Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles

BACKGROUND: Cone beam computed tomography (CBCT) has been largely used in dentistry. Nevertheless, there is lack of evidence regarding CBCT accuracy in the diagnosis of early periodontal lesions as well as the correlation between accuracy and lesion size. The aim of this study was to evaluate accura...

Descripción completa

Detalles Bibliográficos
Autores principales: Almeida, Vanessa Camillo, Pinheiro, Lucas Rodrigues, Salineiro, Fernanda Cristina Sales, Mendes, Fausto Medeiros, Neto, João Batista César, Cavalcanti, Marcelo Gusmão Paraíso, Pannuti, Cláudio Mendes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5480103/
https://www.ncbi.nlm.nih.gov/pubmed/28637451
http://dx.doi.org/10.1186/s12903-017-0390-5
_version_ 1783245235808108544
author Almeida, Vanessa Camillo
Pinheiro, Lucas Rodrigues
Salineiro, Fernanda Cristina Sales
Mendes, Fausto Medeiros
Neto, João Batista César
Cavalcanti, Marcelo Gusmão Paraíso
Pannuti, Cláudio Mendes
author_facet Almeida, Vanessa Camillo
Pinheiro, Lucas Rodrigues
Salineiro, Fernanda Cristina Sales
Mendes, Fausto Medeiros
Neto, João Batista César
Cavalcanti, Marcelo Gusmão Paraíso
Pannuti, Cláudio Mendes
author_sort Almeida, Vanessa Camillo
collection PubMed
description BACKGROUND: Cone beam computed tomography (CBCT) has been largely used in dentistry. Nevertheless, there is lack of evidence regarding CBCT accuracy in the diagnosis of early periodontal lesions as well as the correlation between accuracy and lesion size. The aim of this study was to evaluate accuracy of CBCT and conventional intraoral radiographs in detecting different-sized interproximal bone lesions created in pig mandibles. The hypothesis was that CBCT accuracy would be superior to radiographs in detecting incipient bone lesions. METHODS: Twenty swine dry mandibles were used, totalizing 80 experimental sites. Four groups were created according to exposure time to perchloric acid 70–72%: controls (no exposure), 2-hour exposure, 4-hour exposure, and 6-hour exposure. Standardized CBCT and conventional intraoral radiographs were taken and analyzed by two trained radiologists. The presence of lesions in the dry mandible was considered the gold standard. Sensitivity, specificity, and accuracy in detecting different-sized bone lesions were calculated for CBCT and intraoral radiographs. RESULTS: Accuracy of CBCT ranged from 0.762 to 0.825 and accuracy of periapical radiography ranged from 0.700 to 0.813, according to examiner and time of acid exposure. Inter-examiner agreement varied from slight to fair, whereas intra-examiner agreement varied from moderate to substantial. CONCLUSIONS: CBCT performance was not superior to that provided by conventional intraoral radiographs in the detection of interproximal bone loss.
format Online
Article
Text
id pubmed-5480103
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54801032017-06-23 Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles Almeida, Vanessa Camillo Pinheiro, Lucas Rodrigues Salineiro, Fernanda Cristina Sales Mendes, Fausto Medeiros Neto, João Batista César Cavalcanti, Marcelo Gusmão Paraíso Pannuti, Cláudio Mendes BMC Oral Health Research Article BACKGROUND: Cone beam computed tomography (CBCT) has been largely used in dentistry. Nevertheless, there is lack of evidence regarding CBCT accuracy in the diagnosis of early periodontal lesions as well as the correlation between accuracy and lesion size. The aim of this study was to evaluate accuracy of CBCT and conventional intraoral radiographs in detecting different-sized interproximal bone lesions created in pig mandibles. The hypothesis was that CBCT accuracy would be superior to radiographs in detecting incipient bone lesions. METHODS: Twenty swine dry mandibles were used, totalizing 80 experimental sites. Four groups were created according to exposure time to perchloric acid 70–72%: controls (no exposure), 2-hour exposure, 4-hour exposure, and 6-hour exposure. Standardized CBCT and conventional intraoral radiographs were taken and analyzed by two trained radiologists. The presence of lesions in the dry mandible was considered the gold standard. Sensitivity, specificity, and accuracy in detecting different-sized bone lesions were calculated for CBCT and intraoral radiographs. RESULTS: Accuracy of CBCT ranged from 0.762 to 0.825 and accuracy of periapical radiography ranged from 0.700 to 0.813, according to examiner and time of acid exposure. Inter-examiner agreement varied from slight to fair, whereas intra-examiner agreement varied from moderate to substantial. CONCLUSIONS: CBCT performance was not superior to that provided by conventional intraoral radiographs in the detection of interproximal bone loss. BioMed Central 2017-06-21 /pmc/articles/PMC5480103/ /pubmed/28637451 http://dx.doi.org/10.1186/s12903-017-0390-5 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Almeida, Vanessa Camillo
Pinheiro, Lucas Rodrigues
Salineiro, Fernanda Cristina Sales
Mendes, Fausto Medeiros
Neto, João Batista César
Cavalcanti, Marcelo Gusmão Paraíso
Pannuti, Cláudio Mendes
Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
title Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
title_full Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
title_fullStr Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
title_full_unstemmed Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
title_short Performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
title_sort performance of cone beam computed tomography and conventional intraoral radiographs in detecting interproximal alveolar bone lesions: a study in pig mandibles
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5480103/
https://www.ncbi.nlm.nih.gov/pubmed/28637451
http://dx.doi.org/10.1186/s12903-017-0390-5
work_keys_str_mv AT almeidavanessacamillo performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles
AT pinheirolucasrodrigues performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles
AT salineirofernandacristinasales performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles
AT mendesfaustomedeiros performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles
AT netojoaobatistacesar performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles
AT cavalcantimarcelogusmaoparaiso performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles
AT pannuticlaudiomendes performanceofconebeamcomputedtomographyandconventionalintraoralradiographsindetectinginterproximalalveolarbonelesionsastudyinpigmandibles