Cargando…

Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS

PURPOSE: Glutathione (GSH) is an important intracellular antioxidant in the brain. A number of studies report its measurement by localized (1)H spectroscopy using PRESS and STEAM. This study evaluates the reliability and accuracy of GSH measurements from PRESS at 3 Tesla (T) and compares the results...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanaei Nezhad, Faezeh, Anton, Adriana, Parkes, Laura M., Deakin, Bill, Williams, Stephen R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469715/
https://www.ncbi.nlm.nih.gov/pubmed/27797108
http://dx.doi.org/10.1002/mrm.26532
_version_ 1783243625874849792
author Sanaei Nezhad, Faezeh
Anton, Adriana
Parkes, Laura M.
Deakin, Bill
Williams, Stephen R.
author_facet Sanaei Nezhad, Faezeh
Anton, Adriana
Parkes, Laura M.
Deakin, Bill
Williams, Stephen R.
author_sort Sanaei Nezhad, Faezeh
collection PubMed
description PURPOSE: Glutathione (GSH) is an important intracellular antioxidant in the brain. A number of studies report its measurement by localized (1)H spectroscopy using PRESS and STEAM. This study evaluates the reliability and accuracy of GSH measurements from PRESS at 3 Tesla (T) and compares the results to those obtained with MEGA‐PRESS. METHODS: Phantoms containing brain metabolites, identical except for variable GSH concentration between 0 and 24 mM, were scanned using PRESS (echo time (TE) = 35 ms) and MEGA‐PRESS (optimized TE = 130 ms) at 3 T. Spectra of the anterior cingulate cortex and occipital cortex in seven healthy volunteers were also acquired. RESULTS: Phantom GSH concentrations from 0 to 3mM were unreliably quantified using PRESS, although at 4 mM and above there was a linear relationship between measured and true concentrations (R(2) = 0.99). Using MEGA‐PRESS, there was no signal detected at 0 mM GSH, plus a linear relationship (R(2) = 0.99) over the full range from 0–24 mM. In brain, concentrations calculated from MEGA‐PRESS and PRESS were significantly different in occipital cortex (P < 0.001). Moreover, only MEGA‐PRESS reported significant differences in GSH between the two brain regions (P = 0.003). CONCLUSION: Due to uncertainties in GSH quantification raised by the study, the authors conclude that physiological concentrations (<4 mM) of GSH cannot be reliably quantified from PRESS (TE = 35 ms) spectra at 3 T. Magn Reson Med 78:1257–1266, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
format Online
Article
Text
id pubmed-5469715
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-54697152017-10-25 Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS Sanaei Nezhad, Faezeh Anton, Adriana Parkes, Laura M. Deakin, Bill Williams, Stephen R. Magn Reson Med Full Papers—Spectroscopic Methodology PURPOSE: Glutathione (GSH) is an important intracellular antioxidant in the brain. A number of studies report its measurement by localized (1)H spectroscopy using PRESS and STEAM. This study evaluates the reliability and accuracy of GSH measurements from PRESS at 3 Tesla (T) and compares the results to those obtained with MEGA‐PRESS. METHODS: Phantoms containing brain metabolites, identical except for variable GSH concentration between 0 and 24 mM, were scanned using PRESS (echo time (TE) = 35 ms) and MEGA‐PRESS (optimized TE = 130 ms) at 3 T. Spectra of the anterior cingulate cortex and occipital cortex in seven healthy volunteers were also acquired. RESULTS: Phantom GSH concentrations from 0 to 3mM were unreliably quantified using PRESS, although at 4 mM and above there was a linear relationship between measured and true concentrations (R(2) = 0.99). Using MEGA‐PRESS, there was no signal detected at 0 mM GSH, plus a linear relationship (R(2) = 0.99) over the full range from 0–24 mM. In brain, concentrations calculated from MEGA‐PRESS and PRESS were significantly different in occipital cortex (P < 0.001). Moreover, only MEGA‐PRESS reported significant differences in GSH between the two brain regions (P = 0.003). CONCLUSION: Due to uncertainties in GSH quantification raised by the study, the authors conclude that physiological concentrations (<4 mM) of GSH cannot be reliably quantified from PRESS (TE = 35 ms) spectra at 3 T. Magn Reson Med 78:1257–1266, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2016-10-31 2017-10 /pmc/articles/PMC5469715/ /pubmed/27797108 http://dx.doi.org/10.1002/mrm.26532 Text en © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Spectroscopic Methodology
Sanaei Nezhad, Faezeh
Anton, Adriana
Parkes, Laura M.
Deakin, Bill
Williams, Stephen R.
Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
title Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
title_full Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
title_fullStr Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
title_full_unstemmed Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
title_short Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
title_sort quantification of glutathione in the human brain by mr spectroscopy at 3 tesla: comparison of press and mega‐press
topic Full Papers—Spectroscopic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469715/
https://www.ncbi.nlm.nih.gov/pubmed/27797108
http://dx.doi.org/10.1002/mrm.26532
work_keys_str_mv AT sanaeinezhadfaezeh quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress
AT antonadriana quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress
AT parkeslauram quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress
AT deakinbill quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress
AT williamsstephenr quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress