Cargando…

An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings

In this study, surface properties of Ti-6Al-4V alloy coated with hydroxyapatite coatings were investigated. Wear resistance and fatigue behaviour of samples with coating thicknesses of 10 and 50 µm as well as uncoated samples were examined. Wear experiments demonstrated that the friction factor of t...

Descripción completa

Detalles Bibliográficos
Autores principales: Oskouei, Reza H, Fallahnezhad, Khosro, Kuppusami, Sushmitha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456493/
https://www.ncbi.nlm.nih.gov/pubmed/28787911
http://dx.doi.org/10.3390/ma9020111
_version_ 1783241277613015040
author Oskouei, Reza H
Fallahnezhad, Khosro
Kuppusami, Sushmitha
author_facet Oskouei, Reza H
Fallahnezhad, Khosro
Kuppusami, Sushmitha
author_sort Oskouei, Reza H
collection PubMed
description In this study, surface properties of Ti-6Al-4V alloy coated with hydroxyapatite coatings were investigated. Wear resistance and fatigue behaviour of samples with coating thicknesses of 10 and 50 µm as well as uncoated samples were examined. Wear experiments demonstrated that the friction factor of the uncoated titanium decreased from 0.31 to 0.06, through a fluctuating trend, after 50 cycles of wear tests. However, the friction factor of both the coated samples (10 and 50 µm) gradually decreased from 0.20 to 0.12 after 50 cycles. At the end of the 50th cycle, the penetration depth of the 10 and 50 µm coated samples were 7.69 and 6.06 µm, respectively. Fatigue tests showed that hydroxyapatite coatings could improve fatigue life of a notched Ti-6Al-4V member in both low and high cycle fatigue zones. It was understood, from fractography of the fracture surfaces, that the fatigue zone of the uncoated specimens was generally smaller in comparison with that of the coated specimens. No significant difference was observed between the fatigue life of coated specimens with 10 and 50 µm thicknesses.
format Online
Article
Text
id pubmed-5456493
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54564932017-07-28 An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings Oskouei, Reza H Fallahnezhad, Khosro Kuppusami, Sushmitha Materials (Basel) Article In this study, surface properties of Ti-6Al-4V alloy coated with hydroxyapatite coatings were investigated. Wear resistance and fatigue behaviour of samples with coating thicknesses of 10 and 50 µm as well as uncoated samples were examined. Wear experiments demonstrated that the friction factor of the uncoated titanium decreased from 0.31 to 0.06, through a fluctuating trend, after 50 cycles of wear tests. However, the friction factor of both the coated samples (10 and 50 µm) gradually decreased from 0.20 to 0.12 after 50 cycles. At the end of the 50th cycle, the penetration depth of the 10 and 50 µm coated samples were 7.69 and 6.06 µm, respectively. Fatigue tests showed that hydroxyapatite coatings could improve fatigue life of a notched Ti-6Al-4V member in both low and high cycle fatigue zones. It was understood, from fractography of the fracture surfaces, that the fatigue zone of the uncoated specimens was generally smaller in comparison with that of the coated specimens. No significant difference was observed between the fatigue life of coated specimens with 10 and 50 µm thicknesses. MDPI 2016-02-16 /pmc/articles/PMC5456493/ /pubmed/28787911 http://dx.doi.org/10.3390/ma9020111 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oskouei, Reza H
Fallahnezhad, Khosro
Kuppusami, Sushmitha
An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
title An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
title_full An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
title_fullStr An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
title_full_unstemmed An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
title_short An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
title_sort investigation on the wear resistance and fatigue behaviour of ti-6al-4v notched members coated with hydroxyapatite coatings
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456493/
https://www.ncbi.nlm.nih.gov/pubmed/28787911
http://dx.doi.org/10.3390/ma9020111
work_keys_str_mv AT oskoueirezah aninvestigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings
AT fallahnezhadkhosro aninvestigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings
AT kuppusamisushmitha aninvestigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings
AT oskoueirezah investigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings
AT fallahnezhadkhosro investigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings
AT kuppusamisushmitha investigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings