Cargando…
Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
PURPOSE: Glutathione (GSH) is an important intracellular antioxidant in the brain. A number of studies report its measurement by localized (1)H spectroscopy using PRESS and STEAM. This study evaluates the reliability and accuracy of GSH measurements from PRESS at 3 Tesla (T) and compares the results...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469715/ https://www.ncbi.nlm.nih.gov/pubmed/27797108 http://dx.doi.org/10.1002/mrm.26532 |
_version_ | 1783243625874849792 |
---|---|
author | Sanaei Nezhad, Faezeh Anton, Adriana Parkes, Laura M. Deakin, Bill Williams, Stephen R. |
author_facet | Sanaei Nezhad, Faezeh Anton, Adriana Parkes, Laura M. Deakin, Bill Williams, Stephen R. |
author_sort | Sanaei Nezhad, Faezeh |
collection | PubMed |
description | PURPOSE: Glutathione (GSH) is an important intracellular antioxidant in the brain. A number of studies report its measurement by localized (1)H spectroscopy using PRESS and STEAM. This study evaluates the reliability and accuracy of GSH measurements from PRESS at 3 Tesla (T) and compares the results to those obtained with MEGA‐PRESS. METHODS: Phantoms containing brain metabolites, identical except for variable GSH concentration between 0 and 24 mM, were scanned using PRESS (echo time (TE) = 35 ms) and MEGA‐PRESS (optimized TE = 130 ms) at 3 T. Spectra of the anterior cingulate cortex and occipital cortex in seven healthy volunteers were also acquired. RESULTS: Phantom GSH concentrations from 0 to 3mM were unreliably quantified using PRESS, although at 4 mM and above there was a linear relationship between measured and true concentrations (R(2) = 0.99). Using MEGA‐PRESS, there was no signal detected at 0 mM GSH, plus a linear relationship (R(2) = 0.99) over the full range from 0–24 mM. In brain, concentrations calculated from MEGA‐PRESS and PRESS were significantly different in occipital cortex (P < 0.001). Moreover, only MEGA‐PRESS reported significant differences in GSH between the two brain regions (P = 0.003). CONCLUSION: Due to uncertainties in GSH quantification raised by the study, the authors conclude that physiological concentrations (<4 mM) of GSH cannot be reliably quantified from PRESS (TE = 35 ms) spectra at 3 T. Magn Reson Med 78:1257–1266, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
format | Online Article Text |
id | pubmed-5469715 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-54697152017-10-25 Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS Sanaei Nezhad, Faezeh Anton, Adriana Parkes, Laura M. Deakin, Bill Williams, Stephen R. Magn Reson Med Full Papers—Spectroscopic Methodology PURPOSE: Glutathione (GSH) is an important intracellular antioxidant in the brain. A number of studies report its measurement by localized (1)H spectroscopy using PRESS and STEAM. This study evaluates the reliability and accuracy of GSH measurements from PRESS at 3 Tesla (T) and compares the results to those obtained with MEGA‐PRESS. METHODS: Phantoms containing brain metabolites, identical except for variable GSH concentration between 0 and 24 mM, were scanned using PRESS (echo time (TE) = 35 ms) and MEGA‐PRESS (optimized TE = 130 ms) at 3 T. Spectra of the anterior cingulate cortex and occipital cortex in seven healthy volunteers were also acquired. RESULTS: Phantom GSH concentrations from 0 to 3mM were unreliably quantified using PRESS, although at 4 mM and above there was a linear relationship between measured and true concentrations (R(2) = 0.99). Using MEGA‐PRESS, there was no signal detected at 0 mM GSH, plus a linear relationship (R(2) = 0.99) over the full range from 0–24 mM. In brain, concentrations calculated from MEGA‐PRESS and PRESS were significantly different in occipital cortex (P < 0.001). Moreover, only MEGA‐PRESS reported significant differences in GSH between the two brain regions (P = 0.003). CONCLUSION: Due to uncertainties in GSH quantification raised by the study, the authors conclude that physiological concentrations (<4 mM) of GSH cannot be reliably quantified from PRESS (TE = 35 ms) spectra at 3 T. Magn Reson Med 78:1257–1266, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2016-10-31 2017-10 /pmc/articles/PMC5469715/ /pubmed/27797108 http://dx.doi.org/10.1002/mrm.26532 Text en © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Full Papers—Spectroscopic Methodology Sanaei Nezhad, Faezeh Anton, Adriana Parkes, Laura M. Deakin, Bill Williams, Stephen R. Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS |
title | Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
|
title_full | Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
|
title_fullStr | Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
|
title_full_unstemmed | Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
|
title_short | Quantification of glutathione in the human brain by MR spectroscopy at 3 Tesla: Comparison of PRESS and MEGA‐PRESS
|
title_sort | quantification of glutathione in the human brain by mr spectroscopy at 3 tesla: comparison of press and mega‐press |
topic | Full Papers—Spectroscopic Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5469715/ https://www.ncbi.nlm.nih.gov/pubmed/27797108 http://dx.doi.org/10.1002/mrm.26532 |
work_keys_str_mv | AT sanaeinezhadfaezeh quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress AT antonadriana quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress AT parkeslauram quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress AT deakinbill quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress AT williamsstephenr quantificationofglutathioneinthehumanbrainbymrspectroscopyat3teslacomparisonofpressandmegapress |