Cargando…

Anterior six arms prolene mesh for high stage vaginal prolapse: five years follow-up

INTRODUCTION: In high stage vaginal prolapse, recurrence risk patients, anterior and apical defects need to be addressed in the same procedure. The pre-molded commercial mesh kits are expensive and not always available. Alternative effective and safe treatment ways, with lower costs are desirable. O...

Descripción completa

Detalles Bibliográficos
Autores principales: de Toledo, Luis Gustavo M., Costa-Matos, André, Hwang, Susane Mey, Richetti, Raquel Dória Ramos, Carramão, Silvia S., Auge, Antônio P. F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Urologia 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5462145/
https://www.ncbi.nlm.nih.gov/pubmed/28199078
http://dx.doi.org/10.1590/S1677-5538.IBJU.2016.0482
Descripción
Sumario:INTRODUCTION: In high stage vaginal prolapse, recurrence risk patients, anterior and apical defects need to be addressed in the same procedure. The pre-molded commercial mesh kits are expensive and not always available. Alternative effective and safe treatment ways, with lower costs are desirable. OBJECTIVE: To present long term follow-up of patients treated with a homemade mesh shape to correct high stage prolapses. MATERIALS AND METHODS: We describe prospectively 18 patients with anterior and apical vaginal prolapses, stages III and IV, repaired using this specific design of mesh. All patients were submitted to pre-operative clinical evaluation and urodynamics. Prolapse was classified using the pelvic organ prolapse quantification (POP-Q). Intervention Prolapse surgery, using a six arms prolene mesh, through a single anterior vaginal incision. Outcome Measurements: POP-Q, patients satisfaction, descriptive statistical analysis. RESULTS: Between February 2009 and Oct 2010, 18 consecutive women underwent the above-mentioned surgery. Mean age was 68 years. At a mean follow-up of .,4 years (5 to 5.8 years), 16 (89%) patients were continent, mean Ba point came from +4.7cm to - 2.5cm, mean C point from +2.8cm to -6.6cm and mean Bp point from +1.3 to -1.7cm. There were two (11%) objective failures, but all the patients were considered success subjectively. There were two cases of mesh vaginal extrusion. CONCLUSIONS: The homemade six arms prolene mesh allows concomitant correction of anterior and apical prolapses, through a single anterior vaginal incision, being an effective, safe and affordable treatment option when mesh is needed.