Cargando…
ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR
OBJECTIVE: To investigate the safety and efficacy of allogeneic platelet-rich plasma (PRP) in rotator cuff repair. METHODS: Seventeen patients with a full-thickness rotator cuff tear were included. Ten patients underwent arthroscopic rotator cuff repair with allogeneic, and seven patients with autol...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Departamento de Ortopedia e Traumatologia (DOT/FMUSP)
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5474401/ https://www.ncbi.nlm.nih.gov/pubmed/28642649 http://dx.doi.org/10.1590/1413-785220172501163417 |
_version_ | 1783244437045903360 |
---|---|
author | JO, CHRIS HYUNCHUL SHIN, JI SUN LEE, SEUNG YEON SHIN, SUE |
author_facet | JO, CHRIS HYUNCHUL SHIN, JI SUN LEE, SEUNG YEON SHIN, SUE |
author_sort | JO, CHRIS HYUNCHUL |
collection | PubMed |
description | OBJECTIVE: To investigate the safety and efficacy of allogeneic platelet-rich plasma (PRP) in rotator cuff repair. METHODS: Seventeen patients with a full-thickness rotator cuff tear were included. Ten patients underwent arthroscopic rotator cuff repair with allogeneic, and seven patients with autologous PRP. Three PRP gels in a volume 3 ml each were applied between the torn end and the greater tuberosity. Clinical outcomes were assessed preoperatively and at a minimum of 2 years after surgery. Structural outcomes were evaluated with the presence of retear and the change of the cross-sectional area (ACT) of the supraspinatus. RESULTS: Allogeneic PRP did not cause any adverse events during the follow-up period. There was no significant difference in the clinical outcome measures between the two groups (all p > 0.05). The retear rate was 33.3% and 25.0% in the allogeneic group and autologous group, respectively (p = 0.764). The change between the one-year postoperative and immediately postoperative ACT was not also significantly different between the two groups (p = 0.373). CONCLUSION: Allogeneic PRP in arthroscopic rotator cuff did not cause any local or general complications and that has the efficacy comparable to autologous PRP with respect to the clinical and structural outcomes.Level of Evidence III, Retrospective Comparative Study. |
format | Online Article Text |
id | pubmed-5474401 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Departamento de Ortopedia e Traumatologia (DOT/FMUSP) |
record_format | MEDLINE/PubMed |
spelling | pubmed-54744012017-06-22 ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR JO, CHRIS HYUNCHUL SHIN, JI SUN LEE, SEUNG YEON SHIN, SUE Acta Ortop Bras Original Articles OBJECTIVE: To investigate the safety and efficacy of allogeneic platelet-rich plasma (PRP) in rotator cuff repair. METHODS: Seventeen patients with a full-thickness rotator cuff tear were included. Ten patients underwent arthroscopic rotator cuff repair with allogeneic, and seven patients with autologous PRP. Three PRP gels in a volume 3 ml each were applied between the torn end and the greater tuberosity. Clinical outcomes were assessed preoperatively and at a minimum of 2 years after surgery. Structural outcomes were evaluated with the presence of retear and the change of the cross-sectional area (ACT) of the supraspinatus. RESULTS: Allogeneic PRP did not cause any adverse events during the follow-up period. There was no significant difference in the clinical outcome measures between the two groups (all p > 0.05). The retear rate was 33.3% and 25.0% in the allogeneic group and autologous group, respectively (p = 0.764). The change between the one-year postoperative and immediately postoperative ACT was not also significantly different between the two groups (p = 0.373). CONCLUSION: Allogeneic PRP in arthroscopic rotator cuff did not cause any local or general complications and that has the efficacy comparable to autologous PRP with respect to the clinical and structural outcomes.Level of Evidence III, Retrospective Comparative Study. Departamento de Ortopedia e Traumatologia (DOT/FMUSP) 2017 /pmc/articles/PMC5474401/ /pubmed/28642649 http://dx.doi.org/10.1590/1413-785220172501163417 Text en http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License |
spellingShingle | Original Articles JO, CHRIS HYUNCHUL SHIN, JI SUN LEE, SEUNG YEON SHIN, SUE ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR |
title | ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR |
title_full | ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR |
title_fullStr | ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR |
title_full_unstemmed | ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR |
title_short | ALLOGENEIC PLATELET-RICH PLASMA FOR ROTATOR CUFF REPAIR |
title_sort | allogeneic platelet-rich plasma for rotator cuff repair |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5474401/ https://www.ncbi.nlm.nih.gov/pubmed/28642649 http://dx.doi.org/10.1590/1413-785220172501163417 |
work_keys_str_mv | AT jochrishyunchul allogeneicplateletrichplasmaforrotatorcuffrepair AT shinjisun allogeneicplateletrichplasmaforrotatorcuffrepair AT leeseungyeon allogeneicplateletrichplasmaforrotatorcuffrepair AT shinsue allogeneicplateletrichplasmaforrotatorcuffrepair |