Cargando…

A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices

OBJECTIVES: The fractional flow reserve (FFR) is an index of the severity of coronary stenosis that has been clinically validated in several studies. The instantaneous wave-free ratio (iFR) and the resting distal coronary artery pressure/aortic pressure (Pd/Pa) are nonhyperemic pressure-derived indi...

Descripción completa

Detalles Bibliográficos
Autores principales: Shiode, Nobuo, Okimoto, Tomokazu, Tamekiyo, Hiromichi, Kawase, Tomoharu, Yamane, Kenichi, Kagawa, Yuzo, Fujii, Yuto, Ueda, Yusuke, Hironobe, Naoya, Kato, Yasuko, Hayashi, Yasuhiko
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society of Internal Medicine 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5457916/
https://www.ncbi.nlm.nih.gov/pubmed/28381739
http://dx.doi.org/10.2169/internalmedicine.56.7857
_version_ 1783241638895681536
author Shiode, Nobuo
Okimoto, Tomokazu
Tamekiyo, Hiromichi
Kawase, Tomoharu
Yamane, Kenichi
Kagawa, Yuzo
Fujii, Yuto
Ueda, Yusuke
Hironobe, Naoya
Kato, Yasuko
Hayashi, Yasuhiko
author_facet Shiode, Nobuo
Okimoto, Tomokazu
Tamekiyo, Hiromichi
Kawase, Tomoharu
Yamane, Kenichi
Kagawa, Yuzo
Fujii, Yuto
Ueda, Yusuke
Hironobe, Naoya
Kato, Yasuko
Hayashi, Yasuhiko
author_sort Shiode, Nobuo
collection PubMed
description OBJECTIVES: The fractional flow reserve (FFR) is an index of the severity of coronary stenosis that has been clinically validated in several studies. The instantaneous wave-free ratio (iFR) and the resting distal coronary artery pressure/aortic pressure (Pd/Pa) are nonhyperemic pressure-derived indices of the severity of stenosis. This study sought to examine the diagnostic accuracy of the iFR and resting Pd/Pa with respect to hyperemic FFR. METHODS: Following an intracoronary injection of papaverine, the iFR, resting Pd/Pa, and FFR were continuously measured in 123 lesions in 103 patients with stable coronary disease. RESULTS: The iFR and resting Pd/Pa values were strongly correlated with the FFR (R=0.794, p<0.001, R=0.832, p<0.0001, respectively). A receiver operator curve (ROC) analysis revealed that the optimal iFR cut-off value for predicting an FFR of <0.80 was 0.89 (AUC 0.901, sensitivity 84.1%, specificity 80.0%, positive predictive value 69.8%, negative predictive value 90.0%, diagnostic accuracy 81.3%), while the optimal resting Pd/Pa cut-off value was 0.92 (AUC 0.925, sensitivity 90.9%, specificity 78.5%, positive predictive value 70.2%, negative predictive value 93.9%, diagnostic accuracy 82.9%). The lesions with an iFR value of ≤0.89 and a Pd/Pa value of ≤0.92 were defined as double-positive lesions, while the lesions with an iFR value of >0.89 and a Pd/Pa value of >0.92 were defined as double-negative lesions. In these 109 lesions, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 92.3%, 82.9%, 75.0%, 95.1%, and 86.2%, respectively. CONCLUSION: This analysis demonstrated that the iFR and resting Pd/Pa were strongly correlated with the FFR and that the diagnostic accuracy of the iFR was similar to that of the resting Pd/Pa. The diagnostic accuracy can be improved with the use of both the iFR and the resting Pd/Pa.
format Online
Article
Text
id pubmed-5457916
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher The Japanese Society of Internal Medicine
record_format MEDLINE/PubMed
spelling pubmed-54579162017-06-08 A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices Shiode, Nobuo Okimoto, Tomokazu Tamekiyo, Hiromichi Kawase, Tomoharu Yamane, Kenichi Kagawa, Yuzo Fujii, Yuto Ueda, Yusuke Hironobe, Naoya Kato, Yasuko Hayashi, Yasuhiko Intern Med Original Article OBJECTIVES: The fractional flow reserve (FFR) is an index of the severity of coronary stenosis that has been clinically validated in several studies. The instantaneous wave-free ratio (iFR) and the resting distal coronary artery pressure/aortic pressure (Pd/Pa) are nonhyperemic pressure-derived indices of the severity of stenosis. This study sought to examine the diagnostic accuracy of the iFR and resting Pd/Pa with respect to hyperemic FFR. METHODS: Following an intracoronary injection of papaverine, the iFR, resting Pd/Pa, and FFR were continuously measured in 123 lesions in 103 patients with stable coronary disease. RESULTS: The iFR and resting Pd/Pa values were strongly correlated with the FFR (R=0.794, p<0.001, R=0.832, p<0.0001, respectively). A receiver operator curve (ROC) analysis revealed that the optimal iFR cut-off value for predicting an FFR of <0.80 was 0.89 (AUC 0.901, sensitivity 84.1%, specificity 80.0%, positive predictive value 69.8%, negative predictive value 90.0%, diagnostic accuracy 81.3%), while the optimal resting Pd/Pa cut-off value was 0.92 (AUC 0.925, sensitivity 90.9%, specificity 78.5%, positive predictive value 70.2%, negative predictive value 93.9%, diagnostic accuracy 82.9%). The lesions with an iFR value of ≤0.89 and a Pd/Pa value of ≤0.92 were defined as double-positive lesions, while the lesions with an iFR value of >0.89 and a Pd/Pa value of >0.92 were defined as double-negative lesions. In these 109 lesions, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 92.3%, 82.9%, 75.0%, 95.1%, and 86.2%, respectively. CONCLUSION: This analysis demonstrated that the iFR and resting Pd/Pa were strongly correlated with the FFR and that the diagnostic accuracy of the iFR was similar to that of the resting Pd/Pa. The diagnostic accuracy can be improved with the use of both the iFR and the resting Pd/Pa. The Japanese Society of Internal Medicine 2017-04-01 /pmc/articles/PMC5457916/ /pubmed/28381739 http://dx.doi.org/10.2169/internalmedicine.56.7857 Text en Copyright © 2017 by The Japanese Society of Internal Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/ The Internal Medicine is an Open Access article distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Shiode, Nobuo
Okimoto, Tomokazu
Tamekiyo, Hiromichi
Kawase, Tomoharu
Yamane, Kenichi
Kagawa, Yuzo
Fujii, Yuto
Ueda, Yusuke
Hironobe, Naoya
Kato, Yasuko
Hayashi, Yasuhiko
A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices
title A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices
title_full A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices
title_fullStr A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices
title_full_unstemmed A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices
title_short A Comparison between the Instantaneous Wave-free Ratio and Resting Distal Coronary Artery Pressure/Aortic Pressure and the Fractional Flow Reserve: The Diagnostic Accuracy Can Be Improved by the Use of both Indices
title_sort comparison between the instantaneous wave-free ratio and resting distal coronary artery pressure/aortic pressure and the fractional flow reserve: the diagnostic accuracy can be improved by the use of both indices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5457916/
https://www.ncbi.nlm.nih.gov/pubmed/28381739
http://dx.doi.org/10.2169/internalmedicine.56.7857
work_keys_str_mv AT shiodenobuo acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT okimototomokazu acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT tamekiyohiromichi acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT kawasetomoharu acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT yamanekenichi acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT kagawayuzo acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT fujiiyuto acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT uedayusuke acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT hironobenaoya acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT katoyasuko acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT hayashiyasuhiko acomparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT shiodenobuo comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT okimototomokazu comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT tamekiyohiromichi comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT kawasetomoharu comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT yamanekenichi comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT kagawayuzo comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT fujiiyuto comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT uedayusuke comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT hironobenaoya comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT katoyasuko comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices
AT hayashiyasuhiko comparisonbetweentheinstantaneouswavefreeratioandrestingdistalcoronaryarterypressureaorticpressureandthefractionalflowreservethediagnosticaccuracycanbeimprovedbytheuseofbothindices