Cargando…

Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials

BACKGROUND: For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia mach...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Yoon Ji, Min, Sam Hong, Park, Jeong Jun, Cho, Jang Eun, Yoon, Seung Zhoo, Yoon, Suk Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484232/
https://www.ncbi.nlm.nih.gov/pubmed/28640124
http://dx.doi.org/10.1097/MD.0000000000007239
_version_ 1783245843052101632
author Choi, Yoon Ji
Min, Sam Hong
Park, Jeong Jun
Cho, Jang Eun
Yoon, Seung Zhoo
Yoon, Suk Min
author_facet Choi, Yoon Ji
Min, Sam Hong
Park, Jeong Jun
Cho, Jang Eun
Yoon, Seung Zhoo
Yoon, Suk Min
author_sort Choi, Yoon Ji
collection PubMed
description BACKGROUND: For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia machines. METHODS: The patients were divided into 11 groups according to the anesthesia machine used (Ohmeda, Excel; Avance; Dräger, Cato; and Primus) and the fresh gas flow (FGF) rate (0.5, 1, and 4 L/min). The temperature and absolute humidity of the inspired gas in the inspiratory limbs were measured at 5, 10, 15, 30, 45, 60, 75, 90, 105, and 120 minutes in 9 patients scheduled for total thyroidectomy or cervical spine operation in each group. RESULTS: The anesthesia machines of Excel, Avance, Cato, and Primus did not show statistically significant changes in the inspired gas temperatures over time within each group with various FGFs. They, however, showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with low FGF anesthesia (P < .05). The anesthesia machines of Cato and Primus showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with an FGF of 4 L/min (P < .05). However, even with low-flow anesthesia, the temperatures and absolute humidities of the inspired gas for all anesthesia machines were lower than the recommended values. CONCLUSION: There were statistical differences in the provision of humidity among different anesthesia workstations. The Cato and Primus workstations were superior to Excel and Avance. However, even these were unsatisfactory in humans. Therefore, additional devices that provide inspired gases with adequate heat and humidity are needed for those undergoing general anesthetic procedures.
format Online
Article
Text
id pubmed-5484232
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-54842322017-07-06 Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials Choi, Yoon Ji Min, Sam Hong Park, Jeong Jun Cho, Jang Eun Yoon, Seung Zhoo Yoon, Suk Min Medicine (Baltimore) 3300 BACKGROUND: For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia machines. METHODS: The patients were divided into 11 groups according to the anesthesia machine used (Ohmeda, Excel; Avance; Dräger, Cato; and Primus) and the fresh gas flow (FGF) rate (0.5, 1, and 4 L/min). The temperature and absolute humidity of the inspired gas in the inspiratory limbs were measured at 5, 10, 15, 30, 45, 60, 75, 90, 105, and 120 minutes in 9 patients scheduled for total thyroidectomy or cervical spine operation in each group. RESULTS: The anesthesia machines of Excel, Avance, Cato, and Primus did not show statistically significant changes in the inspired gas temperatures over time within each group with various FGFs. They, however, showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with low FGF anesthesia (P < .05). The anesthesia machines of Cato and Primus showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with an FGF of 4 L/min (P < .05). However, even with low-flow anesthesia, the temperatures and absolute humidities of the inspired gas for all anesthesia machines were lower than the recommended values. CONCLUSION: There were statistical differences in the provision of humidity among different anesthesia workstations. The Cato and Primus workstations were superior to Excel and Avance. However, even these were unsatisfactory in humans. Therefore, additional devices that provide inspired gases with adequate heat and humidity are needed for those undergoing general anesthetic procedures. Wolters Kluwer Health 2017-06-23 /pmc/articles/PMC5484232/ /pubmed/28640124 http://dx.doi.org/10.1097/MD.0000000000007239 Text en Copyright © 2017 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0
spellingShingle 3300
Choi, Yoon Ji
Min, Sam Hong
Park, Jeong Jun
Cho, Jang Eun
Yoon, Seung Zhoo
Yoon, Suk Min
Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials
title Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials
title_full Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials
title_fullStr Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials
title_full_unstemmed Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials
title_short Comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: Updated guidelines for reporting parallel group randomized trials
title_sort comparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations: updated guidelines for reporting parallel group randomized trials
topic 3300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484232/
https://www.ncbi.nlm.nih.gov/pubmed/28640124
http://dx.doi.org/10.1097/MD.0000000000007239
work_keys_str_mv AT choiyoonji comparisonofthetemperatureandhumidityintheanestheticbreathingcircuitamongdifferentanestheticworkstationsupdatedguidelinesforreportingparallelgrouprandomizedtrials
AT minsamhong comparisonofthetemperatureandhumidityintheanestheticbreathingcircuitamongdifferentanestheticworkstationsupdatedguidelinesforreportingparallelgrouprandomizedtrials
AT parkjeongjun comparisonofthetemperatureandhumidityintheanestheticbreathingcircuitamongdifferentanestheticworkstationsupdatedguidelinesforreportingparallelgrouprandomizedtrials
AT chojangeun comparisonofthetemperatureandhumidityintheanestheticbreathingcircuitamongdifferentanestheticworkstationsupdatedguidelinesforreportingparallelgrouprandomizedtrials
AT yoonseungzhoo comparisonofthetemperatureandhumidityintheanestheticbreathingcircuitamongdifferentanestheticworkstationsupdatedguidelinesforreportingparallelgrouprandomizedtrials
AT yoonsukmin comparisonofthetemperatureandhumidityintheanestheticbreathingcircuitamongdifferentanestheticworkstationsupdatedguidelinesforreportingparallelgrouprandomizedtrials