Prospective randomized comparison of a 22G core needle using standard versus capillary suction for EUS-guided sampling of solid pancreatic masses
BACKGROUND AND STUDY AIMS: The optimal technique for sampling pancreatic lesions with a 22 G Procore needle (pc) is unknown. The aims of this study were to evaluate the 22 Gpc using standard suction technique (SST) and capillary suction technique (CST) and compare diagnostic adequacy of 22 Gpc with...
Autores principales: | Weston, Brian R., Ross, William A., Bhutani, Manoop S., Lee, Jeffrey H., Pande, Mala, Sholl, Andrew B., Krishnamurthy, Savitri |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2017
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5462609/ https://www.ncbi.nlm.nih.gov/pubmed/28596983 http://dx.doi.org/10.1055/s-0043-105492 |
Ejemplares similares
-
Optimal number of needle passes during EUS-guided fine-needle biopsy of solid pancreatic lesions with 22G ProCore needles and different suction techniques: A randomized controlled trial
por: Zhou, Wei, et al.
Publicado: (2021) -
EUS and EUS-guided FNA/core biopsies in the evaluation of subepithelial lesions of the lower gastrointestinal tract: 10-year experience
por: Cazacu, Irina M., et al.
Publicado: (2020) -
EUS-guided fine-needle core liver biopsy with a modified one-pass, one-actuation wet suction technique comparing two types of EUS core needles
por: Nieto, Jose, et al.
Publicado: (2020) -
The Feasibility and Histological Diagnostic Accuracy of Novel Menghini Needle (EUS Sonopsy CY™) for Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy of Solid Pancreatic Masses: A Prospective Crossover Study Comparing Standard Biopsy Needles
por: Igarashi, Ryo, et al.
Publicado: (2019) -
EUS-through-the-needle microbiopsy forceps in pancreatic cystic lesions: A systematic review
por: Balaban, Vasile Daniel, et al.
Publicado: (2020)