Cargando…

Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery

BACKGROUND: The purpose of our study is to develop the arthroscopic autofluorescence imaging (AFI) system to improve the visualization during arthroscopic surgery by real-time enhancing the contrast between joint structures with autofluorescence imaging. Its validity was evaluated around the arthros...

Descripción completa

Detalles Bibliográficos
Autores principales: Nguyen, Duy Tan, van Horssen, Pepijn, Derriks, Hans, van de Giessen, Martijn, van Leeuwen, Ton
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5457390/
https://www.ncbi.nlm.nih.gov/pubmed/28577187
http://dx.doi.org/10.1186/s40634-017-0094-4
_version_ 1783241524260110336
author Nguyen, Duy Tan
van Horssen, Pepijn
Derriks, Hans
van de Giessen, Martijn
van Leeuwen, Ton
author_facet Nguyen, Duy Tan
van Horssen, Pepijn
Derriks, Hans
van de Giessen, Martijn
van Leeuwen, Ton
author_sort Nguyen, Duy Tan
collection PubMed
description BACKGROUND: The purpose of our study is to develop the arthroscopic autofluorescence imaging (AFI) system to improve the visualization during arthroscopic surgery by real-time enhancing the contrast between joint structures with autofluorescence imaging. Its validity was evaluated around the arthroscopic anterior cruciate ligament (ACL) reconstruction, specifically improving the contrast between the femoral insertion site and its background. The feasibility of the AFI system was validated with bovine and human knees. The spectral responses of the femoral insertion site and its surrounding bone and cartilage were measured with a fluorospectrometer. A prototype of the AFI system was developed based on the spectral responses (SR) and test images of the insertion site. The accuracy was validated by evaluating the overlap between manually segmented insertion sites on the white light color images and on the corresponding spectral unmixed autofluorescence images. The final prototype of the AFI system was tested during arthroscopy in cadaveric knees. RESULTS: The results showed that the joint structures have different SRs. Spectral unmixing enabled separation of the SRs and improved the contrast between the joint structures. The agreement between visible light and autofluorescence ligament insertions had a mean Dice coefficient of 0.84 and the mean Dice coefficient of the interobserver variability for visible light imaging was 0.85. CONCLUSIONS: We have shown that the femoral insertion site can be accurately visualized with autofluorescence imaging combined with spectral unmixing. The AFI system demonstrates the feasibility of real-time and subject-specific visualization of the femoral insertion site which can facilitate anatomic ACL reconstruction. In addition, the AFI system can facilitate arthroscopic procedures in other joints and can also be used as a diagnostic tool. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s40634-017-0094-4) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5457390
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-54573902017-06-16 Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery Nguyen, Duy Tan van Horssen, Pepijn Derriks, Hans van de Giessen, Martijn van Leeuwen, Ton J Exp Orthop Research BACKGROUND: The purpose of our study is to develop the arthroscopic autofluorescence imaging (AFI) system to improve the visualization during arthroscopic surgery by real-time enhancing the contrast between joint structures with autofluorescence imaging. Its validity was evaluated around the arthroscopic anterior cruciate ligament (ACL) reconstruction, specifically improving the contrast between the femoral insertion site and its background. The feasibility of the AFI system was validated with bovine and human knees. The spectral responses of the femoral insertion site and its surrounding bone and cartilage were measured with a fluorospectrometer. A prototype of the AFI system was developed based on the spectral responses (SR) and test images of the insertion site. The accuracy was validated by evaluating the overlap between manually segmented insertion sites on the white light color images and on the corresponding spectral unmixed autofluorescence images. The final prototype of the AFI system was tested during arthroscopy in cadaveric knees. RESULTS: The results showed that the joint structures have different SRs. Spectral unmixing enabled separation of the SRs and improved the contrast between the joint structures. The agreement between visible light and autofluorescence ligament insertions had a mean Dice coefficient of 0.84 and the mean Dice coefficient of the interobserver variability for visible light imaging was 0.85. CONCLUSIONS: We have shown that the femoral insertion site can be accurately visualized with autofluorescence imaging combined with spectral unmixing. The AFI system demonstrates the feasibility of real-time and subject-specific visualization of the femoral insertion site which can facilitate anatomic ACL reconstruction. In addition, the AFI system can facilitate arthroscopic procedures in other joints and can also be used as a diagnostic tool. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s40634-017-0094-4) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2017-06-02 /pmc/articles/PMC5457390/ /pubmed/28577187 http://dx.doi.org/10.1186/s40634-017-0094-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Nguyen, Duy Tan
van Horssen, Pepijn
Derriks, Hans
van de Giessen, Martijn
van Leeuwen, Ton
Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
title Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
title_full Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
title_fullStr Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
title_full_unstemmed Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
title_short Autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
title_sort autofluorescence imaging for improved visualization of joint structures during arthroscopic surgery
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5457390/
https://www.ncbi.nlm.nih.gov/pubmed/28577187
http://dx.doi.org/10.1186/s40634-017-0094-4
work_keys_str_mv AT nguyenduytan autofluorescenceimagingforimprovedvisualizationofjointstructuresduringarthroscopicsurgery
AT vanhorssenpepijn autofluorescenceimagingforimprovedvisualizationofjointstructuresduringarthroscopicsurgery
AT derrikshans autofluorescenceimagingforimprovedvisualizationofjointstructuresduringarthroscopicsurgery
AT vandegiessenmartijn autofluorescenceimagingforimprovedvisualizationofjointstructuresduringarthroscopicsurgery
AT vanleeuwenton autofluorescenceimagingforimprovedvisualizationofjointstructuresduringarthroscopicsurgery