, and repeatability of a segmentation method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456060/
https://www.ncbi.nlm.nih.gov/pubmed/28574987
http://dx.doi.org/10.1371/journal.pone.0177495
work_keys_str_mv AT chiastraclaudio reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT montineros reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT bolognamarco reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT migliorisusanna reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT aurigemmacristina reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT burzottafrancesco reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT celisimona reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT dubinigabriele reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT migliavaccafrancesco reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod
AT mainardiluca reconstructionofstentedcoronaryarteriesfromopticalcoherencetomographyimagesfeasibilityvalidationandrepeatabilityofasegmentationmethod