Cargando…
Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
Rapid point-of-care, antibody-based testing is not currently available for the diagnosis of most autoimmune and infectious diseases. Here we report a simple, robust and ultrafast fluid-phase immunocapture method for clinical measurements of antibody levels. This method employs neodymium magnetic sti...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476601/ https://www.ncbi.nlm.nih.gov/pubmed/28630417 http://dx.doi.org/10.1038/s41598-017-03786-7 |
_version_ | 1783244619180408832 |
---|---|
author | Burbelo, Peter D. Gunti, Sreenivasulu Keller, Jason M. Morse, Caryn G. Deeks, Steven G. Lionakis, Michail S. Kapoor, Amit Li, Qingxue Cohen, Jeffrey I. Notkins, Abner L. Alevizos, Ilias |
author_facet | Burbelo, Peter D. Gunti, Sreenivasulu Keller, Jason M. Morse, Caryn G. Deeks, Steven G. Lionakis, Michail S. Kapoor, Amit Li, Qingxue Cohen, Jeffrey I. Notkins, Abner L. Alevizos, Ilias |
author_sort | Burbelo, Peter D. |
collection | PubMed |
description | Rapid point-of-care, antibody-based testing is not currently available for the diagnosis of most autoimmune and infectious diseases. Here we report a simple, robust and ultrafast fluid-phase immunocapture method for clinical measurements of antibody levels. This method employs neodymium magnetic sticks that capture protein A/G-coated paramagnetic beads bound to antibody-luciferase-labeled antigen complexes. We demonstrate the ability to effectively measure specific antibody levels in serum samples from patients with varied infectious or autoimmune disorders, and in the case of Sjögren’s syndrome directly in saliva, requiring about a minute per assay. We also show the feasibility of coupling this method with a hand-held luminometer for portable testing. Our method offers the potential to quickly diagnose a multitude of autoimmune and infectious diseases in point-of-care settings. |
format | Online Article Text |
id | pubmed-5476601 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-54766012017-06-23 Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes Burbelo, Peter D. Gunti, Sreenivasulu Keller, Jason M. Morse, Caryn G. Deeks, Steven G. Lionakis, Michail S. Kapoor, Amit Li, Qingxue Cohen, Jeffrey I. Notkins, Abner L. Alevizos, Ilias Sci Rep Article Rapid point-of-care, antibody-based testing is not currently available for the diagnosis of most autoimmune and infectious diseases. Here we report a simple, robust and ultrafast fluid-phase immunocapture method for clinical measurements of antibody levels. This method employs neodymium magnetic sticks that capture protein A/G-coated paramagnetic beads bound to antibody-luciferase-labeled antigen complexes. We demonstrate the ability to effectively measure specific antibody levels in serum samples from patients with varied infectious or autoimmune disorders, and in the case of Sjögren’s syndrome directly in saliva, requiring about a minute per assay. We also show the feasibility of coupling this method with a hand-held luminometer for portable testing. Our method offers the potential to quickly diagnose a multitude of autoimmune and infectious diseases in point-of-care settings. Nature Publishing Group UK 2017-06-19 /pmc/articles/PMC5476601/ /pubmed/28630417 http://dx.doi.org/10.1038/s41598-017-03786-7 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Burbelo, Peter D. Gunti, Sreenivasulu Keller, Jason M. Morse, Caryn G. Deeks, Steven G. Lionakis, Michail S. Kapoor, Amit Li, Qingxue Cohen, Jeffrey I. Notkins, Abner L. Alevizos, Ilias Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes |
title | Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes |
title_full | Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes |
title_fullStr | Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes |
title_full_unstemmed | Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes |
title_short | Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes |
title_sort | ultrarapid measurement of diagnostic antibodies by magnetic capture of immune complexes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476601/ https://www.ncbi.nlm.nih.gov/pubmed/28630417 http://dx.doi.org/10.1038/s41598-017-03786-7 |
work_keys_str_mv | AT burbelopeterd ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT guntisreenivasulu ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT kellerjasonm ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT morsecaryng ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT deekssteveng ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT lionakismichails ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT kapooramit ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT liqingxue ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT cohenjeffreyi ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT notkinsabnerl ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes AT alevizosilias ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes |