Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report

INTRODUCTION: The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE: We report a 57-year-old w...

Descripción completa

Detalles Bibliográficos
Autores principales: Hatanaka, Hiroyuki, Motomura, Goro, Ikemura, Satoshi, Sonoda, Kazuhiko, Kubo, Yusuke, Utsunomiya, Takeshi, Yamamoto, Takuaki, Nakashima, Yasuharu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5479952/
https://www.ncbi.nlm.nih.gov/pubmed/28641194
http://dx.doi.org/10.1016/j.ijscr.2017.06.010
_version_ 1783245200667181056
author Hatanaka, Hiroyuki
Motomura, Goro
Ikemura, Satoshi
Sonoda, Kazuhiko
Kubo, Yusuke
Utsunomiya, Takeshi
Yamamoto, Takuaki
Nakashima, Yasuharu
author_facet Hatanaka, Hiroyuki
Motomura, Goro
Ikemura, Satoshi
Sonoda, Kazuhiko
Kubo, Yusuke
Utsunomiya, Takeshi
Yamamoto, Takuaki
Nakashima, Yasuharu
author_sort Hatanaka, Hiroyuki
collection PubMed
description INTRODUCTION: The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE: We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. DISCUSSION: We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. CONCLUSION: This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP.
format Online
Article
Text
id pubmed-5479952
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54799522017-06-29 Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report Hatanaka, Hiroyuki Motomura, Goro Ikemura, Satoshi Sonoda, Kazuhiko Kubo, Yusuke Utsunomiya, Takeshi Yamamoto, Takuaki Nakashima, Yasuharu Int J Surg Case Rep Case Report INTRODUCTION: The thrust plate hip prosthesis (TPP; Zimmer, Winterthur, Switzerland) is a hip prosthesis that is no longer in production. Few reports have focused on periprosthetic fractures following total hip arthroplasty (THA) with the use of a TPP. PRESENTATION OF CASE: We report a 57-year-old woman with a periprosthetic femoral fracture 13 years after THA with the use of a TPP. A plain radiograph showed a displaced subtrochanteric fracture of the right femur just below the distal tip of the lateral plate without implant loosening. She underwent revision surgery with a long distally fixed intramedullary stem in conjunction with a plate and cable system. Three months after surgery, bone union was confirmed using radiography and the patient was clinically asymptomatic. DISCUSSION: We encountered three major problems while planning surgical treatment, these being, discontinuation of the TPP system, loss of proximal femoral cancellous bone, and difficulties with the type of subtrochanteric fracture. After considering these problems, we planned revision surgery using a long distally fixed intramedullary stem in conjunction with a plate and cable system. CONCLUSION: This case shows that sufficient implant preparation based on precise preoperative planning is necessary to obtain good clinical results for the surgical treatment of periprosthetic femoral fractures following THA with the use of a TPP. Elsevier 2017-06-13 /pmc/articles/PMC5479952/ /pubmed/28641194 http://dx.doi.org/10.1016/j.ijscr.2017.06.010 Text en © 2017 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Hatanaka, Hiroyuki
Motomura, Goro
Ikemura, Satoshi
Sonoda, Kazuhiko
Kubo, Yusuke
Utsunomiya, Takeshi
Yamamoto, Takuaki
Nakashima, Yasuharu
Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
title Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
title_full Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
title_fullStr Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
title_full_unstemmed Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
title_short Use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: A case report
title_sort use of a long distally fixed intramedullary stem to treat a periprosthetic femoral fracture following total hip arthroplasty using a thrust plate hip prosthesis: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5479952/
https://www.ncbi.nlm.nih.gov/pubmed/28641194
http://dx.doi.org/10.1016/j.ijscr.2017.06.010
work_keys_str_mv AT hatanakahiroyuki useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT motomuragoro useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT ikemurasatoshi useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT sonodakazuhiko useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT kuboyusuke useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT utsunomiyatakeshi useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT yamamototakuaki useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport
AT nakashimayasuharu useofalongdistallyfixedintramedullarystemtotreataperiprostheticfemoralfracturefollowingtotalhiparthroplastyusingathrustplatehipprosthesisacasereport