Cargando…

Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison

BACKGROUND: Central venous catheter-related infections (CVCIs) in patients on maintenance hemodialysis (HD) have been documented due to unsafe/unsterile manipulations by nurses during HD machine deconnection and reconnection. Given the gravity of CVCIs in HD patients using catheter access, precise,...

Descripción completa

Detalles Bibliográficos
Autores principales: Tacchini-Jacquier, Nadine, Verloo, Henk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484563/
https://www.ncbi.nlm.nih.gov/pubmed/28684919
http://dx.doi.org/10.2147/IJNRD.S130738
_version_ 1783245904608755712
author Tacchini-Jacquier, Nadine
Verloo, Henk
author_facet Tacchini-Jacquier, Nadine
Verloo, Henk
author_sort Tacchini-Jacquier, Nadine
collection PubMed
description BACKGROUND: Central venous catheter-related infections (CVCIs) in patients on maintenance hemodialysis (HD) have been documented due to unsafe/unsterile manipulations by nurses during HD machine deconnection and reconnection. Given the gravity of CVCIs in HD patients using catheter access, precise, safe installation of the device, and good nursing technique are crucial. AIM: To assess and compare safety performance and complications of a Y-connection (n=133) versus the usual tunneled central venous catheter (CVC) technique (n=73) among HD patients and then explore preferences between techniques among patients and frontline HD nurses. MATERIALS AND METHODS: A prospective, comparative, 3-month point prevalence survey was conducted among HD outpatients and frontline HD nurses in a 600-bed teaching hospital in the canton of Valais. RESULTS: Nine HD outpatients (average age, 68.3 years; SD=12.3) were recruited. The two techniques showed no differences in C-reactive protein levels (p=0.465), pain (p=1.00), or local complications due to dressings soiled by exudate at the catheter insert point (p=0.066). The relative risk ratio (RR) indicated that CVCI was 1.667 times (95% CI; 0.437, 6.358, p=0.50) more likely with a Y-connection. Neither the Y-connection technique (RR 1.63; [95% CI; 0.554, 4.790]; p=0.32) nor usual CVC technique (RR 0.58; [95% CI; 0.277, 1.217]; p=0.13) were significant relative risk factors for complications. Fifty-seven percent of HD patients stated that they felt more secure and comfortable using the Y-connection technique than the usual care technique. Eleven of the 12 nurses involved preferred the Y-connection technique, feeling that is was safer and easier in use. CONCLUSION: No difference was found in the complication rates of two blood restitution techniques – the Y-connection versus the usual CVC technique. HD outpatients and nurses preferred the Y-connection for blood restitution.
format Online
Article
Text
id pubmed-5484563
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-54845632017-07-06 Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison Tacchini-Jacquier, Nadine Verloo, Henk Int J Nephrol Renovasc Dis Original Research BACKGROUND: Central venous catheter-related infections (CVCIs) in patients on maintenance hemodialysis (HD) have been documented due to unsafe/unsterile manipulations by nurses during HD machine deconnection and reconnection. Given the gravity of CVCIs in HD patients using catheter access, precise, safe installation of the device, and good nursing technique are crucial. AIM: To assess and compare safety performance and complications of a Y-connection (n=133) versus the usual tunneled central venous catheter (CVC) technique (n=73) among HD patients and then explore preferences between techniques among patients and frontline HD nurses. MATERIALS AND METHODS: A prospective, comparative, 3-month point prevalence survey was conducted among HD outpatients and frontline HD nurses in a 600-bed teaching hospital in the canton of Valais. RESULTS: Nine HD outpatients (average age, 68.3 years; SD=12.3) were recruited. The two techniques showed no differences in C-reactive protein levels (p=0.465), pain (p=1.00), or local complications due to dressings soiled by exudate at the catheter insert point (p=0.066). The relative risk ratio (RR) indicated that CVCI was 1.667 times (95% CI; 0.437, 6.358, p=0.50) more likely with a Y-connection. Neither the Y-connection technique (RR 1.63; [95% CI; 0.554, 4.790]; p=0.32) nor usual CVC technique (RR 0.58; [95% CI; 0.277, 1.217]; p=0.13) were significant relative risk factors for complications. Fifty-seven percent of HD patients stated that they felt more secure and comfortable using the Y-connection technique than the usual care technique. Eleven of the 12 nurses involved preferred the Y-connection technique, feeling that is was safer and easier in use. CONCLUSION: No difference was found in the complication rates of two blood restitution techniques – the Y-connection versus the usual CVC technique. HD outpatients and nurses preferred the Y-connection for blood restitution. Dove Medical Press 2017-06-21 /pmc/articles/PMC5484563/ /pubmed/28684919 http://dx.doi.org/10.2147/IJNRD.S130738 Text en © 2017 Tacchini-Jacquier and Verloo. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Tacchini-Jacquier, Nadine
Verloo, Henk
Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
title Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
title_full Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
title_fullStr Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
title_full_unstemmed Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
title_short Point prevalence of complications between the Y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
title_sort point prevalence of complications between the y connection technique and the usual care technique for blood restitution in patients of an outpatient hemodialysis unit: a comparison
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484563/
https://www.ncbi.nlm.nih.gov/pubmed/28684919
http://dx.doi.org/10.2147/IJNRD.S130738
work_keys_str_mv AT tacchinijacquiernadine pointprevalenceofcomplicationsbetweentheyconnectiontechniqueandtheusualcaretechniqueforbloodrestitutioninpatientsofanoutpatienthemodialysisunitacomparison
AT verloohenk pointprevalenceofcomplicationsbetweentheyconnectiontechniqueandtheusualcaretechniqueforbloodrestitutioninpatientsofanoutpatienthemodialysisunitacomparison