Cargando…

Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails

OBJECTIVE: To evaluate the outcomes of lengthening post-traumatic femoral segments using a recently available magnetic intramedullary (IM) lengthening system. DESIGN: Retrospective cohort study. SETTING: Urban level II Trauma Center. PATIENTS/PARTICIPANTS: Patients treated for post-traumatic femoral...

Descripción completa

Detalles Bibliográficos
Autores principales: Hammouda, Ahmed I., Jauregui, Julio J., Gesheff, Martin G., Standard, Shawn C., Conway, Janet D., Herzenberg, John E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Orthopaedic Trauma 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5466018/
https://www.ncbi.nlm.nih.gov/pubmed/28379937
http://dx.doi.org/10.1097/BOT.0000000000000828
_version_ 1783243019827281920
author Hammouda, Ahmed I.
Jauregui, Julio J.
Gesheff, Martin G.
Standard, Shawn C.
Conway, Janet D.
Herzenberg, John E.
author_facet Hammouda, Ahmed I.
Jauregui, Julio J.
Gesheff, Martin G.
Standard, Shawn C.
Conway, Janet D.
Herzenberg, John E.
author_sort Hammouda, Ahmed I.
collection PubMed
description OBJECTIVE: To evaluate the outcomes of lengthening post-traumatic femoral segments using a recently available magnetic intramedullary (IM) lengthening system. DESIGN: Retrospective cohort study. SETTING: Urban level II Trauma Center. PATIENTS/PARTICIPANTS: Patients treated for post-traumatic femoral shortening at our institution between 2012 and 2015. We identified 17 femurs lengthened (14 men and 3 women). The mean age was 30 years (range, 11–72 years). INTERVENTION: Magnetic IM lengthening system. MAIN OUTCOME MEASUREMENTS: Amount of lengthening achieved, consolidation index, and complications encountered. RESULTS: The mean follow-up was 2.2 years (range, 1–3.7 years). Sixteen patients achieved the planned lengthening, a mean of 3.8 cm (range, 2.3–6.0 cm). Regenerate consolidation occurred at a mean of 119 days (range, 57–209 days). The mean consolidation index was 32 d/cm (range, 16–51 d/cm). Three patients (18%) experienced complications. CONCLUSION: IM lengthening nails are an improvement over external fixators for treatment of post-traumatic femoral shortening. Within certain limits, their use can be extended to problems of limb-length discrepancy with angular/rotational deformity. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
format Online
Article
Text
id pubmed-5466018
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Journal of Orthopaedic Trauma
record_format MEDLINE/PubMed
spelling pubmed-54660182017-06-23 Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails Hammouda, Ahmed I. Jauregui, Julio J. Gesheff, Martin G. Standard, Shawn C. Conway, Janet D. Herzenberg, John E. J Orthop Trauma Original Article OBJECTIVE: To evaluate the outcomes of lengthening post-traumatic femoral segments using a recently available magnetic intramedullary (IM) lengthening system. DESIGN: Retrospective cohort study. SETTING: Urban level II Trauma Center. PATIENTS/PARTICIPANTS: Patients treated for post-traumatic femoral shortening at our institution between 2012 and 2015. We identified 17 femurs lengthened (14 men and 3 women). The mean age was 30 years (range, 11–72 years). INTERVENTION: Magnetic IM lengthening system. MAIN OUTCOME MEASUREMENTS: Amount of lengthening achieved, consolidation index, and complications encountered. RESULTS: The mean follow-up was 2.2 years (range, 1–3.7 years). Sixteen patients achieved the planned lengthening, a mean of 3.8 cm (range, 2.3–6.0 cm). Regenerate consolidation occurred at a mean of 119 days (range, 57–209 days). The mean consolidation index was 32 d/cm (range, 16–51 d/cm). Three patients (18%) experienced complications. CONCLUSION: IM lengthening nails are an improvement over external fixators for treatment of post-traumatic femoral shortening. Within certain limits, their use can be extended to problems of limb-length discrepancy with angular/rotational deformity. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Journal of Orthopaedic Trauma 2017-07 2017-04-20 /pmc/articles/PMC5466018/ /pubmed/28379937 http://dx.doi.org/10.1097/BOT.0000000000000828 Text en Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Original Article
Hammouda, Ahmed I.
Jauregui, Julio J.
Gesheff, Martin G.
Standard, Shawn C.
Conway, Janet D.
Herzenberg, John E.
Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails
title Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails
title_full Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails
title_fullStr Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails
title_full_unstemmed Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails
title_short Treatment of Post-Traumatic Femoral Discrepancy With PRECICE Magnetic-Powered Intramedullary Lengthening Nails
title_sort treatment of post-traumatic femoral discrepancy with precice magnetic-powered intramedullary lengthening nails
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5466018/
https://www.ncbi.nlm.nih.gov/pubmed/28379937
http://dx.doi.org/10.1097/BOT.0000000000000828
work_keys_str_mv AT hammoudaahmedi treatmentofposttraumaticfemoraldiscrepancywithprecicemagneticpoweredintramedullarylengtheningnails
AT jaureguijulioj treatmentofposttraumaticfemoraldiscrepancywithprecicemagneticpoweredintramedullarylengtheningnails
AT gesheffmarting treatmentofposttraumaticfemoraldiscrepancywithprecicemagneticpoweredintramedullarylengtheningnails
AT standardshawnc treatmentofposttraumaticfemoraldiscrepancywithprecicemagneticpoweredintramedullarylengtheningnails
AT conwayjanetd treatmentofposttraumaticfemoraldiscrepancywithprecicemagneticpoweredintramedullarylengtheningnails
AT herzenbergjohne treatmentofposttraumaticfemoraldiscrepancywithprecicemagneticpoweredintramedullarylengtheningnails