Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation

BACKGROUND: Expanded polytetrafluroethelyne (e PTFE, Gore-Tex(®)) has been advocated as an implant material for medialization of the vocal fold. Animal studies involving rabbits and a porcine model have demonstrated host tolerance of the implant. There have been no reports describing the histologica...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajkumar, K, Khalil, HS, Elloy, M, Sheffield, E, Baldwin, DL
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC547912/
https://www.ncbi.nlm.nih.gov/pubmed/15663781
http://dx.doi.org/10.1186/1472-6815-5-1
_version_ 1782122310762758144
author Rajkumar, K
Khalil, HS
Elloy, M
Sheffield, E
Baldwin, DL
author_facet Rajkumar, K
Khalil, HS
Elloy, M
Sheffield, E
Baldwin, DL
author_sort Rajkumar, K
collection PubMed
description BACKGROUND: Expanded polytetrafluroethelyne (e PTFE, Gore-Tex(®)) has been advocated as an implant material for medialization of the vocal fold. Animal studies involving rabbits and a porcine model have demonstrated host tolerance of the implant. There have been no reports describing the histological changes in a human laryngectomy specimen with a Gore-Tex implant. CASE PRESENTATION: The histological findings in a laryngectomy specimen of a patient previously implanted with e PTFE for medialization of a paralyzed vocal fold following excision of a vagal neurofibroma were studied. Histopathology revealed a mild foreign-body giant cell granulomatous reaction with some associated fibrosis. The granulomatous response was limited to the periphery of the Gore-Tex and although it closely followed the profile of the material it did not encroach into or significantly break up the material. There was no significant neutrophilic or lymphocytic inflammation. CONCLUSIONS: Our findings are consistent with the animal models confirming that Gore-Tex implantation does not result in a significant granulomatous reaction in the human larynx over a 13-month period. Moreover, there is no evidence of resorption or infection. Further, the lack of lymphocytes in association with the granulomas indicates that there is no significant immunological hypersensitivity. Histologically, the slight permeation by connective tissue is similar to that seen in Gore-Tex vascular and cardiac implants. The degree of the slight giant cell response appears to be dependent on the profile of the material; a sharp edge incited more of a response than a flat surface.
format Text
id pubmed-547912
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-5479122005-02-04 Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation Rajkumar, K Khalil, HS Elloy, M Sheffield, E Baldwin, DL BMC Ear Nose Throat Disord Case Report BACKGROUND: Expanded polytetrafluroethelyne (e PTFE, Gore-Tex(®)) has been advocated as an implant material for medialization of the vocal fold. Animal studies involving rabbits and a porcine model have demonstrated host tolerance of the implant. There have been no reports describing the histological changes in a human laryngectomy specimen with a Gore-Tex implant. CASE PRESENTATION: The histological findings in a laryngectomy specimen of a patient previously implanted with e PTFE for medialization of a paralyzed vocal fold following excision of a vagal neurofibroma were studied. Histopathology revealed a mild foreign-body giant cell granulomatous reaction with some associated fibrosis. The granulomatous response was limited to the periphery of the Gore-Tex and although it closely followed the profile of the material it did not encroach into or significantly break up the material. There was no significant neutrophilic or lymphocytic inflammation. CONCLUSIONS: Our findings are consistent with the animal models confirming that Gore-Tex implantation does not result in a significant granulomatous reaction in the human larynx over a 13-month period. Moreover, there is no evidence of resorption or infection. Further, the lack of lymphocytes in association with the granulomas indicates that there is no significant immunological hypersensitivity. Histologically, the slight permeation by connective tissue is similar to that seen in Gore-Tex vascular and cardiac implants. The degree of the slight giant cell response appears to be dependent on the profile of the material; a sharp edge incited more of a response than a flat surface. BioMed Central 2005-01-21 /pmc/articles/PMC547912/ /pubmed/15663781 http://dx.doi.org/10.1186/1472-6815-5-1 Text en Copyright © 2005 Rajkumar et al; licensee BioMed Central Ltd.
spellingShingle Case Report
Rajkumar, K
Khalil, HS
Elloy, M
Sheffield, E
Baldwin, DL
Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation
title Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation
title_full Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation
title_fullStr Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation
title_full_unstemmed Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation
title_short Histopathological changes in the human larynx following expanded polytetrafluroethylene (Gore-Tex(®)) implantation
title_sort histopathological changes in the human larynx following expanded polytetrafluroethylene (gore-tex(®)) implantation
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC547912/
https://www.ncbi.nlm.nih.gov/pubmed/15663781
http://dx.doi.org/10.1186/1472-6815-5-1
work_keys_str_mv AT rajkumark histopathologicalchangesinthehumanlarynxfollowingexpandedpolytetrafluroethylenegoreteximplantation
AT khalilhs histopathologicalchangesinthehumanlarynxfollowingexpandedpolytetrafluroethylenegoreteximplantation
AT elloym histopathologicalchangesinthehumanlarynxfollowingexpandedpolytetrafluroethylenegoreteximplantation
AT sheffielde histopathologicalchangesinthehumanlarynxfollowingexpandedpolytetrafluroethylenegoreteximplantation
AT baldwindl histopathologicalchangesinthehumanlarynxfollowingexpandedpolytetrafluroethylenegoreteximplantation