Cargando…

Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging

Single isotope 99mTc single-photon emission computed tomography-myocardial perfusion imaging (SPECT-MPI) is the most commonly used protocol for nuclear stress testing. Transient ischemic dilation of the left ventricle (TID) has been considered a specific marker of severe coronary artery disease (CAD...

Descripción completa

Detalles Bibliográficos
Autores principales: Rubio, Manolo, Dias, Andre, Koshkelashvili, Nikoloz, Codolosa, Jose N., Jalife-Bucay, Mauricio, Rodriguez-Ziccardi, Mary, Amanullah, Aman M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460306/
https://www.ncbi.nlm.nih.gov/pubmed/28670181
http://dx.doi.org/10.4103/1450-1147.207282
_version_ 1783242143162171392
author Rubio, Manolo
Dias, Andre
Koshkelashvili, Nikoloz
Codolosa, Jose N.
Jalife-Bucay, Mauricio
Rodriguez-Ziccardi, Mary
Amanullah, Aman M.
author_facet Rubio, Manolo
Dias, Andre
Koshkelashvili, Nikoloz
Codolosa, Jose N.
Jalife-Bucay, Mauricio
Rodriguez-Ziccardi, Mary
Amanullah, Aman M.
author_sort Rubio, Manolo
collection PubMed
description Single isotope 99mTc single-photon emission computed tomography-myocardial perfusion imaging (SPECT-MPI) is the most commonly used protocol for nuclear stress testing. Transient ischemic dilation of the left ventricle (TID) has been considered a specific marker of severe coronary artery disease (CAD). Recent publications have questioned the clinical utility of TID, specifically with regadenoson as a stressor and 4DM-SPECT software for TID analysis. These findings have not been demonstrated using other imaging packages. The goal of our study was to establish the TID threshold in the identification of Multi-vessel CAD using Quantitative Perfusion SPECT (QPS) software. Included in this study are 190 patients that had undergone regadenoson-stress, same day, single-isotope 99mTc MPI and had a coronary angiography within a designated 3-month period. QPS (Cedars-Sinai, LA, CA) automated image analysis software was used to calculate TID ratios which were compared across different CAD categories. Coronary angiograms were reviewed to identify both obstructive and nonobstructive CAD. The mean TID for patients with nonobstructive CAD (n = 91) was 1.02 ± 0.11, and the threshold for TID was 1.24. A receiver operating characteristic curve showed that TID had a poor discriminatory capacity to identify MVD (area under the curve 0.58) with a sensitivity of 3% and a specificity of 97%. In our study with regadenoson MPI in a predominantly African-American population, TID was found to be a poor predictor of MVD using QPS software. The reason is unclear but possibly related to the significant decline in the prevalence of severe CAD in the area where our study took place.
format Online
Article
Text
id pubmed-5460306
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-54603062017-07-01 Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging Rubio, Manolo Dias, Andre Koshkelashvili, Nikoloz Codolosa, Jose N. Jalife-Bucay, Mauricio Rodriguez-Ziccardi, Mary Amanullah, Aman M. World J Nucl Med Original Article Single isotope 99mTc single-photon emission computed tomography-myocardial perfusion imaging (SPECT-MPI) is the most commonly used protocol for nuclear stress testing. Transient ischemic dilation of the left ventricle (TID) has been considered a specific marker of severe coronary artery disease (CAD). Recent publications have questioned the clinical utility of TID, specifically with regadenoson as a stressor and 4DM-SPECT software for TID analysis. These findings have not been demonstrated using other imaging packages. The goal of our study was to establish the TID threshold in the identification of Multi-vessel CAD using Quantitative Perfusion SPECT (QPS) software. Included in this study are 190 patients that had undergone regadenoson-stress, same day, single-isotope 99mTc MPI and had a coronary angiography within a designated 3-month period. QPS (Cedars-Sinai, LA, CA) automated image analysis software was used to calculate TID ratios which were compared across different CAD categories. Coronary angiograms were reviewed to identify both obstructive and nonobstructive CAD. The mean TID for patients with nonobstructive CAD (n = 91) was 1.02 ± 0.11, and the threshold for TID was 1.24. A receiver operating characteristic curve showed that TID had a poor discriminatory capacity to identify MVD (area under the curve 0.58) with a sensitivity of 3% and a specificity of 97%. In our study with regadenoson MPI in a predominantly African-American population, TID was found to be a poor predictor of MVD using QPS software. The reason is unclear but possibly related to the significant decline in the prevalence of severe CAD in the area where our study took place. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5460306/ /pubmed/28670181 http://dx.doi.org/10.4103/1450-1147.207282 Text en Copyright: © 2017 World Journal of Nuclear Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Rubio, Manolo
Dias, Andre
Koshkelashvili, Nikoloz
Codolosa, Jose N.
Jalife-Bucay, Mauricio
Rodriguez-Ziccardi, Mary
Amanullah, Aman M.
Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging
title Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging
title_full Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging
title_fullStr Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging
title_full_unstemmed Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging
title_short Transient Ischemic Dilation Ratio in Regadenoson, Single Isotope Gated Single-photon Emission Computed Tomography Myocardial Perfusion Imaging
title_sort transient ischemic dilation ratio in regadenoson, single isotope gated single-photon emission computed tomography myocardial perfusion imaging
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460306/
https://www.ncbi.nlm.nih.gov/pubmed/28670181
http://dx.doi.org/10.4103/1450-1147.207282
work_keys_str_mv AT rubiomanolo transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging
AT diasandre transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging
AT koshkelashvilinikoloz transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging
AT codolosajosen transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging
AT jalifebucaymauricio transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging
AT rodriguezziccardimary transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging
AT amanullahamanm transientischemicdilationratioinregadenosonsingleisotopegatedsinglephotonemissioncomputedtomographymyocardialperfusionimaging