Cargando…

Assessment of the interlaboratory variability and robustness of JAK2(V617F) mutation assays: A study involving a consortium of 19 Italian laboratories

To date, a plenty of techniques for the detection of JAK2(V617F) is used over different laboratories, with substantial differences in specificity and sensitivity. Therefore, to provide reliable and comparable results, the standardization of molecular techniques is mandatory. A network of 19 centers...

Descripción completa

Detalles Bibliográficos
Autores principales: Perricone, Margherita, Palandri, Francesca, Ottaviani, Emanuela, Angelini, Mario, Bagli, Laura, Bellesia, Enrica, Donati, Meris, Gemmati, Donato, Zucchini, Patrizia, Mancini, Stefania, Marchica, Valentina, Trubini, Serena, Matteis, Giovanna De, Zacomo, Silvia Di, Favarato, Mosè, Fioroni, Annamaria, Bolzonella, Caterina, Maccari, Giorgia, Navaglia, Filippo, Gatti, Daniela, Toffolatti, Luisa, Orlandi, Linda, Laloux, Vèronique, Manfrini, Marco, Galieni, Piero, Giannini, Barbara, Tieghi, Alessia, Barulli, Sara, Serino, Maria Luisa, Maccaferri, Monica, Scortechini, Anna Rita, Giuliani, Nicola, Vallisa, Daniele, Bonifacio, Massimiliano, Accorsi, Patrizia, Salbe, Cristina, Fazio, Vinicio, Gusella, Milena, Toffoletti, Eleonora, Salvucci, Marzia, Svaldi, Mirija, Gherlinzoni, Filippo, Cassavia, Francesca, Orsini, Francesco, Martinelli, Giovanni
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Impact Journals LLC 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5464813/
https://www.ncbi.nlm.nih.gov/pubmed/28427233
http://dx.doi.org/10.18632/oncotarget.15940
Descripción
Sumario:To date, a plenty of techniques for the detection of JAK2(V617F) is used over different laboratories, with substantial differences in specificity and sensitivity. Therefore, to provide reliable and comparable results, the standardization of molecular techniques is mandatory. A network of 19 centers was established to 1) evaluate the inter- and intra-laboratory variability in JAK2(V617F) quantification, 2) identify the most robust assay for the standardization of the molecular test and 3) allow consistent interpretation of individual patient analysis results. The study was conceived in 3 different rounds, in which all centers had to blindly test DNA samples with different JAK2(V617F) allele burden (AB) using both quantitative and qualitative assays. The positivity of samples with an AB < 1% was not detected by qualitative assays. Conversely, laboratories performing the quantitative approach were able to determine the expected JAK2(V617F) AB. Quantitative results were reliable across all mutation loads with moderate variability at low AB (0.1 and 1%; CV = 0.46 and 0.77, respectively). Remarkably, all laboratories clearly distinguished between the 0.1 and 1% mutated samples. In conclusion, a qualitative approach is not sensitive enough to detect the JAK2(V617F) mutation, especially at low AB. On the contrary, the ipsogen JAK2 MutaQuant CE-IVD kit resulted in a high, efficient and sensitive quantification detection of all mutation loads. This study sets the basis for the standardization of molecular techniques for JAK2(V617F) determination, which will require the employment of approved operating procedures and the use of certificated standards, such as the recent WHO 1st International Reference Panel for Genomic JAK2(V617F).