Cargando…

Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA

An analytical method is presented, combining novel microcontact imprinting technique and capacitive biosensor technology for the detection of BSA. Glass cover slips were used for preparation of protein stamps. The microcontact-BSA imprinted gold electrodes were prepared in the presence of methacryli...

Descripción completa

Detalles Bibliográficos
Autores principales: Ertürk, Gizem, Berillo, Dmitriy, Hedström, Martin, Mattiasson, Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5466099/
https://www.ncbi.nlm.nih.gov/pubmed/28626651
http://dx.doi.org/10.1016/j.btre.2014.06.006
_version_ 1783243031401463808
author Ertürk, Gizem
Berillo, Dmitriy
Hedström, Martin
Mattiasson, Bo
author_facet Ertürk, Gizem
Berillo, Dmitriy
Hedström, Martin
Mattiasson, Bo
author_sort Ertürk, Gizem
collection PubMed
description An analytical method is presented, combining novel microcontact imprinting technique and capacitive biosensor technology for the detection of BSA. Glass cover slips were used for preparation of protein stamps. The microcontact-BSA imprinted gold electrodes were prepared in the presence of methacrylic acid (MAA) and poly-ethylene glycol dimethacrylate (PEGDMA) as the cross-linker by bringing the protein stamp and the gold electrode into contact under UV-polymerization. Real-time BSA detection studies were performed in the concentration range of 1.0 × 10(−20)–1.0 × 10(−8) M with a limit of detection (LOD) of 1.0 × 10(−19) M. Cross-reactivity towards HSA and IgG were 5 and 3%, respectively. The electrodes were used for >70 assays during 2 months and retained their binding properties during all that time. The NIP (non-imprinted) electrode was used as a reference. The microcontact imprinting technology combined with the biosensor applications is a promising technology for future applications.
format Online
Article
Text
id pubmed-5466099
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54660992017-06-16 Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA Ertürk, Gizem Berillo, Dmitriy Hedström, Martin Mattiasson, Bo Biotechnol Rep (Amst) Article An analytical method is presented, combining novel microcontact imprinting technique and capacitive biosensor technology for the detection of BSA. Glass cover slips were used for preparation of protein stamps. The microcontact-BSA imprinted gold electrodes were prepared in the presence of methacrylic acid (MAA) and poly-ethylene glycol dimethacrylate (PEGDMA) as the cross-linker by bringing the protein stamp and the gold electrode into contact under UV-polymerization. Real-time BSA detection studies were performed in the concentration range of 1.0 × 10(−20)–1.0 × 10(−8) M with a limit of detection (LOD) of 1.0 × 10(−19) M. Cross-reactivity towards HSA and IgG were 5 and 3%, respectively. The electrodes were used for >70 assays during 2 months and retained their binding properties during all that time. The NIP (non-imprinted) electrode was used as a reference. The microcontact imprinting technology combined with the biosensor applications is a promising technology for future applications. Elsevier 2014-06-25 /pmc/articles/PMC5466099/ /pubmed/28626651 http://dx.doi.org/10.1016/j.btre.2014.06.006 Text en © 2014 Published by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Ertürk, Gizem
Berillo, Dmitriy
Hedström, Martin
Mattiasson, Bo
Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
title Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
title_full Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
title_fullStr Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
title_full_unstemmed Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
title_short Microcontact-BSA imprinted capacitive biosensor for real-time, sensitive and selective detection of BSA
title_sort microcontact-bsa imprinted capacitive biosensor for real-time, sensitive and selective detection of bsa
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5466099/
https://www.ncbi.nlm.nih.gov/pubmed/28626651
http://dx.doi.org/10.1016/j.btre.2014.06.006
work_keys_str_mv AT erturkgizem microcontactbsaimprintedcapacitivebiosensorforrealtimesensitiveandselectivedetectionofbsa
AT berillodmitriy microcontactbsaimprintedcapacitivebiosensorforrealtimesensitiveandselectivedetectionofbsa
AT hedstrommartin microcontactbsaimprintedcapacitivebiosensorforrealtimesensitiveandselectivedetectionofbsa
AT mattiassonbo microcontactbsaimprintedcapacitivebiosensorforrealtimesensitiveandselectivedetectionofbsa