Cargando…

Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction

BACKGROUND AND OBJECTIVE: Over the past decade, image quality in low-dose computed tomography has been greatly improved by various compressive sensing- (CS-) based reconstruction methods. However, these methods have some disadvantages including high computational cost and slow convergence rate. Many...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Hsuan-Ming, Hsiao, Ing-Tsung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476837/
https://www.ncbi.nlm.nih.gov/pubmed/28676860
http://dx.doi.org/10.1155/2017/6753831
_version_ 1783244674881814528
author Huang, Hsuan-Ming
Hsiao, Ing-Tsung
author_facet Huang, Hsuan-Ming
Hsiao, Ing-Tsung
author_sort Huang, Hsuan-Ming
collection PubMed
description BACKGROUND AND OBJECTIVE: Over the past decade, image quality in low-dose computed tomography has been greatly improved by various compressive sensing- (CS-) based reconstruction methods. However, these methods have some disadvantages including high computational cost and slow convergence rate. Many different speed-up techniques for CS-based reconstruction algorithms have been developed. The purpose of this paper is to propose a fast reconstruction framework that combines a CS-based reconstruction algorithm with several speed-up techniques. METHODS: First, total difference minimization (TDM) was implemented using the soft-threshold filtering (STF). Second, we combined TDM-STF with the ordered subsets transmission (OSTR) algorithm for accelerating the convergence. To further speed up the convergence of the proposed method, we applied the power factor and the fast iterative shrinkage thresholding algorithm to OSTR and TDM-STF, respectively. RESULTS: Results obtained from simulation and phantom studies showed that many speed-up techniques could be combined to greatly improve the convergence speed of a CS-based reconstruction algorithm. More importantly, the increased computation time (≤10%) was minor as compared to the acceleration provided by the proposed method. CONCLUSIONS: In this paper, we have presented a CS-based reconstruction framework that combines several acceleration techniques. Both simulation and phantom studies provide evidence that the proposed method has the potential to satisfy the requirement of fast image reconstruction in practical CT.
format Online
Article
Text
id pubmed-5476837
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54768372017-07-04 Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction Huang, Hsuan-Ming Hsiao, Ing-Tsung Biomed Res Int Research Article BACKGROUND AND OBJECTIVE: Over the past decade, image quality in low-dose computed tomography has been greatly improved by various compressive sensing- (CS-) based reconstruction methods. However, these methods have some disadvantages including high computational cost and slow convergence rate. Many different speed-up techniques for CS-based reconstruction algorithms have been developed. The purpose of this paper is to propose a fast reconstruction framework that combines a CS-based reconstruction algorithm with several speed-up techniques. METHODS: First, total difference minimization (TDM) was implemented using the soft-threshold filtering (STF). Second, we combined TDM-STF with the ordered subsets transmission (OSTR) algorithm for accelerating the convergence. To further speed up the convergence of the proposed method, we applied the power factor and the fast iterative shrinkage thresholding algorithm to OSTR and TDM-STF, respectively. RESULTS: Results obtained from simulation and phantom studies showed that many speed-up techniques could be combined to greatly improve the convergence speed of a CS-based reconstruction algorithm. More importantly, the increased computation time (≤10%) was minor as compared to the acceleration provided by the proposed method. CONCLUSIONS: In this paper, we have presented a CS-based reconstruction framework that combines several acceleration techniques. Both simulation and phantom studies provide evidence that the proposed method has the potential to satisfy the requirement of fast image reconstruction in practical CT. Hindawi 2017 2017-06-05 /pmc/articles/PMC5476837/ /pubmed/28676860 http://dx.doi.org/10.1155/2017/6753831 Text en Copyright © 2017 Hsuan-Ming Huang and Ing-Tsung Hsiao. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Huang, Hsuan-Ming
Hsiao, Ing-Tsung
Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
title Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
title_full Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
title_fullStr Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
title_full_unstemmed Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
title_short Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
title_sort combining acceleration techniques for low-dose x-ray cone beam computed tomography image reconstruction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476837/
https://www.ncbi.nlm.nih.gov/pubmed/28676860
http://dx.doi.org/10.1155/2017/6753831
work_keys_str_mv AT huanghsuanming combiningaccelerationtechniquesforlowdosexrayconebeamcomputedtomographyimagereconstruction
AT hsiaoingtsung combiningaccelerationtechniquesforlowdosexrayconebeamcomputedtomographyimagereconstruction