Cargando…
Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters
Titania nanotube-based local drug delivery is an attractive strategy for combating implant-associated infection. In our previous study, we demonstrated that the gentamicin-loaded nanotubes could dramatically inhibit bacterial adhesion and biofilm formation on implant surfaces. Considering the overus...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456703/ https://www.ncbi.nlm.nih.gov/pubmed/28773281 http://dx.doi.org/10.3390/ma9030155 |
_version_ | 1783241350814105600 |
---|---|
author | Lin, Wen-tao Zhang, Yi-yuan Tan, Hong-lue Ao, Hai-yong Duan, Zhao-ling He, Guo Tang, Ting-ting |
author_facet | Lin, Wen-tao Zhang, Yi-yuan Tan, Hong-lue Ao, Hai-yong Duan, Zhao-ling He, Guo Tang, Ting-ting |
author_sort | Lin, Wen-tao |
collection | PubMed |
description | Titania nanotube-based local drug delivery is an attractive strategy for combating implant-associated infection. In our previous study, we demonstrated that the gentamicin-loaded nanotubes could dramatically inhibit bacterial adhesion and biofilm formation on implant surfaces. Considering the overuse of antibiotics may lead to the evolution of antibiotic-resistant bacteria, we synthesized a new quaternized chitosan derivative (hydroxypropyltrimethyl ammonium chloride chitosan, HACC) with a 27% degree of substitution (DS; referred to as 27% HACC) that had a strong antibacterial activity and simultaneously good biocompatibility with osteogenic cells. Titania nanotubes with various diameters (80, 120, 160, and 200 nm) and 200 nm length were loaded with 2 mg of HACC using a lyophilization method and vacuum drying. Two standard strain, methicillin-resistant Staphylococcus aureus (American Type Culture Collection 43300) and Staphylococcus epidermidis (American Type Culture Collection 35984), and two clinical isolates, S. aureus 376 and S. epidermidis 389, were selected to investigate the bacterial adhesion at 6 h and biofilm formation at 24, 48, and 72 h on the HACC-loaded nanotubes (NT-H) using the spread plate method, confocal laser scanning microscopy (CLSM), and scanning electron microscopy (SEM). Smooth titanium (Smooth Ti) was also investigated and compared. We found that NT-H could significantly inhibit bacterial adhesion and biofilm formation on its surface compared with Smooth Ti, and the NT-H with 160 nm and 200 nm diameters had stronger antibacterial activity because of the extended HACC release time of NT-H with larger diameters. Therefore, NT-H can significantly improve the antibacterial ability of orthopedic implants and provide a promising strategy to prevent implant-associated infections. |
format | Online Article Text |
id | pubmed-5456703 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-54567032017-07-28 Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters Lin, Wen-tao Zhang, Yi-yuan Tan, Hong-lue Ao, Hai-yong Duan, Zhao-ling He, Guo Tang, Ting-ting Materials (Basel) Article Titania nanotube-based local drug delivery is an attractive strategy for combating implant-associated infection. In our previous study, we demonstrated that the gentamicin-loaded nanotubes could dramatically inhibit bacterial adhesion and biofilm formation on implant surfaces. Considering the overuse of antibiotics may lead to the evolution of antibiotic-resistant bacteria, we synthesized a new quaternized chitosan derivative (hydroxypropyltrimethyl ammonium chloride chitosan, HACC) with a 27% degree of substitution (DS; referred to as 27% HACC) that had a strong antibacterial activity and simultaneously good biocompatibility with osteogenic cells. Titania nanotubes with various diameters (80, 120, 160, and 200 nm) and 200 nm length were loaded with 2 mg of HACC using a lyophilization method and vacuum drying. Two standard strain, methicillin-resistant Staphylococcus aureus (American Type Culture Collection 43300) and Staphylococcus epidermidis (American Type Culture Collection 35984), and two clinical isolates, S. aureus 376 and S. epidermidis 389, were selected to investigate the bacterial adhesion at 6 h and biofilm formation at 24, 48, and 72 h on the HACC-loaded nanotubes (NT-H) using the spread plate method, confocal laser scanning microscopy (CLSM), and scanning electron microscopy (SEM). Smooth titanium (Smooth Ti) was also investigated and compared. We found that NT-H could significantly inhibit bacterial adhesion and biofilm formation on its surface compared with Smooth Ti, and the NT-H with 160 nm and 200 nm diameters had stronger antibacterial activity because of the extended HACC release time of NT-H with larger diameters. Therefore, NT-H can significantly improve the antibacterial ability of orthopedic implants and provide a promising strategy to prevent implant-associated infections. MDPI 2016-03-03 /pmc/articles/PMC5456703/ /pubmed/28773281 http://dx.doi.org/10.3390/ma9030155 Text en © 2016 by the authors; Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lin, Wen-tao Zhang, Yi-yuan Tan, Hong-lue Ao, Hai-yong Duan, Zhao-ling He, Guo Tang, Ting-ting Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters |
title | Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters |
title_full | Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters |
title_fullStr | Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters |
title_full_unstemmed | Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters |
title_short | Inhibited Bacterial Adhesion and Biofilm Formation on Quaternized Chitosan-Loaded Titania Nanotubes with Various Diameters |
title_sort | inhibited bacterial adhesion and biofilm formation on quaternized chitosan-loaded titania nanotubes with various diameters |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5456703/ https://www.ncbi.nlm.nih.gov/pubmed/28773281 http://dx.doi.org/10.3390/ma9030155 |
work_keys_str_mv | AT linwentao inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters AT zhangyiyuan inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters AT tanhonglue inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters AT aohaiyong inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters AT duanzhaoling inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters AT heguo inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters AT tangtingting inhibitedbacterialadhesionandbiofilmformationonquaternizedchitosanloadedtitaniananotubeswithvariousdiameters |