Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period
Catheter-related infections in peritoneal dialysis (PD) remain a significant complication, and some patients with recurrent exit-site (ESI) and/or tunnel infections may experience external cuff extrusion. In these cases, cuff-shaving has been described as a possible course of treatment. During a 4-y...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469562/ https://www.ncbi.nlm.nih.gov/pubmed/28638613 http://dx.doi.org/10.1093/ckj/sfw089 |
_version_ | 1783243601218633728 |
---|---|
author | Debowski, Jedrzej A. Wærp, Cora Kjellevold, Stig A. Abedini, Sadollah |
author_facet | Debowski, Jedrzej A. Wærp, Cora Kjellevold, Stig A. Abedini, Sadollah |
author_sort | Debowski, Jedrzej A. |
collection | PubMed |
description | Catheter-related infections in peritoneal dialysis (PD) remain a significant complication, and some patients with recurrent exit-site (ESI) and/or tunnel infections may experience external cuff extrusion. In these cases, cuff-shaving has been described as a possible course of treatment. During a 4-year period, there were 44 patients with PD at our department; all received double-cuffed Tenckhoff catheters. Six (13%) never started on PD. Five (13%) of the 38 active PD patients experienced cuff extrusion. Causes of end-stage renal disease (ESRD) were diabetic nephropathy (n = 1), toxic nephropathy (n = 1), hypertensive nephrosclerosis (n = 1), systemic disease (n = 1) and one with unknown cause. PD catheters were inserted by the Department of Surgery and our patients waited a mean of 3.71 weeks (0.57–7.86) from catheter insertion to PD start. Patients were followed up by monthly and even fortnightly during infections. Our cohort experienced two (1–5) ESIs per patient prior to cuff extrusion. Cultures showed growth of Staphylococcus aureus and the patients received dicloxacillin orally 500 mg qid for 3–4 weeks. Of the 38 active PD patients, 5 (13%) developed cuff extrusion with an incidence of 0.20 episodes/patient/year, manifesting on average at 32 weeks (17.3–40.6), due to repeated ESI in four patients and substantial weight loss in one patient. All five underwent cuff-shaving and the ESIs resolved completely in 80% of the cases assisted by supplemental treatment with mupirocin and/or dicloxacillin. There were no complications to the cuff-shaving procedure itself. None of the five patients experienced new ESIs after cuff-shaving had been performed. Cuff-shaving reduces the rate of recurring ESIs. The procedure is safe, if performed correctly, and poses no risk to the patient or the catheter. |
format | Online Article Text |
id | pubmed-5469562 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-54695622017-06-21 Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period Debowski, Jedrzej A. Wærp, Cora Kjellevold, Stig A. Abedini, Sadollah Clin Kidney J Peritoneal Dialysis Catheter-related infections in peritoneal dialysis (PD) remain a significant complication, and some patients with recurrent exit-site (ESI) and/or tunnel infections may experience external cuff extrusion. In these cases, cuff-shaving has been described as a possible course of treatment. During a 4-year period, there were 44 patients with PD at our department; all received double-cuffed Tenckhoff catheters. Six (13%) never started on PD. Five (13%) of the 38 active PD patients experienced cuff extrusion. Causes of end-stage renal disease (ESRD) were diabetic nephropathy (n = 1), toxic nephropathy (n = 1), hypertensive nephrosclerosis (n = 1), systemic disease (n = 1) and one with unknown cause. PD catheters were inserted by the Department of Surgery and our patients waited a mean of 3.71 weeks (0.57–7.86) from catheter insertion to PD start. Patients were followed up by monthly and even fortnightly during infections. Our cohort experienced two (1–5) ESIs per patient prior to cuff extrusion. Cultures showed growth of Staphylococcus aureus and the patients received dicloxacillin orally 500 mg qid for 3–4 weeks. Of the 38 active PD patients, 5 (13%) developed cuff extrusion with an incidence of 0.20 episodes/patient/year, manifesting on average at 32 weeks (17.3–40.6), due to repeated ESI in four patients and substantial weight loss in one patient. All five underwent cuff-shaving and the ESIs resolved completely in 80% of the cases assisted by supplemental treatment with mupirocin and/or dicloxacillin. There were no complications to the cuff-shaving procedure itself. None of the five patients experienced new ESIs after cuff-shaving had been performed. Cuff-shaving reduces the rate of recurring ESIs. The procedure is safe, if performed correctly, and poses no risk to the patient or the catheter. Oxford University Press 2017-02 2016-09-16 /pmc/articles/PMC5469562/ /pubmed/28638613 http://dx.doi.org/10.1093/ckj/sfw089 Text en © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Peritoneal Dialysis Debowski, Jedrzej A. Wærp, Cora Kjellevold, Stig A. Abedini, Sadollah Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
title | Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
title_full | Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
title_fullStr | Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
title_full_unstemmed | Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
title_short | Cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
title_sort | cuff extrusion in peritoneal dialysis: single-centre experience with the cuff-shaving procedure in five patients over a 4-year period |
topic | Peritoneal Dialysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469562/ https://www.ncbi.nlm.nih.gov/pubmed/28638613 http://dx.doi.org/10.1093/ckj/sfw089 |
work_keys_str_mv | AT debowskijedrzeja cuffextrusioninperitonealdialysissinglecentreexperiencewiththecuffshavingprocedureinfivepatientsovera4yearperiod AT wærpcora cuffextrusioninperitonealdialysissinglecentreexperiencewiththecuffshavingprocedureinfivepatientsovera4yearperiod AT kjellevoldstiga cuffextrusioninperitonealdialysissinglecentreexperiencewiththecuffshavingprocedureinfivepatientsovera4yearperiod AT abedinisadollah cuffextrusioninperitonealdialysissinglecentreexperiencewiththecuffshavingprocedureinfivepatientsovera4yearperiod |