Cargando…

Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease

External cueing is a potentially effective strategy to reduce freezing of gait (FOG) in persons with Parkinson’s disease (PD). Case reports suggest that three-dimensional (3D) cues might be more effective in reducing FOG than two-dimensional cues. We investigate the usability of 3D augmented reality...

Descripción completa

Detalles Bibliográficos
Autores principales: Janssen, Sabine, Bolte, Benjamin, Nonnekes, Jorik, Bittner, Marian, Bloem, Bastiaan R., Heida, Tjitske, Zhao, Yan, van Wezel, Richard J. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5468397/
https://www.ncbi.nlm.nih.gov/pubmed/28659862
http://dx.doi.org/10.3389/fneur.2017.00279
_version_ 1783243431333593088
author Janssen, Sabine
Bolte, Benjamin
Nonnekes, Jorik
Bittner, Marian
Bloem, Bastiaan R.
Heida, Tjitske
Zhao, Yan
van Wezel, Richard J. A.
author_facet Janssen, Sabine
Bolte, Benjamin
Nonnekes, Jorik
Bittner, Marian
Bloem, Bastiaan R.
Heida, Tjitske
Zhao, Yan
van Wezel, Richard J. A.
author_sort Janssen, Sabine
collection PubMed
description External cueing is a potentially effective strategy to reduce freezing of gait (FOG) in persons with Parkinson’s disease (PD). Case reports suggest that three-dimensional (3D) cues might be more effective in reducing FOG than two-dimensional cues. We investigate the usability of 3D augmented reality visual cues delivered by smart glasses in comparison to conventional 3D transverse bars on the floor and auditory cueing via a metronome in reducing FOG and improving gait parameters. In laboratory experiments, 25 persons with PD and FOG performed walking tasks while wearing custom-made smart glasses under five conditions, at the end-of-dose. For two conditions, augmented visual cues (bars/staircase) were displayed via the smart glasses. The control conditions involved conventional 3D transverse bars on the floor, auditory cueing via a metronome, and no cueing. The number of FOG episodes and percentage of time spent on FOG were rated from video recordings. The stride length and its variability, cycle time and its variability, cadence, and speed were calculated from motion data collected with a motion capture suit equipped with 17 inertial measurement units. A total of 300 FOG episodes occurred in 19 out of 25 participants. There were no statistically significant differences in number of FOG episodes and percentage of time spent on FOG across the five conditions. The conventional bars increased stride length, cycle time, and stride length variability, while decreasing cadence and speed. No effects for the other conditions were found. Participants preferred the metronome most, and the augmented staircase least. They suggested to improve the comfort, esthetics, usability, field of view, and stability of the smart glasses on the head and to reduce their weight and size. In their current form, augmented visual cues delivered by smart glasses are not beneficial for persons with PD and FOG. This could be attributable to distraction, blockage of visual feedback, insufficient familiarization with the smart glasses, or display of the visual cues in the central rather than peripheral visual field. Future smart glasses are required to be more lightweight, comfortable, and user friendly to avoid distraction and blockage of sensory feedback, thus increasing usability.
format Online
Article
Text
id pubmed-5468397
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-54683972017-06-28 Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease Janssen, Sabine Bolte, Benjamin Nonnekes, Jorik Bittner, Marian Bloem, Bastiaan R. Heida, Tjitske Zhao, Yan van Wezel, Richard J. A. Front Neurol Neuroscience External cueing is a potentially effective strategy to reduce freezing of gait (FOG) in persons with Parkinson’s disease (PD). Case reports suggest that three-dimensional (3D) cues might be more effective in reducing FOG than two-dimensional cues. We investigate the usability of 3D augmented reality visual cues delivered by smart glasses in comparison to conventional 3D transverse bars on the floor and auditory cueing via a metronome in reducing FOG and improving gait parameters. In laboratory experiments, 25 persons with PD and FOG performed walking tasks while wearing custom-made smart glasses under five conditions, at the end-of-dose. For two conditions, augmented visual cues (bars/staircase) were displayed via the smart glasses. The control conditions involved conventional 3D transverse bars on the floor, auditory cueing via a metronome, and no cueing. The number of FOG episodes and percentage of time spent on FOG were rated from video recordings. The stride length and its variability, cycle time and its variability, cadence, and speed were calculated from motion data collected with a motion capture suit equipped with 17 inertial measurement units. A total of 300 FOG episodes occurred in 19 out of 25 participants. There were no statistically significant differences in number of FOG episodes and percentage of time spent on FOG across the five conditions. The conventional bars increased stride length, cycle time, and stride length variability, while decreasing cadence and speed. No effects for the other conditions were found. Participants preferred the metronome most, and the augmented staircase least. They suggested to improve the comfort, esthetics, usability, field of view, and stability of the smart glasses on the head and to reduce their weight and size. In their current form, augmented visual cues delivered by smart glasses are not beneficial for persons with PD and FOG. This could be attributable to distraction, blockage of visual feedback, insufficient familiarization with the smart glasses, or display of the visual cues in the central rather than peripheral visual field. Future smart glasses are required to be more lightweight, comfortable, and user friendly to avoid distraction and blockage of sensory feedback, thus increasing usability. Frontiers Media S.A. 2017-06-13 /pmc/articles/PMC5468397/ /pubmed/28659862 http://dx.doi.org/10.3389/fneur.2017.00279 Text en Copyright © 2017 Janssen, Bolte, Nonnekes, Bittner, Bloem, Heida, Zhao and van Wezel. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Janssen, Sabine
Bolte, Benjamin
Nonnekes, Jorik
Bittner, Marian
Bloem, Bastiaan R.
Heida, Tjitske
Zhao, Yan
van Wezel, Richard J. A.
Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease
title Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease
title_full Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease
title_fullStr Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease
title_full_unstemmed Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease
title_short Usability of Three-dimensional Augmented Visual Cues Delivered by Smart Glasses on (Freezing of) Gait in Parkinson’s Disease
title_sort usability of three-dimensional augmented visual cues delivered by smart glasses on (freezing of) gait in parkinson’s disease
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5468397/
https://www.ncbi.nlm.nih.gov/pubmed/28659862
http://dx.doi.org/10.3389/fneur.2017.00279
work_keys_str_mv AT janssensabine usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT boltebenjamin usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT nonnekesjorik usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT bittnermarian usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT bloembastiaanr usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT heidatjitske usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT zhaoyan usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease
AT vanwezelrichardja usabilityofthreedimensionalaugmentedvisualcuesdeliveredbysmartglassesonfreezingofgaitinparkinsonsdisease