Cargando…
Photosensor-Based Latency Measurement System for Head-Mounted Displays
In this paper, a photosensor-based latency measurement system for head-mounted displays (HMDs) is proposed. The motion-to-photon latency is the greatest reason for motion sickness and dizziness felt by users when wearing an HMD system. Therefore, a measurement system is required to accurately measur...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5470788/ https://www.ncbi.nlm.nih.gov/pubmed/28505115 http://dx.doi.org/10.3390/s17051112 |
_version_ | 1783243822797422592 |
---|---|
author | Seo, Min-Woo Choi, Song-Woo Lee, Sang-Lyn Oh, Eui-Yeol Baek, Jong-Sang Kang, Suk-Ju |
author_facet | Seo, Min-Woo Choi, Song-Woo Lee, Sang-Lyn Oh, Eui-Yeol Baek, Jong-Sang Kang, Suk-Ju |
author_sort | Seo, Min-Woo |
collection | PubMed |
description | In this paper, a photosensor-based latency measurement system for head-mounted displays (HMDs) is proposed. The motion-to-photon latency is the greatest reason for motion sickness and dizziness felt by users when wearing an HMD system. Therefore, a measurement system is required to accurately measure and analyze the latency to reduce these problems. The existing measurement system does not consider the actual physical movement in humans, and its accuracy is also very low. However, the proposed system considers the physical head movement and is highly accurate. Specifically, it consists of a head position model-based rotary platform, pixel luminance change detector, and signal analysis and calculation modules. Using these modules, the proposed system can exactly measure the latency, which is the time difference between the physical movement for a user and the luminance change of an output image. In the experiment using a commercial HMD, the latency was measured to be up to 47.05 ms. In addition, the measured latency increased up to 381.17 ms when increasing the rendering workload in the HMD. |
format | Online Article Text |
id | pubmed-5470788 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-54707882017-06-16 Photosensor-Based Latency Measurement System for Head-Mounted Displays Seo, Min-Woo Choi, Song-Woo Lee, Sang-Lyn Oh, Eui-Yeol Baek, Jong-Sang Kang, Suk-Ju Sensors (Basel) Article In this paper, a photosensor-based latency measurement system for head-mounted displays (HMDs) is proposed. The motion-to-photon latency is the greatest reason for motion sickness and dizziness felt by users when wearing an HMD system. Therefore, a measurement system is required to accurately measure and analyze the latency to reduce these problems. The existing measurement system does not consider the actual physical movement in humans, and its accuracy is also very low. However, the proposed system considers the physical head movement and is highly accurate. Specifically, it consists of a head position model-based rotary platform, pixel luminance change detector, and signal analysis and calculation modules. Using these modules, the proposed system can exactly measure the latency, which is the time difference between the physical movement for a user and the luminance change of an output image. In the experiment using a commercial HMD, the latency was measured to be up to 47.05 ms. In addition, the measured latency increased up to 381.17 ms when increasing the rendering workload in the HMD. MDPI 2017-05-15 /pmc/articles/PMC5470788/ /pubmed/28505115 http://dx.doi.org/10.3390/s17051112 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Seo, Min-Woo Choi, Song-Woo Lee, Sang-Lyn Oh, Eui-Yeol Baek, Jong-Sang Kang, Suk-Ju Photosensor-Based Latency Measurement System for Head-Mounted Displays |
title | Photosensor-Based Latency Measurement System for Head-Mounted Displays |
title_full | Photosensor-Based Latency Measurement System for Head-Mounted Displays |
title_fullStr | Photosensor-Based Latency Measurement System for Head-Mounted Displays |
title_full_unstemmed | Photosensor-Based Latency Measurement System for Head-Mounted Displays |
title_short | Photosensor-Based Latency Measurement System for Head-Mounted Displays |
title_sort | photosensor-based latency measurement system for head-mounted displays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5470788/ https://www.ncbi.nlm.nih.gov/pubmed/28505115 http://dx.doi.org/10.3390/s17051112 |
work_keys_str_mv | AT seominwoo photosensorbasedlatencymeasurementsystemforheadmounteddisplays AT choisongwoo photosensorbasedlatencymeasurementsystemforheadmounteddisplays AT leesanglyn photosensorbasedlatencymeasurementsystemforheadmounteddisplays AT oheuiyeol photosensorbasedlatencymeasurementsystemforheadmounteddisplays AT baekjongsang photosensorbasedlatencymeasurementsystemforheadmounteddisplays AT kangsukju photosensorbasedlatencymeasurementsystemforheadmounteddisplays |