Cargando…
Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines
Two types of optical choppers for time-resolved measurements at synchrotron radiation soft X-ray beamlines have been developed. One type uses an air-spindle-type rotation mechanism with a two-stage differential pumping system to maintain the ultra-high vacuum of the X-ray beamline, and the other use...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5477479/ https://www.ncbi.nlm.nih.gov/pubmed/28452746 http://dx.doi.org/10.1107/S1600577517002399 |
_version_ | 1783244801267728384 |
---|---|
author | Osawa, Hitoshi Ohkochi, Takuo Fujisawa, Masami Kimura, Shigeru Kinoshita, Toyohiko |
author_facet | Osawa, Hitoshi Ohkochi, Takuo Fujisawa, Masami Kimura, Shigeru Kinoshita, Toyohiko |
author_sort | Osawa, Hitoshi |
collection | PubMed |
description | Two types of optical choppers for time-resolved measurements at synchrotron radiation soft X-ray beamlines have been developed. One type uses an air-spindle-type rotation mechanism with a two-stage differential pumping system to maintain the ultra-high vacuum of the X-ray beamline, and the other uses a magnetic bearing. Both can be installed at the soft X-ray beamlines at SPring-8, greatly improving the accessibility of pump-and-probe spectroscopy. The combination of X-ray chopper and pump-and-probe photoemission electron microscope at SPring-8 provides drastic improvements in signal-to-noise ratio and resolution compared with techniques using high-voltage gating of channel plate detectors. The choppers have the capability to be used not only at synchrotron radiation facilities but also at other types of soft X-ray and VUV beamlines. |
format | Online Article Text |
id | pubmed-5477479 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-54774792017-06-27 Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines Osawa, Hitoshi Ohkochi, Takuo Fujisawa, Masami Kimura, Shigeru Kinoshita, Toyohiko J Synchrotron Radiat Research Papers Two types of optical choppers for time-resolved measurements at synchrotron radiation soft X-ray beamlines have been developed. One type uses an air-spindle-type rotation mechanism with a two-stage differential pumping system to maintain the ultra-high vacuum of the X-ray beamline, and the other uses a magnetic bearing. Both can be installed at the soft X-ray beamlines at SPring-8, greatly improving the accessibility of pump-and-probe spectroscopy. The combination of X-ray chopper and pump-and-probe photoemission electron microscope at SPring-8 provides drastic improvements in signal-to-noise ratio and resolution compared with techniques using high-voltage gating of channel plate detectors. The choppers have the capability to be used not only at synchrotron radiation facilities but also at other types of soft X-ray and VUV beamlines. International Union of Crystallography 2017-03-20 /pmc/articles/PMC5477479/ /pubmed/28452746 http://dx.doi.org/10.1107/S1600577517002399 Text en © Hitoshi Osawa et al. 2017 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/2.0/uk/ |
spellingShingle | Research Papers Osawa, Hitoshi Ohkochi, Takuo Fujisawa, Masami Kimura, Shigeru Kinoshita, Toyohiko Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines |
title | Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines |
title_full | Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines |
title_fullStr | Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines |
title_full_unstemmed | Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines |
title_short | Development of optical choppers for time-resolved measurements at soft X-ray synchrotron radiation beamlines |
title_sort | development of optical choppers for time-resolved measurements at soft x-ray synchrotron radiation beamlines |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5477479/ https://www.ncbi.nlm.nih.gov/pubmed/28452746 http://dx.doi.org/10.1107/S1600577517002399 |
work_keys_str_mv | AT osawahitoshi developmentofopticalchoppersfortimeresolvedmeasurementsatsoftxraysynchrotronradiationbeamlines AT ohkochitakuo developmentofopticalchoppersfortimeresolvedmeasurementsatsoftxraysynchrotronradiationbeamlines AT fujisawamasami developmentofopticalchoppersfortimeresolvedmeasurementsatsoftxraysynchrotronradiationbeamlines AT kimurashigeru developmentofopticalchoppersfortimeresolvedmeasurementsatsoftxraysynchrotronradiationbeamlines AT kinoshitatoyohiko developmentofopticalchoppersfortimeresolvedmeasurementsatsoftxraysynchrotronradiationbeamlines |