Non-contact luminescence lifetime cryothermometry for macromolecular crystallography

Temperature is a very important parameter when aiming to minimize radiation damage to biological samples during experiments that utilize intense ionizing radiation. A novel technique for remote, non-contact, in situ monitoring of the protein crystal temperature has been developed for the new I23 bea...

Descripción completa

Detalles Bibliográficos
Autores principales: Mykhaylyk, V. B., Wagner, A., Kraus, H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5477482/
https://www.ncbi.nlm.nih.gov/pubmed/28452755
http://dx.doi.org/10.1107/S1600577517003484
_version_ 1783244801965031424
author Mykhaylyk, V. B.
Wagner, A.
Kraus, H.
author_facet Mykhaylyk, V. B.
Wagner, A.
Kraus, H.
author_sort Mykhaylyk, V. B.
collection PubMed
description Temperature is a very important parameter when aiming to minimize radiation damage to biological samples during experiments that utilize intense ionizing radiation. A novel technique for remote, non-contact, in situ monitoring of the protein crystal temperature has been developed for the new I23 beamline at the Diamond Light Source, a facility dedicated to macromolecular crystallography (MX) with long-wavelength X-rays. The temperature is derived from the temperature-dependent decay time constant of luminescence from a minuscule scintillation sensor (<0.05 mm(3)) located in very close proximity to the sample under test. In this work the underlying principle of cryogenic luminescence lifetime thermometry is presented, the features of the detection method and the choice of temperature sensor are discussed, and it is demonstrated how the temperature monitoring system was integrated within the viewing system of the endstation used for the visualization of protein crystals. The thermometry system was characterized using a Bi(4)Ge(3)O(12) crystal scintillator that exhibits good responsivity of the decay time constant as a function of temperature over a wide range (8–270 K). The scintillation sensor was calibrated and the uncertainty of the temperature measurements over the primary operation temperature range of the beamline (30–150 K) was assessed to be ±1.6 K. It has been shown that the temperature of the sample holder, measured using the luminescence sensor, agrees well with the expected value. The technique was applied to characterize the thermal performance of different sample mounts that have been used in MX experiments at the I23 beamline. The thickness of the mount is shown to have the greatest impact upon the temperature distribution across the sample mount. Altogether, these tests and findings demonstrate the usefulness of the thermometry system in highlighting the challenges that remain to be addressed for the in-vacuum MX experiment to become a reliable and indispensable tool for structural biology.
format Online
Article
Text
id pubmed-5477482
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-54774822017-06-27 Non-contact luminescence lifetime cryothermometry for macromolecular crystallography Mykhaylyk, V. B. Wagner, A. Kraus, H. J Synchrotron Radiat Research Papers Temperature is a very important parameter when aiming to minimize radiation damage to biological samples during experiments that utilize intense ionizing radiation. A novel technique for remote, non-contact, in situ monitoring of the protein crystal temperature has been developed for the new I23 beamline at the Diamond Light Source, a facility dedicated to macromolecular crystallography (MX) with long-wavelength X-rays. The temperature is derived from the temperature-dependent decay time constant of luminescence from a minuscule scintillation sensor (<0.05 mm(3)) located in very close proximity to the sample under test. In this work the underlying principle of cryogenic luminescence lifetime thermometry is presented, the features of the detection method and the choice of temperature sensor are discussed, and it is demonstrated how the temperature monitoring system was integrated within the viewing system of the endstation used for the visualization of protein crystals. The thermometry system was characterized using a Bi(4)Ge(3)O(12) crystal scintillator that exhibits good responsivity of the decay time constant as a function of temperature over a wide range (8–270 K). The scintillation sensor was calibrated and the uncertainty of the temperature measurements over the primary operation temperature range of the beamline (30–150 K) was assessed to be ±1.6 K. It has been shown that the temperature of the sample holder, measured using the luminescence sensor, agrees well with the expected value. The technique was applied to characterize the thermal performance of different sample mounts that have been used in MX experiments at the I23 beamline. The thickness of the mount is shown to have the greatest impact upon the temperature distribution across the sample mount. Altogether, these tests and findings demonstrate the usefulness of the thermometry system in highlighting the challenges that remain to be addressed for the in-vacuum MX experiment to become a reliable and indispensable tool for structural biology. International Union of Crystallography 2017-04-04 /pmc/articles/PMC5477482/ /pubmed/28452755 http://dx.doi.org/10.1107/S1600577517003484 Text en © V. B. Mykhaylyk et al. 2017 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.http://creativecommons.org/licenses/by/2.0/uk/
spellingShingle Research Papers
Mykhaylyk, V. B.
Wagner, A.
Kraus, H.
Non-contact luminescence lifetime cryothermometry for macromolecular crystallography
title Non-contact luminescence lifetime cryothermometry for macromolecular crystallography
title_full Non-contact luminescence lifetime cryothermometry for macromolecular crystallography
title_fullStr Non-contact luminescence lifetime cryothermometry for macromolecular crystallography
title_full_unstemmed Non-contact luminescence lifetime cryothermometry for macromolecular crystallography
title_short Non-contact luminescence lifetime cryothermometry for macromolecular crystallography
title_sort non-contact luminescence lifetime cryothermometry for macromolecular crystallography
topic Research Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5477482/
https://www.ncbi.nlm.nih.gov/pubmed/28452755
http://dx.doi.org/10.1107/S1600577517003484
work_keys_str_mv AT mykhaylykvb noncontactluminescencelifetimecryothermometryformacromolecularcrystallography
AT wagnera noncontactluminescencelifetimecryothermometryformacromolecularcrystallography
AT kraush noncontactluminescencelifetimecryothermometryformacromolecularcrystallography