Cargando…

Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study

BACKGROUND: This prospective study aimed to compare clinical effects of intramedullary nailing guided by digital and conventional technologies in treatment of tibial fractures. MATERIAL/METHODS: Thirty-two patients (mean age 43 years, 18 males and 14 females) who were treated for tibial fractures fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Lin, Xu, Xian, Li, Xu, Wu, Wei, Cai, Junfeng, Lu, Qingyou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5478299/
https://www.ncbi.nlm.nih.gov/pubmed/28604652
http://dx.doi.org/10.12659/MSM.902261
_version_ 1783244935248478208
author Liu, Lin
Xu, Xian
Li, Xu
Wu, Wei
Cai, Junfeng
Lu, Qingyou
author_facet Liu, Lin
Xu, Xian
Li, Xu
Wu, Wei
Cai, Junfeng
Lu, Qingyou
author_sort Liu, Lin
collection PubMed
description BACKGROUND: This prospective study aimed to compare clinical effects of intramedullary nailing guided by digital and conventional technologies in treatment of tibial fractures. MATERIAL/METHODS: Thirty-two patients (mean age 43 years, 18 males and 14 females) who were treated for tibial fractures from October 2010 to October 2012 were enrolled. They were sequentially randomized to receive intramedullary nailing guided by either digital technology (digital group, n=16) or conventional technology (conventional group, n=16). The operation time, fluoroscopy times, fracture healing time, distance between the actual and planned insertion point, postoperative lower limb alignment, and functional recovery were recorded for all patients. RESULTS: The mean operation time in the digital group was 43.1±6.2 min compared with 48.7±8.3 min for the conventional technology (P=0.039). The fluoroscopy times and distance between the actual and planned insertion point were significantly lower in the digital group than in the conventional group (both P<0.001). The accuracy rate of the insertion point was 99.12% by digital technology. No difference was found in fracture healing time and good postoperative lower limb alignment between the digital and conventional groups (P=0.083 and P=0.310), as well as the effective rate (100% vs. 87.50%, P=0.144). CONCLUSIONS: Intramedullary nailing guided by digital technology has many advantages in treatment of tibial fractures compared to conventional technology, including shorter operation time, reduced fluoroscopy times, and decreased distance between the actual and planned insertion point of the intramedullary nail.
format Online
Article
Text
id pubmed-5478299
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-54782992017-06-29 Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study Liu, Lin Xu, Xian Li, Xu Wu, Wei Cai, Junfeng Lu, Qingyou Med Sci Monit Clinical Research BACKGROUND: This prospective study aimed to compare clinical effects of intramedullary nailing guided by digital and conventional technologies in treatment of tibial fractures. MATERIAL/METHODS: Thirty-two patients (mean age 43 years, 18 males and 14 females) who were treated for tibial fractures from October 2010 to October 2012 were enrolled. They were sequentially randomized to receive intramedullary nailing guided by either digital technology (digital group, n=16) or conventional technology (conventional group, n=16). The operation time, fluoroscopy times, fracture healing time, distance between the actual and planned insertion point, postoperative lower limb alignment, and functional recovery were recorded for all patients. RESULTS: The mean operation time in the digital group was 43.1±6.2 min compared with 48.7±8.3 min for the conventional technology (P=0.039). The fluoroscopy times and distance between the actual and planned insertion point were significantly lower in the digital group than in the conventional group (both P<0.001). The accuracy rate of the insertion point was 99.12% by digital technology. No difference was found in fracture healing time and good postoperative lower limb alignment between the digital and conventional groups (P=0.083 and P=0.310), as well as the effective rate (100% vs. 87.50%, P=0.144). CONCLUSIONS: Intramedullary nailing guided by digital technology has many advantages in treatment of tibial fractures compared to conventional technology, including shorter operation time, reduced fluoroscopy times, and decreased distance between the actual and planned insertion point of the intramedullary nail. International Scientific Literature, Inc. 2017-06-12 /pmc/articles/PMC5478299/ /pubmed/28604652 http://dx.doi.org/10.12659/MSM.902261 Text en © Med Sci Monit, 2017 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Liu, Lin
Xu, Xian
Li, Xu
Wu, Wei
Cai, Junfeng
Lu, Qingyou
Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
title Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
title_full Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
title_fullStr Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
title_full_unstemmed Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
title_short Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
title_sort comparison of tibial intramedullary nailing guided by digital technology versus conventional method: a prospective study
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5478299/
https://www.ncbi.nlm.nih.gov/pubmed/28604652
http://dx.doi.org/10.12659/MSM.902261
work_keys_str_mv AT liulin comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy
AT xuxian comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy
AT lixu comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy
AT wuwei comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy
AT caijunfeng comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy
AT luqingyou comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy