Cargando…

Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study

BACKGROUND: Eustachian tube (ET) dysfunction can be very difficult to diagnose accurately. Our aim is to determine whether a newly developed sonotubometric test using clicks can reliably detect ET opening during swallowing in normal ET subjects, and patulous ET (PET) in subjects with ET dysfunction....

Descripción completa

Detalles Bibliográficos
Autores principales: Pyne, Justin M., Amoako-Tuffour, Yaw, Earle, Guy, McIntyre, Graham, Butler, Michael B., Bance, Manohar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5472917/
https://www.ncbi.nlm.nih.gov/pubmed/28619119
http://dx.doi.org/10.1186/s40463-017-0227-x
_version_ 1783244206109622272
author Pyne, Justin M.
Amoako-Tuffour, Yaw
Earle, Guy
McIntyre, Graham
Butler, Michael B.
Bance, Manohar
author_facet Pyne, Justin M.
Amoako-Tuffour, Yaw
Earle, Guy
McIntyre, Graham
Butler, Michael B.
Bance, Manohar
author_sort Pyne, Justin M.
collection PubMed
description BACKGROUND: Eustachian tube (ET) dysfunction can be very difficult to diagnose accurately. Our aim is to determine whether a newly developed sonotubometric test using clicks can reliably detect ET opening during swallowing in normal ET subjects, and patulous ET (PET) in subjects with ET dysfunction. METHODS: Sixteen subjects (19 normal ET ears and 6 PET ears) were individually placed in a sound-isolated audiometry booth and subjected to a 1000Hz click train stimulus, played through the nose. PET subjects were identified through the ET clinic at our institution, while healthy subjects were recruited. Transmission through the ET was recorded by a microphone in the ear ipsilateral to the presenting nostril, during no swallow and swallow states, and this was used to compute a power ratio (power in the frequency range of interest to the whole frequency range). The power transmission ratio both before and after the swallow was averaged, and represented the baseline (BaseR). The power transmission ratio during swallow represented the peak (PeakR). The same process was repeated in the absence of a stimulus to account for swallowing noise. Wilcoxon rank rum tests were performed to determine statistical significance. RESULTS: It was found that for healthy ET patients, the median difference between the PeakR and BaseR was 0.51 (p = 0.004). For the PET patients in this study, the median difference between the PeakR and the BaseR was 3.30 (p = 0.041). Comparing the baseline between groups revealed that PET patients had a median BaseR 1.05 higher than healthy ET patients. PET patients had a median PeakR of 3.84 higher than healthy ET patients. Both were deemed to be statistically significant (p = 0.003, p = 0.003 respectively). A significant difference was found between median PeakR for the stimulus and no-stimulus condition for the healthy ET group (0.59, p < 0.001) and for the PET group (4.39, p = 0.031), indicating that it was unlikely that swallowing noise caused false positive results. CONCLUSION: The results of this study suggest that a novel click stimulus is capable of detecting ET opening during swallowing in healthy patients as well as highlighting PET in diseased subjects.
format Online
Article
Text
id pubmed-5472917
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54729172017-06-21 Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study Pyne, Justin M. Amoako-Tuffour, Yaw Earle, Guy McIntyre, Graham Butler, Michael B. Bance, Manohar J Otolaryngol Head Neck Surg Original Research Article BACKGROUND: Eustachian tube (ET) dysfunction can be very difficult to diagnose accurately. Our aim is to determine whether a newly developed sonotubometric test using clicks can reliably detect ET opening during swallowing in normal ET subjects, and patulous ET (PET) in subjects with ET dysfunction. METHODS: Sixteen subjects (19 normal ET ears and 6 PET ears) were individually placed in a sound-isolated audiometry booth and subjected to a 1000Hz click train stimulus, played through the nose. PET subjects were identified through the ET clinic at our institution, while healthy subjects were recruited. Transmission through the ET was recorded by a microphone in the ear ipsilateral to the presenting nostril, during no swallow and swallow states, and this was used to compute a power ratio (power in the frequency range of interest to the whole frequency range). The power transmission ratio both before and after the swallow was averaged, and represented the baseline (BaseR). The power transmission ratio during swallow represented the peak (PeakR). The same process was repeated in the absence of a stimulus to account for swallowing noise. Wilcoxon rank rum tests were performed to determine statistical significance. RESULTS: It was found that for healthy ET patients, the median difference between the PeakR and BaseR was 0.51 (p = 0.004). For the PET patients in this study, the median difference between the PeakR and the BaseR was 3.30 (p = 0.041). Comparing the baseline between groups revealed that PET patients had a median BaseR 1.05 higher than healthy ET patients. PET patients had a median PeakR of 3.84 higher than healthy ET patients. Both were deemed to be statistically significant (p = 0.003, p = 0.003 respectively). A significant difference was found between median PeakR for the stimulus and no-stimulus condition for the healthy ET group (0.59, p < 0.001) and for the PET group (4.39, p = 0.031), indicating that it was unlikely that swallowing noise caused false positive results. CONCLUSION: The results of this study suggest that a novel click stimulus is capable of detecting ET opening during swallowing in healthy patients as well as highlighting PET in diseased subjects. BioMed Central 2017-06-15 /pmc/articles/PMC5472917/ /pubmed/28619119 http://dx.doi.org/10.1186/s40463-017-0227-x Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Original Research Article
Pyne, Justin M.
Amoako-Tuffour, Yaw
Earle, Guy
McIntyre, Graham
Butler, Michael B.
Bance, Manohar
Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
title Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
title_full Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
title_fullStr Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
title_full_unstemmed Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
title_short Transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
title_sort transmission of a novel sonotubometry acoustic click stimulus in healthy and patulous eustachian tube subjects: a retrospective case -control study
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5472917/
https://www.ncbi.nlm.nih.gov/pubmed/28619119
http://dx.doi.org/10.1186/s40463-017-0227-x
work_keys_str_mv AT pynejustinm transmissionofanovelsonotubometryacousticclickstimulusinhealthyandpatulouseustachiantubesubjectsaretrospectivecasecontrolstudy
AT amoakotuffouryaw transmissionofanovelsonotubometryacousticclickstimulusinhealthyandpatulouseustachiantubesubjectsaretrospectivecasecontrolstudy
AT earleguy transmissionofanovelsonotubometryacousticclickstimulusinhealthyandpatulouseustachiantubesubjectsaretrospectivecasecontrolstudy
AT mcintyregraham transmissionofanovelsonotubometryacousticclickstimulusinhealthyandpatulouseustachiantubesubjectsaretrospectivecasecontrolstudy
AT butlermichaelb transmissionofanovelsonotubometryacousticclickstimulusinhealthyandpatulouseustachiantubesubjectsaretrospectivecasecontrolstudy
AT bancemanohar transmissionofanovelsonotubometryacousticclickstimulusinhealthyandpatulouseustachiantubesubjectsaretrospectivecasecontrolstudy