Cargando…

Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk

BACKGROUND: Bile esculin azide with vancomycin (BEAV) medium is a sensitive, but slightly less specific method for vancomycin-resistant enterococci (VRE) screening. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a rapid method for identification of cli...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Tsi-Shu, Lee, Susan Shin-Jung, Lee, Chia-Chien, Chen, Chiu-Yen, Chen, Fang-Chen, Chen, Bao-Chen, Sy, Cheng Len, Wu, Kuan-Sheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469485/
https://www.ncbi.nlm.nih.gov/pubmed/28609453
http://dx.doi.org/10.1371/journal.pone.0179455
_version_ 1783243585480556544
author Huang, Tsi-Shu
Lee, Susan Shin-Jung
Lee, Chia-Chien
Chen, Chiu-Yen
Chen, Fang-Chen
Chen, Bao-Chen
Sy, Cheng Len
Wu, Kuan-Sheng
author_facet Huang, Tsi-Shu
Lee, Susan Shin-Jung
Lee, Chia-Chien
Chen, Chiu-Yen
Chen, Fang-Chen
Chen, Bao-Chen
Sy, Cheng Len
Wu, Kuan-Sheng
author_sort Huang, Tsi-Shu
collection PubMed
description BACKGROUND: Bile esculin azide with vancomycin (BEAV) medium is a sensitive, but slightly less specific method for vancomycin-resistant enterococci (VRE) screening. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a rapid method for identification of clinical pathogens. This study aimed to assess the performance of a novel combination screening test for VRE, using BEAV broth combined with MALDI-TOF MS. MATERIALS AND METHODS: Clinical specimens were collected from patients at risk of VRE carriage, and tested by the novel combination method, using selective BEAV broth culture method followed by MALDI-TOF MS identification (SBEAVM). The reference method used for comparison was the ChromID VRE agar method. RESULTS: A total of 135 specimens were collected from 78 patients, and 63 specimens tested positive for VRE positive using the ChromID VRE method (positive rate 46.7%). The sensitivity, specificity, positive predictive value, and negative predictive value of SBEAVM method after an incubation period of 28 hours were 93.7%, 90.3%, 89.4%, and 94.2%, respectively. The SBEAVM method when compared to the ChromID VRE method had a shorter turnaround time (29 vs. 48–72 hours) and lower laboratory cost ($2.11 vs. $3.23 per test). CONCLUSIONS: This study demonstrates that SBEAVM is a rapid, inexpensive, and accurate method for use in VRE screening.
format Online
Article
Text
id pubmed-5469485
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54694852017-07-03 Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk Huang, Tsi-Shu Lee, Susan Shin-Jung Lee, Chia-Chien Chen, Chiu-Yen Chen, Fang-Chen Chen, Bao-Chen Sy, Cheng Len Wu, Kuan-Sheng PLoS One Research Article BACKGROUND: Bile esculin azide with vancomycin (BEAV) medium is a sensitive, but slightly less specific method for vancomycin-resistant enterococci (VRE) screening. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a rapid method for identification of clinical pathogens. This study aimed to assess the performance of a novel combination screening test for VRE, using BEAV broth combined with MALDI-TOF MS. MATERIALS AND METHODS: Clinical specimens were collected from patients at risk of VRE carriage, and tested by the novel combination method, using selective BEAV broth culture method followed by MALDI-TOF MS identification (SBEAVM). The reference method used for comparison was the ChromID VRE agar method. RESULTS: A total of 135 specimens were collected from 78 patients, and 63 specimens tested positive for VRE positive using the ChromID VRE method (positive rate 46.7%). The sensitivity, specificity, positive predictive value, and negative predictive value of SBEAVM method after an incubation period of 28 hours were 93.7%, 90.3%, 89.4%, and 94.2%, respectively. The SBEAVM method when compared to the ChromID VRE method had a shorter turnaround time (29 vs. 48–72 hours) and lower laboratory cost ($2.11 vs. $3.23 per test). CONCLUSIONS: This study demonstrates that SBEAVM is a rapid, inexpensive, and accurate method for use in VRE screening. Public Library of Science 2017-06-13 /pmc/articles/PMC5469485/ /pubmed/28609453 http://dx.doi.org/10.1371/journal.pone.0179455 Text en © 2017 Huang et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Huang, Tsi-Shu
Lee, Susan Shin-Jung
Lee, Chia-Chien
Chen, Chiu-Yen
Chen, Fang-Chen
Chen, Bao-Chen
Sy, Cheng Len
Wu, Kuan-Sheng
Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
title Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
title_full Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
title_fullStr Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
title_full_unstemmed Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
title_short Evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
title_sort evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry assisted, selective broth method to screen for vancomycin-resistant enterococci in patients at high risk
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469485/
https://www.ncbi.nlm.nih.gov/pubmed/28609453
http://dx.doi.org/10.1371/journal.pone.0179455
work_keys_str_mv AT huangtsishu evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT leesusanshinjung evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT leechiachien evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT chenchiuyen evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT chenfangchen evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT chenbaochen evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT sychenglen evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk
AT wukuansheng evaluationofamatrixassistedlaserdesorptionionizationtimeofflightmassspectrometryassistedselectivebrothmethodtoscreenforvancomycinresistantenterococciinpatientsathighrisk