Cargando…
Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography
PURPOSE: The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental µ-SLA system. MATERIALS AND METHODS: Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. N...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Prosthodontics
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5483403/ https://www.ncbi.nlm.nih.gov/pubmed/28680548 http://dx.doi.org/10.4047/jap.2017.9.3.176 |
_version_ | 1783245749963718656 |
---|---|
author | Kim, Dong-Yeon Kim, Chong-Myeong Kim, Ji-Hwan Kim, Hae-Young Kim, Woong-Chul |
author_facet | Kim, Dong-Yeon Kim, Chong-Myeong Kim, Ji-Hwan Kim, Hae-Young Kim, Woong-Chul |
author_sort | Kim, Dong-Yeon |
collection | PubMed |
description | PURPOSE: The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental µ-SLA system. MATERIALS AND METHODS: Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope (160 ×) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (α=.05). RESULTS: The mean (±standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: 81.5±73.8, 98.1±76.1, 87.1±44.8, and 146.8±78.7 µm in the LW group; 76.8±48.0, 141.7±57.1, 80.7±47.5, and 194.69±63.8 µm in the NC group; and 124.2±52.0, 199.5±71.0, 67.1±37.6, and 244.5±58.9 µm in the CC group. CONCLUSION: The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice. |
format | Online Article Text |
id | pubmed-5483403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Academy of Prosthodontics |
record_format | MEDLINE/PubMed |
spelling | pubmed-54834032017-07-05 Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography Kim, Dong-Yeon Kim, Chong-Myeong Kim, Ji-Hwan Kim, Hae-Young Kim, Woong-Chul J Adv Prosthodont Original Article PURPOSE: The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental µ-SLA system. MATERIALS AND METHODS: Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope (160 ×) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (α=.05). RESULTS: The mean (±standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: 81.5±73.8, 98.1±76.1, 87.1±44.8, and 146.8±78.7 µm in the LW group; 76.8±48.0, 141.7±57.1, 80.7±47.5, and 194.69±63.8 µm in the NC group; and 124.2±52.0, 199.5±71.0, 67.1±37.6, and 244.5±58.9 µm in the CC group. CONCLUSION: The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice. The Korean Academy of Prosthodontics 2017-06 2017-06-19 /pmc/articles/PMC5483403/ /pubmed/28680548 http://dx.doi.org/10.4047/jap.2017.9.3.176 Text en © 2017 The Korean Academy of Prosthodontics http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Dong-Yeon Kim, Chong-Myeong Kim, Ji-Hwan Kim, Hae-Young Kim, Woong-Chul Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography |
title | Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography |
title_full | Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography |
title_fullStr | Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography |
title_full_unstemmed | Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography |
title_short | Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography |
title_sort | evaluation of marginal and internal gaps of ni-cr and co-cr alloy copings manufactured by microstereolithography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5483403/ https://www.ncbi.nlm.nih.gov/pubmed/28680548 http://dx.doi.org/10.4047/jap.2017.9.3.176 |
work_keys_str_mv | AT kimdongyeon evaluationofmarginalandinternalgapsofnicrandcocralloycopingsmanufacturedbymicrostereolithography AT kimchongmyeong evaluationofmarginalandinternalgapsofnicrandcocralloycopingsmanufacturedbymicrostereolithography AT kimjihwan evaluationofmarginalandinternalgapsofnicrandcocralloycopingsmanufacturedbymicrostereolithography AT kimhaeyoung evaluationofmarginalandinternalgapsofnicrandcocralloycopingsmanufacturedbymicrostereolithography AT kimwoongchul evaluationofmarginalandinternalgapsofnicrandcocralloycopingsmanufacturedbymicrostereolithography |