Cargando…

Serum levels of bupivacaine after pre-peritoneal bolus vs. epidural bolus injection for analgesia in abdominal surgery: A safety study within a randomized controlled trial

BACKGROUND: Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of...

Descripción completa

Detalles Bibliográficos
Autores principales: Mungroop, Timothy H., van Samkar, Ganapathy, Geerts, Bart F., van Dieren, Susan, Besselink, Marc G., Veelo, Denise P., Lirk, Philipp
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5470670/
https://www.ncbi.nlm.nih.gov/pubmed/28614364
http://dx.doi.org/10.1371/journal.pone.0178917
Descripción
Sumario:BACKGROUND: Continuous wound infiltration (CWI) has become increasingly popular in recent years as an alternative to epidural analgesia. As catheters are not placed until the end of surgery, more intraoperative opioid analgesics might be needed. We, therefore, added a single pre-peritoneal bolus of bupivacaine at the start of laparotomy, similar to the bolus given with epidural analgesia. METHODS: This was a comparative study within a randomized controlled trial (NTR4948). Patients undergoing hepato-pancreato-biliary surgery received either a pre-peritoneal bolus of 30ml bupivacaine 0.25%, or an epidural bolus of 10ml bupivacaine 0.25% at the start of laparotomy. In a subgroup of patients, we sampled blood and determined bupivacaine serum levels 20, 40, 60 and 80 minutes after bolus injection. We assumed toxicity of bupivacaine to be >1000 ng/ml. RESULTS: A total of 20 patients participated in this sub-study. All plasma levels measured as well as the upper limit of the predicted 99% confidence intervals per time point were well below the toxicity limit. In a mixed linear-effect model both groups did not differ statistically significant (p = 0.131). The intra-operative use of opioids was higher with CWI as compared to epidural (86 (SD 73) μg sufentanil vs. 50 (SD 32). CONCLUSIONS: In this exploratory study, the pre-peritoneal bolus using bupivacaine resulted in serum bupivacaine concentrations well below the commonly accepted toxic threshold. With CWI more additional analgesics are needed intraoperatively as compared to epidural analgesia, although this is compensated by a reduction in use of vasopressors with CWI. TRIAL REGISTRATION: Netherlands Trial Register NTR4948