Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
INTRODUCTION: The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE: We report a 57-year-old w...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5479952/ https://www.ncbi.nlm.nih.gov/pubmed/28641194 http://dx.doi.org/10.1016/j.ijscr.2017.06.010 |
_version_ | 1783245200667181056 |
---|---|
author | Hatanaka, Hiroyuki Motomura, Goro Ikemura, Satoshi Sonoda, Kazuhiko Kubo, Yusuke Utsunomiya, Takeshi Yamamoto, Takuaki Nakashima, Yasuharu |
author_facet | Hatanaka, Hiroyuki Motomura, Goro Ikemura, Satoshi Sonoda, Kazuhiko Kubo, Yusuke Utsunomiya, Takeshi Yamamoto, Takuaki Nakashima, Yasuharu |
author_sort | Hatanaka, Hiroyuki |
collection | PubMed |
description | INTRODUCTION: The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE: We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. DISCUSSION: We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. CONCLUSION: This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP. |
format | Online Article Text |
id | pubmed-5479952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-54799522017-06-29 Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report Hatanaka, Hiroyuki Motomura, Goro Ikemura, Satoshi Sonoda, Kazuhiko Kubo, Yusuke Utsunomiya, Takeshi Yamamoto, Takuaki Nakashima, Yasuharu Int J Surg Case Rep Case Report INTRODUCTION: The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE: We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. DISCUSSION: We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. CONCLUSION: This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP. Elsevier 2017-06-13 /pmc/articles/PMC5479952/ /pubmed/28641194 http://dx.doi.org/10.1016/j.ijscr.2017.06.010 Text en © 2017 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Hatanaka, Hiroyuki Motomura, Goro Ikemura, Satoshi Sonoda, Kazuhiko Kubo, Yusuke Utsunomiya, Takeshi Yamamoto, Takuaki Nakashima, Yasuharu Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report |
title | Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report |
title_full | Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report |
title_fullStr | Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report |
title_full_unstemmed | Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report |
title_short | Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report |
title_sort | use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5479952/ https://www.ncbi.nlm.nih.gov/pubmed/28641194 http://dx.doi.org/10.1016/j.ijscr.2017.06.010 |
work_keys_str_mv | AT hatanakahiroyuki useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT motomuragoro useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT ikemurasatoshi useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT sonodakazuhiko useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT kuboyusuke useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT utsunomiyatakeshi useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT yamamototakuaki useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport AT nakashimayasuharu useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport |