Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut
A 20-year-old man presented with a femur fracture and epidural hemorrhage (EDH) following a fall. One month after fracture surgery, swelling developed in both legs, and he was diagnosed as having a deep-vein thrombosis and pulmonary embolism. A retrievable inferior vena cava filter (IVCF) was insert...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Thoracic and Cardiovascular Surgery
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460973/ https://www.ncbi.nlm.nih.gov/pubmed/28593162 http://dx.doi.org/10.5090/kjtcs.2017.50.3.224 |
_version_ | 1783242262302425088 |
---|---|
author | Lim, Jung Hyeon Lee, Weon Yong Ra, Yong Joon Jeong, Jae Han Park, Bong Suk Ko, Ho Hyun |
author_facet | Lim, Jung Hyeon Lee, Weon Yong Ra, Yong Joon Jeong, Jae Han Park, Bong Suk Ko, Ho Hyun |
author_sort | Lim, Jung Hyeon |
collection | PubMed |
description | A 20-year-old man presented with a femur fracture and epidural hemorrhage (EDH) following a fall. One month after fracture surgery, swelling developed in both legs, and he was diagnosed as having a deep-vein thrombosis and pulmonary embolism. A retrievable inferior vena cava filter (IVCF) was inserted, because EDH is a contraindication to anticoagulants. Four months later, he complained of abdominal pain, and a computed tomography scan showed a fractured IVCF strut. After percutaneous removal failed 3 times, the IVCF was surgically removed by orthopedists using a portable image intensifier without cardiopulmonary bypass. |
format | Online Article Text |
id | pubmed-5460973 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Society for Thoracic and Cardiovascular Surgery |
record_format | MEDLINE/PubMed |
spelling | pubmed-54609732017-06-07 Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut Lim, Jung Hyeon Lee, Weon Yong Ra, Yong Joon Jeong, Jae Han Park, Bong Suk Ko, Ho Hyun Korean J Thorac Cardiovasc Surg Case Report A 20-year-old man presented with a femur fracture and epidural hemorrhage (EDH) following a fall. One month after fracture surgery, swelling developed in both legs, and he was diagnosed as having a deep-vein thrombosis and pulmonary embolism. A retrievable inferior vena cava filter (IVCF) was inserted, because EDH is a contraindication to anticoagulants. Four months later, he complained of abdominal pain, and a computed tomography scan showed a fractured IVCF strut. After percutaneous removal failed 3 times, the IVCF was surgically removed by orthopedists using a portable image intensifier without cardiopulmonary bypass. The Korean Society for Thoracic and Cardiovascular Surgery 2017-06 2017-06-05 /pmc/articles/PMC5460973/ /pubmed/28593162 http://dx.doi.org/10.5090/kjtcs.2017.50.3.224 Text en Copyright © 2017 by The Korean Society for Thoracic and Cardiovascular Surgery. All rights Reserved. This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Lim, Jung Hyeon Lee, Weon Yong Ra, Yong Joon Jeong, Jae Han Park, Bong Suk Ko, Ho Hyun Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut |
title | Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut |
title_full | Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut |
title_fullStr | Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut |
title_full_unstemmed | Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut |
title_short | Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut |
title_sort | extravascular migration of a fractured inferior vena cava filter strut |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5460973/ https://www.ncbi.nlm.nih.gov/pubmed/28593162 http://dx.doi.org/10.5090/kjtcs.2017.50.3.224 |
work_keys_str_mv | AT limjunghyeon extravascularmigrationofafracturedinferiorvenacavafilterstrut AT leeweonyong extravascularmigrationofafracturedinferiorvenacavafilterstrut AT rayongjoon extravascularmigrationofafracturedinferiorvenacavafilterstrut AT jeongjaehan extravascularmigrationofafracturedinferiorvenacavafilterstrut AT parkbongsuk extravascularmigrationofafracturedinferiorvenacavafilterstrut AT kohohyun extravascularmigrationofafracturedinferiorvenacavafilterstrut |