Cargando…

Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)

This research consisted of a quantitative assessment, and aimed to measure the possible discrepancies between the maxillomandibular positions for centric relation (CR) and maximum intercuspation (MI), using computed tomography volumetric cone beam (cone beam method). The sample of the study consiste...

Descripción completa

Detalles Bibliográficos
Autores principales: FERREIRA, Amanda de Freitas, HENRIQUES, João César Guimarães, ALMEIDA, Guilherme Araújo, MACHADO, Asbel Rodrigues, MACHADO, Naila Aparecida de Godoi, FERNANDES, Alfredo Júlio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade De Odontologia De Bauru - USP 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5467372/
https://www.ncbi.nlm.nih.gov/pubmed/21499652
http://dx.doi.org/10.1590/S1678-77572009000700006
_version_ 1783243263075942400
author FERREIRA, Amanda de Freitas
HENRIQUES, João César Guimarães
ALMEIDA, Guilherme Araújo
MACHADO, Asbel Rodrigues
MACHADO, Naila Aparecida de Godoi
FERNANDES, Alfredo Júlio
author_facet FERREIRA, Amanda de Freitas
HENRIQUES, João César Guimarães
ALMEIDA, Guilherme Araújo
MACHADO, Asbel Rodrigues
MACHADO, Naila Aparecida de Godoi
FERNANDES, Alfredo Júlio
author_sort FERREIRA, Amanda de Freitas
collection PubMed
description This research consisted of a quantitative assessment, and aimed to measure the possible discrepancies between the maxillomandibular positions for centric relation (CR) and maximum intercuspation (MI), using computed tomography volumetric cone beam (cone beam method). The sample of the study consisted of 10 asymptomatic young adult patients divided into two types of standard occlusion: normal occlusion and Angle Class I occlusion. In order to obtain the centric relation, a JIG device and mandible manipulation were used to deprogram the habitual conditions of the jaw. The evaluations were conducted in both frontal and lateral tomographic images, showing the condyle/articular fossa relation. The images were processed in the software included in the NewTom 3G device (QR NNT software version 2.00), and 8 tomographic images were obtained per patient, four laterally and four frontally exhibiting the TMA’s (in CR and MI, on both sides, right and left). By means of tools included in another software, linear and angular measurements were performed and statistically analyzed by student t test. According to the methodology and the analysis performed in asymptomatic patients, it was not possible to detect statistically significant differences between the positions of centric relation and maximum intercuspation. However, the resources of cone beam tomography are of extreme relevance to the completion of further studies that use heterogeneous groups of samples in order to compare the results.
format Online
Article
Text
id pubmed-5467372
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Faculdade De Odontologia De Bauru - USP
record_format MEDLINE/PubMed
spelling pubmed-54673722017-06-19 Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM) FERREIRA, Amanda de Freitas HENRIQUES, João César Guimarães ALMEIDA, Guilherme Araújo MACHADO, Asbel Rodrigues MACHADO, Naila Aparecida de Godoi FERNANDES, Alfredo Júlio J Appl Oral Sci Paper Presented at the: 22nd Academic Conference of the Bauru School of Dentistry “Dr. Waldyr Antonio Janson” This research consisted of a quantitative assessment, and aimed to measure the possible discrepancies between the maxillomandibular positions for centric relation (CR) and maximum intercuspation (MI), using computed tomography volumetric cone beam (cone beam method). The sample of the study consisted of 10 asymptomatic young adult patients divided into two types of standard occlusion: normal occlusion and Angle Class I occlusion. In order to obtain the centric relation, a JIG device and mandible manipulation were used to deprogram the habitual conditions of the jaw. The evaluations were conducted in both frontal and lateral tomographic images, showing the condyle/articular fossa relation. The images were processed in the software included in the NewTom 3G device (QR NNT software version 2.00), and 8 tomographic images were obtained per patient, four laterally and four frontally exhibiting the TMA’s (in CR and MI, on both sides, right and left). By means of tools included in another software, linear and angular measurements were performed and statistically analyzed by student t test. According to the methodology and the analysis performed in asymptomatic patients, it was not possible to detect statistically significant differences between the positions of centric relation and maximum intercuspation. However, the resources of cone beam tomography are of extreme relevance to the completion of further studies that use heterogeneous groups of samples in order to compare the results. Faculdade De Odontologia De Bauru - USP 2009 /pmc/articles/PMC5467372/ /pubmed/21499652 http://dx.doi.org/10.1590/S1678-77572009000700006 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Paper Presented at the: 22nd Academic Conference of the Bauru School of Dentistry “Dr. Waldyr Antonio Janson”
FERREIRA, Amanda de Freitas
HENRIQUES, João César Guimarães
ALMEIDA, Guilherme Araújo
MACHADO, Asbel Rodrigues
MACHADO, Naila Aparecida de Godoi
FERNANDES, Alfredo Júlio
Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
title Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
title_full Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
title_fullStr Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
title_full_unstemmed Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
title_short Comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (CONE-BEAM)
title_sort comparative analysis between mandibular positions in centric relation and maximum intercuspation by cone beam computed tomography (cone-beam)
topic Paper Presented at the: 22nd Academic Conference of the Bauru School of Dentistry “Dr. Waldyr Antonio Janson”
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5467372/
https://www.ncbi.nlm.nih.gov/pubmed/21499652
http://dx.doi.org/10.1590/S1678-77572009000700006
work_keys_str_mv AT ferreiraamandadefreitas comparativeanalysisbetweenmandibularpositionsincentricrelationandmaximumintercuspationbyconebeamcomputedtomographyconebeam
AT henriquesjoaocesarguimaraes comparativeanalysisbetweenmandibularpositionsincentricrelationandmaximumintercuspationbyconebeamcomputedtomographyconebeam
AT almeidaguilhermearaujo comparativeanalysisbetweenmandibularpositionsincentricrelationandmaximumintercuspationbyconebeamcomputedtomographyconebeam
AT machadoasbelrodrigues comparativeanalysisbetweenmandibularpositionsincentricrelationandmaximumintercuspationbyconebeamcomputedtomographyconebeam
AT machadonailaaparecidadegodoi comparativeanalysisbetweenmandibularpositionsincentricrelationandmaximumintercuspationbyconebeamcomputedtomographyconebeam
AT fernandesalfredojulio comparativeanalysisbetweenmandibularpositionsincentricrelationandmaximumintercuspationbyconebeamcomputedtomographyconebeam