Cargando…
Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study
BACKGROUND: This prospective study aimed to compare clinical effects of intramedullary nailing guided by digital and conventional technologies in treatment of tibial fractures. MATERIAL/METHODS: Thirty-two patients (mean age 43 years, 18 males and 14 females) who were treated for tibial fractures fr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5478299/ https://www.ncbi.nlm.nih.gov/pubmed/28604652 http://dx.doi.org/10.12659/MSM.902261 |
_version_ | 1783244935248478208 |
---|---|
author | Liu, Lin Xu, Xian Li, Xu Wu, Wei Cai, Junfeng Lu, Qingyou |
author_facet | Liu, Lin Xu, Xian Li, Xu Wu, Wei Cai, Junfeng Lu, Qingyou |
author_sort | Liu, Lin |
collection | PubMed |
description | BACKGROUND: This prospective study aimed to compare clinical effects of intramedullary nailing guided by digital and conventional technologies in treatment of tibial fractures. MATERIAL/METHODS: Thirty-two patients (mean age 43 years, 18 males and 14 females) who were treated for tibial fractures from October 2010 to October 2012 were enrolled. They were sequentially randomized to receive intramedullary nailing guided by either digital technology (digital group, n=16) or conventional technology (conventional group, n=16). The operation time, fluoroscopy times, fracture healing time, distance between the actual and planned insertion point, postoperative lower limb alignment, and functional recovery were recorded for all patients. RESULTS: The mean operation time in the digital group was 43.1±6.2 min compared with 48.7±8.3 min for the conventional technology (P=0.039). The fluoroscopy times and distance between the actual and planned insertion point were significantly lower in the digital group than in the conventional group (both P<0.001). The accuracy rate of the insertion point was 99.12% by digital technology. No difference was found in fracture healing time and good postoperative lower limb alignment between the digital and conventional groups (P=0.083 and P=0.310), as well as the effective rate (100% vs. 87.50%, P=0.144). CONCLUSIONS: Intramedullary nailing guided by digital technology has many advantages in treatment of tibial fractures compared to conventional technology, including shorter operation time, reduced fluoroscopy times, and decreased distance between the actual and planned insertion point of the intramedullary nail. |
format | Online Article Text |
id | pubmed-5478299 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-54782992017-06-29 Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study Liu, Lin Xu, Xian Li, Xu Wu, Wei Cai, Junfeng Lu, Qingyou Med Sci Monit Clinical Research BACKGROUND: This prospective study aimed to compare clinical effects of intramedullary nailing guided by digital and conventional technologies in treatment of tibial fractures. MATERIAL/METHODS: Thirty-two patients (mean age 43 years, 18 males and 14 females) who were treated for tibial fractures from October 2010 to October 2012 were enrolled. They were sequentially randomized to receive intramedullary nailing guided by either digital technology (digital group, n=16) or conventional technology (conventional group, n=16). The operation time, fluoroscopy times, fracture healing time, distance between the actual and planned insertion point, postoperative lower limb alignment, and functional recovery were recorded for all patients. RESULTS: The mean operation time in the digital group was 43.1±6.2 min compared with 48.7±8.3 min for the conventional technology (P=0.039). The fluoroscopy times and distance between the actual and planned insertion point were significantly lower in the digital group than in the conventional group (both P<0.001). The accuracy rate of the insertion point was 99.12% by digital technology. No difference was found in fracture healing time and good postoperative lower limb alignment between the digital and conventional groups (P=0.083 and P=0.310), as well as the effective rate (100% vs. 87.50%, P=0.144). CONCLUSIONS: Intramedullary nailing guided by digital technology has many advantages in treatment of tibial fractures compared to conventional technology, including shorter operation time, reduced fluoroscopy times, and decreased distance between the actual and planned insertion point of the intramedullary nail. International Scientific Literature, Inc. 2017-06-12 /pmc/articles/PMC5478299/ /pubmed/28604652 http://dx.doi.org/10.12659/MSM.902261 Text en © Med Sci Monit, 2017 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Liu, Lin Xu, Xian Li, Xu Wu, Wei Cai, Junfeng Lu, Qingyou Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study |
title | Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study |
title_full | Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study |
title_fullStr | Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study |
title_full_unstemmed | Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study |
title_short | Comparison of Tibial Intramedullary Nailing Guided by Digital Technology Versus Conventional Method: A Prospective Study |
title_sort | comparison of tibial intramedullary nailing guided by digital technology versus conventional method: a prospective study |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5478299/ https://www.ncbi.nlm.nih.gov/pubmed/28604652 http://dx.doi.org/10.12659/MSM.902261 |
work_keys_str_mv | AT liulin comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy AT xuxian comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy AT lixu comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy AT wuwei comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy AT caijunfeng comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy AT luqingyou comparisonoftibialintramedullarynailingguidedbydigitaltechnologyversusconventionalmethodaprospectivestudy |