Cargando…

“Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”

BACKGROUND: The purpose of the study was to establish the test–retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). METHODS: This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two...

Descripción completa

Detalles Bibliográficos
Autores principales: Olsen, Cecilie Fromholt, Bergland, Astrid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5466771/
https://www.ncbi.nlm.nih.gov/pubmed/28599623
http://dx.doi.org/10.1186/s12877-017-0514-4
_version_ 1783243157821980672
author Olsen, Cecilie Fromholt
Bergland, Astrid
author_facet Olsen, Cecilie Fromholt
Bergland, Astrid
author_sort Olsen, Cecilie Fromholt
collection PubMed
description BACKGROUND: The purpose of the study was to establish the test–retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). METHODS: This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. RESULTS: The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. CONCLUSIONS: The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.
format Online
Article
Text
id pubmed-5466771
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54667712017-06-14 “Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia” Olsen, Cecilie Fromholt Bergland, Astrid BMC Geriatr Research Article BACKGROUND: The purpose of the study was to establish the test–retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). METHODS: This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. RESULTS: The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. CONCLUSIONS: The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation. BioMed Central 2017-06-09 /pmc/articles/PMC5466771/ /pubmed/28599623 http://dx.doi.org/10.1186/s12877-017-0514-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Olsen, Cecilie Fromholt
Bergland, Astrid
“Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
title “Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
title_full “Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
title_fullStr “Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
title_full_unstemmed “Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
title_short “Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
title_sort “reliability of the norwegian version of the short physical performance battery in older people with and without dementia”
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5466771/
https://www.ncbi.nlm.nih.gov/pubmed/28599623
http://dx.doi.org/10.1186/s12877-017-0514-4
work_keys_str_mv AT olsenceciliefromholt reliabilityofthenorwegianversionoftheshortphysicalperformancebatteryinolderpeoplewithandwithoutdementia
AT berglandastrid reliabilityofthenorwegianversionoftheshortphysicalperformancebatteryinolderpeoplewithandwithoutdementia