Cargando…

The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography

OBJECTIVES: To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR) techniques on the iodine dose in coronary CTA. METHODS: Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage a...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Cauteren, Toon, Van Gompel, Gert, Tanaka, Kaoru, Verdries, Douwe E., Belsack, Dries, Nieboer, Koenraad H., Willekens, Inneke, Evans, Paul, Macholl, Sven, Verfaillie, Guy, Droogmans, Steven, de Mey, Johan, Buls, Nico
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460391/
https://www.ncbi.nlm.nih.gov/pubmed/28620616
http://dx.doi.org/10.1155/2017/2476171
_version_ 1783242161454579712
author Van Cauteren, Toon
Van Gompel, Gert
Tanaka, Kaoru
Verdries, Douwe E.
Belsack, Dries
Nieboer, Koenraad H.
Willekens, Inneke
Evans, Paul
Macholl, Sven
Verfaillie, Guy
Droogmans, Steven
de Mey, Johan
Buls, Nico
author_facet Van Cauteren, Toon
Van Gompel, Gert
Tanaka, Kaoru
Verdries, Douwe E.
Belsack, Dries
Nieboer, Koenraad H.
Willekens, Inneke
Evans, Paul
Macholl, Sven
Verfaillie, Guy
Droogmans, Steven
de Mey, Johan
Buls, Nico
author_sort Van Cauteren, Toon
collection PubMed
description OBJECTIVES: To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR) techniques on the iodine dose in coronary CTA. METHODS: Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann–Whitney U test and Chi-square analysis. RESULTS: Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11), except for streak artifacts (p = 0.02) which were considered to be more severe, although acceptable, with the 80 kVp protocol. CONCLUSIONS: Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.
format Online
Article
Text
id pubmed-5460391
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54603912017-06-15 The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography Van Cauteren, Toon Van Gompel, Gert Tanaka, Kaoru Verdries, Douwe E. Belsack, Dries Nieboer, Koenraad H. Willekens, Inneke Evans, Paul Macholl, Sven Verfaillie, Guy Droogmans, Steven de Mey, Johan Buls, Nico Biomed Res Int Research Article OBJECTIVES: To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR) techniques on the iodine dose in coronary CTA. METHODS: Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann–Whitney U test and Chi-square analysis. RESULTS: Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11), except for streak artifacts (p = 0.02) which were considered to be more severe, although acceptable, with the 80 kVp protocol. CONCLUSIONS: Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality. Hindawi 2017 2017-05-23 /pmc/articles/PMC5460391/ /pubmed/28620616 http://dx.doi.org/10.1155/2017/2476171 Text en Copyright © 2017 Toon Van Cauteren et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Van Cauteren, Toon
Van Gompel, Gert
Tanaka, Kaoru
Verdries, Douwe E.
Belsack, Dries
Nieboer, Koenraad H.
Willekens, Inneke
Evans, Paul
Macholl, Sven
Verfaillie, Guy
Droogmans, Steven
de Mey, Johan
Buls, Nico
The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
title The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
title_full The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
title_fullStr The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
title_full_unstemmed The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
title_short The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
title_sort impact of combining a low-tube voltage acquisition with iterative reconstruction on total iodine dose in coronary ct angiography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460391/
https://www.ncbi.nlm.nih.gov/pubmed/28620616
http://dx.doi.org/10.1155/2017/2476171
work_keys_str_mv AT vancauterentoon theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT vangompelgert theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT tanakakaoru theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT verdriesdouwee theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT belsackdries theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT nieboerkoenraadh theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT willekensinneke theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT evanspaul theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT machollsven theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT verfaillieguy theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT droogmanssteven theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT demeyjohan theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT bulsnico theimpactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT vancauterentoon impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT vangompelgert impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT tanakakaoru impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT verdriesdouwee impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT belsackdries impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT nieboerkoenraadh impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT willekensinneke impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT evanspaul impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT machollsven impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT verfaillieguy impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT droogmanssteven impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT demeyjohan impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography
AT bulsnico impactofcombiningalowtubevoltageacquisitionwithiterativereconstructionontotaliodinedoseincoronaryctangiography