Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes

Rapid point-of-care, antibody-based testing is not currently available for the diagnosis of most autoimmune and infectious diseases. Here we report a simple, robust and ultrafast fluid-phase immunocapture method for clinical measurements of antibody levels. This method employs neodymium magnetic sti...

Descripción completa

Detalles Bibliográficos
Autores principales: Burbelo, Peter D., Gunti, Sreenivasulu, Keller, Jason M., Morse, Caryn G., Deeks, Steven G., Lionakis, Michail S., Kapoor, Amit, Li, Qingxue, Cohen, Jeffrey I., Notkins, Abner L., Alevizos, Ilias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476601/
https://www.ncbi.nlm.nih.gov/pubmed/28630417
http://dx.doi.org/10.1038/s41598-017-03786-7
_version_ 1783244619180408832
author Burbelo, Peter D.
Gunti, Sreenivasulu
Keller, Jason M.
Morse, Caryn G.
Deeks, Steven G.
Lionakis, Michail S.
Kapoor, Amit
Li, Qingxue
Cohen, Jeffrey I.
Notkins, Abner L.
Alevizos, Ilias
author_facet Burbelo, Peter D.
Gunti, Sreenivasulu
Keller, Jason M.
Morse, Caryn G.
Deeks, Steven G.
Lionakis, Michail S.
Kapoor, Amit
Li, Qingxue
Cohen, Jeffrey I.
Notkins, Abner L.
Alevizos, Ilias
author_sort Burbelo, Peter D.
collection PubMed
description Rapid point-of-care, antibody-based testing is not currently available for the diagnosis of most autoimmune and infectious diseases. Here we report a simple, robust and ultrafast fluid-phase immunocapture method for clinical measurements of antibody levels. This method employs neodymium magnetic sticks that capture protein A/G-coated paramagnetic beads bound to antibody-luciferase-labeled antigen complexes. We demonstrate the ability to effectively measure specific antibody levels in serum samples from patients with varied infectious or autoimmune disorders, and in the case of Sjögren’s syndrome directly in saliva, requiring about a minute per assay. We also show the feasibility of coupling this method with a hand-held luminometer for portable testing. Our method offers the potential to quickly diagnose a multitude of autoimmune and infectious diseases in point-of-care settings.
format Online
Article
Text
id pubmed-5476601
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-54766012017-06-23 Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes Burbelo, Peter D. Gunti, Sreenivasulu Keller, Jason M. Morse, Caryn G. Deeks, Steven G. Lionakis, Michail S. Kapoor, Amit Li, Qingxue Cohen, Jeffrey I. Notkins, Abner L. Alevizos, Ilias Sci Rep Article Rapid point-of-care, antibody-based testing is not currently available for the diagnosis of most autoimmune and infectious diseases. Here we report a simple, robust and ultrafast fluid-phase immunocapture method for clinical measurements of antibody levels. This method employs neodymium magnetic sticks that capture protein A/G-coated paramagnetic beads bound to antibody-luciferase-labeled antigen complexes. We demonstrate the ability to effectively measure specific antibody levels in serum samples from patients with varied infectious or autoimmune disorders, and in the case of Sjögren’s syndrome directly in saliva, requiring about a minute per assay. We also show the feasibility of coupling this method with a hand-held luminometer for portable testing. Our method offers the potential to quickly diagnose a multitude of autoimmune and infectious diseases in point-of-care settings. Nature Publishing Group UK 2017-06-19 /pmc/articles/PMC5476601/ /pubmed/28630417 http://dx.doi.org/10.1038/s41598-017-03786-7 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Burbelo, Peter D.
Gunti, Sreenivasulu
Keller, Jason M.
Morse, Caryn G.
Deeks, Steven G.
Lionakis, Michail S.
Kapoor, Amit
Li, Qingxue
Cohen, Jeffrey I.
Notkins, Abner L.
Alevizos, Ilias
Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
title Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
title_full Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
title_fullStr Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
title_full_unstemmed Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
title_short Ultrarapid Measurement of Diagnostic Antibodies by Magnetic Capture of Immune Complexes
title_sort ultrarapid measurement of diagnostic antibodies by magnetic capture of immune complexes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476601/
https://www.ncbi.nlm.nih.gov/pubmed/28630417
http://dx.doi.org/10.1038/s41598-017-03786-7
work_keys_str_mv AT burbelopeterd ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT guntisreenivasulu ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT kellerjasonm ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT morsecaryng ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT deekssteveng ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT lionakismichails ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT kapooramit ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT liqingxue ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT cohenjeffreyi ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT notkinsabnerl ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes
AT alevizosilias ultrarapidmeasurementofdiagnosticantibodiesbymagneticcaptureofimmunecomplexes