The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease

INTRODUCTION: Deep brain stimulation (DBS) is a well-established therapy for the treatment of advanced Parkinson’s disease (PD) in patients experiencing motor fluctuations and medication-refractory tremor. Despite the relative tolerability and safety of this procedure, associated complications and u...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jing, Wang, Tao, Zhang, Chen-cheng, Zeljic, Kristina, Zhan, Shikun, Sun, Bo-min, Li, Dian-you
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5472429/
https://www.ncbi.nlm.nih.gov/pubmed/28652714
http://dx.doi.org/10.2147/CIA.S130882
_version_ 1783244120012095488
author Zhang, Jing
Wang, Tao
Zhang, Chen-cheng
Zeljic, Kristina
Zhan, Shikun
Sun, Bo-min
Li, Dian-you
author_facet Zhang, Jing
Wang, Tao
Zhang, Chen-cheng
Zeljic, Kristina
Zhan, Shikun
Sun, Bo-min
Li, Dian-you
author_sort Zhang, Jing
collection PubMed
description INTRODUCTION: Deep brain stimulation (DBS) is a well-established therapy for the treatment of advanced Parkinson’s disease (PD) in patients experiencing motor fluctuations and medication-refractory tremor. Despite the relative tolerability and safety of this procedure, associated complications and unnatural deaths are still unavoidable. METHODS: In this study, hardware-related complications and the causes of unnatural death were retrospectively analyzed in 478 patients with PD who were treated with DBS. RESULTS: The results showed a 3-year survival rate of 98.6% and a 5-year survival rate of 96.4% for patients with PD who underwent DBS treatment at the study center. Pneumonia was the cause of death with the highest frequency. Prophylactic antibiotics and steroids or antihistamine drugs were adopted to reduce the risk of infection. Twenty-two patients (4.6%) experienced hardware-related complications. CONCLUSION: Deaths of PD patients who receive DBS are typically unrelated to the disease itself or complications associated with the surgery. Pneumonia, malignant tumors, asphyxia, and multiple-organ failure are the common causes of death. Swallowing-related problems may be the most important clinical symptom in late-stage PD, as they cannot be stabilized or improved by DBS alone, and are potentially lethal. Although prophylactic antibiotics and steroids or antihistamine drugs may reduce the risk of infection, it is imperative to identify high-risk patients for whom a therapeutic approach not requiring an implantable device is more suitable, for example, pallidotomy and potentially transcranial ultrasound.
format Online
Article
Text
id pubmed-5472429
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-54724292017-06-26 The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease Zhang, Jing Wang, Tao Zhang, Chen-cheng Zeljic, Kristina Zhan, Shikun Sun, Bo-min Li, Dian-you Clin Interv Aging Original Research INTRODUCTION: Deep brain stimulation (DBS) is a well-established therapy for the treatment of advanced Parkinson’s disease (PD) in patients experiencing motor fluctuations and medication-refractory tremor. Despite the relative tolerability and safety of this procedure, associated complications and unnatural deaths are still unavoidable. METHODS: In this study, hardware-related complications and the causes of unnatural death were retrospectively analyzed in 478 patients with PD who were treated with DBS. RESULTS: The results showed a 3-year survival rate of 98.6% and a 5-year survival rate of 96.4% for patients with PD who underwent DBS treatment at the study center. Pneumonia was the cause of death with the highest frequency. Prophylactic antibiotics and steroids or antihistamine drugs were adopted to reduce the risk of infection. Twenty-two patients (4.6%) experienced hardware-related complications. CONCLUSION: Deaths of PD patients who receive DBS are typically unrelated to the disease itself or complications associated with the surgery. Pneumonia, malignant tumors, asphyxia, and multiple-organ failure are the common causes of death. Swallowing-related problems may be the most important clinical symptom in late-stage PD, as they cannot be stabilized or improved by DBS alone, and are potentially lethal. Although prophylactic antibiotics and steroids or antihistamine drugs may reduce the risk of infection, it is imperative to identify high-risk patients for whom a therapeutic approach not requiring an implantable device is more suitable, for example, pallidotomy and potentially transcranial ultrasound. Dove Medical Press 2017-06-08 /pmc/articles/PMC5472429/ /pubmed/28652714 http://dx.doi.org/10.2147/CIA.S130882 Text en © 2017 Zhang et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Zhang, Jing
Wang, Tao
Zhang, Chen-cheng
Zeljic, Kristina
Zhan, Shikun
Sun, Bo-min
Li, Dian-you
The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease
title The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease
title_full The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease
title_fullStr The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease
title_full_unstemmed The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease
title_short The safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with Parkinson’s disease
title_sort safety issues and hardware-related complications of deep brain stimulation therapy: a single-center retrospective analysis of 478 patients with parkinson’s disease
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5472429/
https://www.ncbi.nlm.nih.gov/pubmed/28652714
http://dx.doi.org/10.2147/CIA.S130882
work_keys_str_mv AT zhangjing thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT wangtao thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zhangchencheng thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zeljickristina thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zhanshikun thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT sunbomin thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT lidianyou thesafetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zhangjing safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT wangtao safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zhangchencheng safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zeljickristina safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT zhanshikun safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT sunbomin safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease
AT lidianyou safetyissuesandhardwarerelatedcomplicationsofdeepbrainstimulationtherapyasinglecenterretrospectiveanalysisof478patientswithparkinsonsdisease