Cargando…
Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI
PURPOSE: Fitting tracer kinetic models using linear methods is much faster than using their nonlinear counterparts, although this comes often at the expense of reduced accuracy and precision. The aim of this study was to derive and compare the performance of the linear compartmental tissue uptake (C...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484345/ https://www.ncbi.nlm.nih.gov/pubmed/27605429 http://dx.doi.org/10.1002/mrm.26324 |
_version_ | 1783245868556615680 |
---|---|
author | Kallehauge, Jesper F. Sourbron, Steven Irving, Benjamin Tanderup, Kari Schnabel, Julia A. Chappell, Michael A. |
author_facet | Kallehauge, Jesper F. Sourbron, Steven Irving, Benjamin Tanderup, Kari Schnabel, Julia A. Chappell, Michael A. |
author_sort | Kallehauge, Jesper F. |
collection | PubMed |
description | PURPOSE: Fitting tracer kinetic models using linear methods is much faster than using their nonlinear counterparts, although this comes often at the expense of reduced accuracy and precision. The aim of this study was to derive and compare the performance of the linear compartmental tissue uptake (CTU) model with its nonlinear version with respect to their percentage error and precision. THEORY AND METHODS: The linear and nonlinear CTU models were initially compared using simulations with varying noise and temporal sampling. Subsequently, the clinical applicability of the linear model was demonstrated on 14 patients with locally advanced cervical cancer examined with dynamic contrast‐enhanced magnetic resonance imaging. RESULTS: Simulations revealed equal percentage error and precision when noise was within clinical achievable ranges (contrast‐to‐noise ratio >10). The linear method was significantly faster than the nonlinear method, with a minimum speedup of around 230 across all tested sampling rates. Clinical analysis revealed that parameters estimated using the linear and nonlinear CTU model were highly correlated (ρ ≥ 0.95). CONCLUSION: The linear CTU model is computationally more efficient and more stable against temporal downsampling, whereas the nonlinear method is more robust to variations in noise. The two methods may be used interchangeably within clinical achievable ranges of temporal sampling and noise. Magn Reson Med 77:2414–2423, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
format | Online Article Text |
id | pubmed-5484345 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-54843452017-07-10 Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI Kallehauge, Jesper F. Sourbron, Steven Irving, Benjamin Tanderup, Kari Schnabel, Julia A. Chappell, Michael A. Magn Reson Med Computer Processing and Modeling—Full Papers PURPOSE: Fitting tracer kinetic models using linear methods is much faster than using their nonlinear counterparts, although this comes often at the expense of reduced accuracy and precision. The aim of this study was to derive and compare the performance of the linear compartmental tissue uptake (CTU) model with its nonlinear version with respect to their percentage error and precision. THEORY AND METHODS: The linear and nonlinear CTU models were initially compared using simulations with varying noise and temporal sampling. Subsequently, the clinical applicability of the linear model was demonstrated on 14 patients with locally advanced cervical cancer examined with dynamic contrast‐enhanced magnetic resonance imaging. RESULTS: Simulations revealed equal percentage error and precision when noise was within clinical achievable ranges (contrast‐to‐noise ratio >10). The linear method was significantly faster than the nonlinear method, with a minimum speedup of around 230 across all tested sampling rates. Clinical analysis revealed that parameters estimated using the linear and nonlinear CTU model were highly correlated (ρ ≥ 0.95). CONCLUSION: The linear CTU model is computationally more efficient and more stable against temporal downsampling, whereas the nonlinear method is more robust to variations in noise. The two methods may be used interchangeably within clinical achievable ranges of temporal sampling and noise. Magn Reson Med 77:2414–2423, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2016-09-08 2017-06 /pmc/articles/PMC5484345/ /pubmed/27605429 http://dx.doi.org/10.1002/mrm.26324 Text en © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Computer Processing and Modeling—Full Papers Kallehauge, Jesper F. Sourbron, Steven Irving, Benjamin Tanderup, Kari Schnabel, Julia A. Chappell, Michael A. Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI |
title | Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI |
title_full | Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI |
title_fullStr | Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI |
title_full_unstemmed | Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI |
title_short | Comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced MRI |
title_sort | comparison of linear and nonlinear implementation of the compartmental tissue uptake model for dynamic contrast‐enhanced mri |
topic | Computer Processing and Modeling—Full Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484345/ https://www.ncbi.nlm.nih.gov/pubmed/27605429 http://dx.doi.org/10.1002/mrm.26324 |
work_keys_str_mv | AT kallehaugejesperf comparisonoflinearandnonlinearimplementationofthecompartmentaltissueuptakemodelfordynamiccontrastenhancedmri AT sourbronsteven comparisonoflinearandnonlinearimplementationofthecompartmentaltissueuptakemodelfordynamiccontrastenhancedmri AT irvingbenjamin comparisonoflinearandnonlinearimplementationofthecompartmentaltissueuptakemodelfordynamiccontrastenhancedmri AT tanderupkari comparisonoflinearandnonlinearimplementationofthecompartmentaltissueuptakemodelfordynamiccontrastenhancedmri AT schnabeljuliaa comparisonoflinearandnonlinearimplementationofthecompartmentaltissueuptakemodelfordynamiccontrastenhancedmri AT chappellmichaela comparisonoflinearandnonlinearimplementationofthecompartmentaltissueuptakemodelfordynamiccontrastenhancedmri |