Cargando…
Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya
BACKGROUND: Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold cha...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5473550/ https://www.ncbi.nlm.nih.gov/pubmed/28622370 http://dx.doi.org/10.1371/journal.pone.0179316 |
_version_ | 1783244306448908288 |
---|---|
author | Zeh, Clement Ndiege, Kenneth Inzaule, Seth Achieng, Rebecca Williamson, John Chih-Wei Chang, Joy Ellenberger, Dennis Nkengasong, John |
author_facet | Zeh, Clement Ndiege, Kenneth Inzaule, Seth Achieng, Rebecca Williamson, John Chih-Wei Chang, Joy Ellenberger, Dennis Nkengasong, John |
author_sort | Zeh, Clement |
collection | PubMed |
description | BACKGROUND: Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. METHODS: Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). RESULTS: Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2–99.2] and 98.1% [95%CI: 89.7–100]) and those for DBS (93.9% [95%CI: 88.8–97.2] and 88.0% [95%CI: 82.2–92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r(2) = 90.5 and r(c) = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4–97.7) and 73.6 (95%CI: 51.6–86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6–100.0] vs. 94.7% [95%CI: 89.8–97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4–13.7] compared to DPS: 94.0%, [95% CI: 83.5–98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8–98.7] and 90.4% [95% CI 78.2–96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3–97.5] and 98.1% [95%CI 88.4–99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0–98.3] and specificity of 82.7% [95%CI 69.2–91.3]). CONCLUSIONS: There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings. |
format | Online Article Text |
id | pubmed-5473550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-54735502017-06-22 Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya Zeh, Clement Ndiege, Kenneth Inzaule, Seth Achieng, Rebecca Williamson, John Chih-Wei Chang, Joy Ellenberger, Dennis Nkengasong, John PLoS One Research Article BACKGROUND: Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. METHODS: Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). RESULTS: Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2–99.2] and 98.1% [95%CI: 89.7–100]) and those for DBS (93.9% [95%CI: 88.8–97.2] and 88.0% [95%CI: 82.2–92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r(2) = 90.5 and r(c) = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4–97.7) and 73.6 (95%CI: 51.6–86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6–100.0] vs. 94.7% [95%CI: 89.8–97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4–13.7] compared to DPS: 94.0%, [95% CI: 83.5–98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8–98.7] and 90.4% [95% CI 78.2–96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3–97.5] and 98.1% [95%CI 88.4–99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0–98.3] and specificity of 82.7% [95%CI 69.2–91.3]). CONCLUSIONS: There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings. Public Library of Science 2017-06-16 /pmc/articles/PMC5473550/ /pubmed/28622370 http://dx.doi.org/10.1371/journal.pone.0179316 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication. |
spellingShingle | Research Article Zeh, Clement Ndiege, Kenneth Inzaule, Seth Achieng, Rebecca Williamson, John Chih-Wei Chang, Joy Ellenberger, Dennis Nkengasong, John Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya |
title | Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya |
title_full | Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya |
title_fullStr | Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya |
title_full_unstemmed | Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya |
title_short | Evaluation of the performance of Abbott m2000 and Roche COBAS Ampliprep/COBAS Taqman assays for HIV-1 viral load determination using dried blood spots and dried plasma spots in Kenya |
title_sort | evaluation of the performance of abbott m2000 and roche cobas ampliprep/cobas taqman assays for hiv-1 viral load determination using dried blood spots and dried plasma spots in kenya |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5473550/ https://www.ncbi.nlm.nih.gov/pubmed/28622370 http://dx.doi.org/10.1371/journal.pone.0179316 |
work_keys_str_mv | AT zehclement evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT ndiegekenneth evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT inzauleseth evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT achiengrebecca evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT williamsonjohn evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT chihweichangjoy evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT ellenbergerdennis evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya AT nkengasongjohn evaluationoftheperformanceofabbottm2000androchecobasampliprepcobastaqmanassaysforhiv1viralloaddeterminationusingdriedbloodspotsanddriedplasmaspotsinkenya |