Cargando…

Influence of study design on digital pathology image quality evaluation: the need to define a clinical task

Despite the current rapid advance in technologies for whole slide imaging, there is still no scientific consensus on the recommended methodology for image quality assessment of digital pathology slides. For medical images in general, it has been recommended to assess image quality in terms of doctor...

Descripción completa

Detalles Bibliográficos
Autores principales: Platiša, Ljiljana, Brantegem, Leen Van, Kumcu, Asli, Ducatelle, Richard, Philips, Wilfried
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5478946/
https://www.ncbi.nlm.nih.gov/pubmed/28653011
http://dx.doi.org/10.1117/1.JMI.4.2.021108
_version_ 1783245053562454016
author Platiša, Ljiljana
Brantegem, Leen Van
Kumcu, Asli
Ducatelle, Richard
Philips, Wilfried
author_facet Platiša, Ljiljana
Brantegem, Leen Van
Kumcu, Asli
Ducatelle, Richard
Philips, Wilfried
author_sort Platiša, Ljiljana
collection PubMed
description Despite the current rapid advance in technologies for whole slide imaging, there is still no scientific consensus on the recommended methodology for image quality assessment of digital pathology slides. For medical images in general, it has been recommended to assess image quality in terms of doctors’ success rates in performing a specific clinical task while using the images (clinical image quality, cIQ). However, digital pathology is a new modality, and already identifying the appropriate task is difficult. In an alternative common approach, humans are asked to do a simpler task such as rating overall image quality (perceived image quality, pIQ), but that involves the risk of nonclinically relevant findings due to an unknown relationship between the pIQ and cIQ. In this study, we explored three different experimental protocols: (1) conducting a clinical task (detecting inclusion bodies), (2) rating image similarity and preference, and (3) rating the overall image quality. Additionally, within protocol 1, overall quality ratings were also collected (task-aware pIQ). The experiments were done by diagnostic veterinary pathologists in the context of evaluating the quality of hematoxylin and eosin-stained digital pathology slides of animal tissue samples under several common image alterations: additive noise, blurring, change in gamma, change in color saturation, and JPG compression. While the size of our experiments was small and prevents drawing strong conclusions, the results suggest the need to define a clinical task. Importantly, the pIQ data collected under protocols 2 and 3 did not always rank the image alterations the same as their cIQ from protocol 1, warning against using conventional pIQ to predict cIQ. At the same time, there was a correlation between the cIQ and task-aware pIQ ratings from protocol 1, suggesting that the clinical experiment context (set by specifying the clinical task) may affect human visual attention and bring focus to their criteria of image quality. Further research is needed to assess whether and for which purposes (e.g., preclinical testing) task-aware pIQ ratings could substitute cIQ for a given clinical task.
format Online
Article
Text
id pubmed-5478946
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-54789462018-06-21 Influence of study design on digital pathology image quality evaluation: the need to define a clinical task Platiša, Ljiljana Brantegem, Leen Van Kumcu, Asli Ducatelle, Richard Philips, Wilfried J Med Imaging (Bellingham) Special Section on Digital Pathology Despite the current rapid advance in technologies for whole slide imaging, there is still no scientific consensus on the recommended methodology for image quality assessment of digital pathology slides. For medical images in general, it has been recommended to assess image quality in terms of doctors’ success rates in performing a specific clinical task while using the images (clinical image quality, cIQ). However, digital pathology is a new modality, and already identifying the appropriate task is difficult. In an alternative common approach, humans are asked to do a simpler task such as rating overall image quality (perceived image quality, pIQ), but that involves the risk of nonclinically relevant findings due to an unknown relationship between the pIQ and cIQ. In this study, we explored three different experimental protocols: (1) conducting a clinical task (detecting inclusion bodies), (2) rating image similarity and preference, and (3) rating the overall image quality. Additionally, within protocol 1, overall quality ratings were also collected (task-aware pIQ). The experiments were done by diagnostic veterinary pathologists in the context of evaluating the quality of hematoxylin and eosin-stained digital pathology slides of animal tissue samples under several common image alterations: additive noise, blurring, change in gamma, change in color saturation, and JPG compression. While the size of our experiments was small and prevents drawing strong conclusions, the results suggest the need to define a clinical task. Importantly, the pIQ data collected under protocols 2 and 3 did not always rank the image alterations the same as their cIQ from protocol 1, warning against using conventional pIQ to predict cIQ. At the same time, there was a correlation between the cIQ and task-aware pIQ ratings from protocol 1, suggesting that the clinical experiment context (set by specifying the clinical task) may affect human visual attention and bring focus to their criteria of image quality. Further research is needed to assess whether and for which purposes (e.g., preclinical testing) task-aware pIQ ratings could substitute cIQ for a given clinical task. Society of Photo-Optical Instrumentation Engineers 2017-06-21 2017-04 /pmc/articles/PMC5478946/ /pubmed/28653011 http://dx.doi.org/10.1117/1.JMI.4.2.021108 Text en © The Authors. https://creativecommons.org/licenses/by/3.0/ Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle Special Section on Digital Pathology
Platiša, Ljiljana
Brantegem, Leen Van
Kumcu, Asli
Ducatelle, Richard
Philips, Wilfried
Influence of study design on digital pathology image quality evaluation: the need to define a clinical task
title Influence of study design on digital pathology image quality evaluation: the need to define a clinical task
title_full Influence of study design on digital pathology image quality evaluation: the need to define a clinical task
title_fullStr Influence of study design on digital pathology image quality evaluation: the need to define a clinical task
title_full_unstemmed Influence of study design on digital pathology image quality evaluation: the need to define a clinical task
title_short Influence of study design on digital pathology image quality evaluation: the need to define a clinical task
title_sort influence of study design on digital pathology image quality evaluation: the need to define a clinical task
topic Special Section on Digital Pathology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5478946/
https://www.ncbi.nlm.nih.gov/pubmed/28653011
http://dx.doi.org/10.1117/1.JMI.4.2.021108
work_keys_str_mv AT platisaljiljana influenceofstudydesignondigitalpathologyimagequalityevaluationtheneedtodefineaclinicaltask
AT brantegemleenvan influenceofstudydesignondigitalpathologyimagequalityevaluationtheneedtodefineaclinicaltask
AT kumcuasli influenceofstudydesignondigitalpathologyimagequalityevaluationtheneedtodefineaclinicaltask
AT ducatellerichard influenceofstudydesignondigitalpathologyimagequalityevaluationtheneedtodefineaclinicaltask
AT philipswilfried influenceofstudydesignondigitalpathologyimagequalityevaluationtheneedtodefineaclinicaltask