Cargando…
An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings
In this study, surface properties of Ti-6Al-4V alloy coated with hydroxyapatite coatings were investigated. Wear resistance and fatigue behaviour of samples with coating thicknesses of 10 and 50 µm as well as uncoated samples were examined. Wear experiments demonstrated that the friction factor of t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456493/ https://www.ncbi.nlm.nih.gov/pubmed/28787911 http://dx.doi.org/10.3390/ma9020111 |
_version_ | 1783241277613015040 |
---|---|
author | Oskouei, Reza H Fallahnezhad, Khosro Kuppusami, Sushmitha |
author_facet | Oskouei, Reza H Fallahnezhad, Khosro Kuppusami, Sushmitha |
author_sort | Oskouei, Reza H |
collection | PubMed |
description | In this study, surface properties of Ti-6Al-4V alloy coated with hydroxyapatite coatings were investigated. Wear resistance and fatigue behaviour of samples with coating thicknesses of 10 and 50 µm as well as uncoated samples were examined. Wear experiments demonstrated that the friction factor of the uncoated titanium decreased from 0.31 to 0.06, through a fluctuating trend, after 50 cycles of wear tests. However, the friction factor of both the coated samples (10 and 50 µm) gradually decreased from 0.20 to 0.12 after 50 cycles. At the end of the 50th cycle, the penetration depth of the 10 and 50 µm coated samples were 7.69 and 6.06 µm, respectively. Fatigue tests showed that hydroxyapatite coatings could improve fatigue life of a notched Ti-6Al-4V member in both low and high cycle fatigue zones. It was understood, from fractography of the fracture surfaces, that the fatigue zone of the uncoated specimens was generally smaller in comparison with that of the coated specimens. No significant difference was observed between the fatigue life of coated specimens with 10 and 50 µm thicknesses. |
format | Online Article Text |
id | pubmed-5456493 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-54564932017-07-28 An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings Oskouei, Reza H Fallahnezhad, Khosro Kuppusami, Sushmitha Materials (Basel) Article In this study, surface properties of Ti-6Al-4V alloy coated with hydroxyapatite coatings were investigated. Wear resistance and fatigue behaviour of samples with coating thicknesses of 10 and 50 µm as well as uncoated samples were examined. Wear experiments demonstrated that the friction factor of the uncoated titanium decreased from 0.31 to 0.06, through a fluctuating trend, after 50 cycles of wear tests. However, the friction factor of both the coated samples (10 and 50 µm) gradually decreased from 0.20 to 0.12 after 50 cycles. At the end of the 50th cycle, the penetration depth of the 10 and 50 µm coated samples were 7.69 and 6.06 µm, respectively. Fatigue tests showed that hydroxyapatite coatings could improve fatigue life of a notched Ti-6Al-4V member in both low and high cycle fatigue zones. It was understood, from fractography of the fracture surfaces, that the fatigue zone of the uncoated specimens was generally smaller in comparison with that of the coated specimens. No significant difference was observed between the fatigue life of coated specimens with 10 and 50 µm thicknesses. MDPI 2016-02-16 /pmc/articles/PMC5456493/ /pubmed/28787911 http://dx.doi.org/10.3390/ma9020111 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons by Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Oskouei, Reza H Fallahnezhad, Khosro Kuppusami, Sushmitha An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings |
title | An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings |
title_full | An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings |
title_fullStr | An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings |
title_full_unstemmed | An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings |
title_short | An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings |
title_sort | investigation on the wear resistance and fatigue behaviour of ti-6al-4v notched members coated with hydroxyapatite coatings |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456493/ https://www.ncbi.nlm.nih.gov/pubmed/28787911 http://dx.doi.org/10.3390/ma9020111 |
work_keys_str_mv | AT oskoueirezah aninvestigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings AT fallahnezhadkhosro aninvestigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings AT kuppusamisushmitha aninvestigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings AT oskoueirezah investigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings AT fallahnezhadkhosro investigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings AT kuppusamisushmitha investigationonthewearresistanceandfatiguebehaviourofti6al4vnotchedmemberscoatedwithhydroxyapatitecoatings |