Cargando…

The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability

BACKGROUND: The purpose of this study was to investigate the stability of dual-taper modular implants following impaction forces delivered at varying locations as measured by the distraction forces required to disassemble the components. METHODS: Distraction of the head-neck and neck-stem (NS) taper...

Descripción completa

Detalles Bibliográficos
Autores principales: Frisch, Nicholas B., Lynch, Jonathan R., Banglmaier, Richard F., Silverton, Craig D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484971/
https://www.ncbi.nlm.nih.gov/pubmed/28695184
http://dx.doi.org/10.1016/j.artd.2016.08.005
_version_ 1783245976461377536
author Frisch, Nicholas B.
Lynch, Jonathan R.
Banglmaier, Richard F.
Silverton, Craig D.
author_facet Frisch, Nicholas B.
Lynch, Jonathan R.
Banglmaier, Richard F.
Silverton, Craig D.
author_sort Frisch, Nicholas B.
collection PubMed
description BACKGROUND: The purpose of this study was to investigate the stability of dual-taper modular implants following impaction forces delivered at varying locations as measured by the distraction forces required to disassemble the components. METHODS: Distraction of the head-neck and neck-stem (NS) tapers of dual-taper modular implants with 0°, 8°, and 15° neck angles were measured utilizing a custom-made distraction fixture attached to a servohydraulic materials test machine. Distraction was measured after hand pressing the components as well as following a simulated firm hammer blow impaction. Impacts to the 0°, 8°, 15° necks were directed axially in line with the neck, 10° anterior, and 10° proximal to the axis of the neck, respectively. RESULTS: Impaction increased the range of NS component distraction forces when compared to hand pressed components (1125-1743 N vs 248-302 N, respectively). Off-axis impacts resulted in significantly reduced mean (±95% confidence interval) distraction forces (8° neck, 1125 ± 117 N; 15° neck, 1212 ± 73 N), which were up to 35% lower than the mean distraction force for axial impacts to the 0° neck (1743 ± 138 N). CONCLUSIONS: Direction of impaction influences stability of the modular interface. The greatest stability was achieved with impaction directed in line with the longitudinal axis of the taper junction. Off-axis impaction of the 8° and 15° neck led to significantly reduced stability at the NS. Improving stability of dual-taper modular hip prostheses with appropriately directed impaction may help to minimize micromotion, component settling, fretting corrosion, and subsequent failure.
format Online
Article
Text
id pubmed-5484971
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-54849712017-07-10 The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability Frisch, Nicholas B. Lynch, Jonathan R. Banglmaier, Richard F. Silverton, Craig D. Arthroplast Today Original Research BACKGROUND: The purpose of this study was to investigate the stability of dual-taper modular implants following impaction forces delivered at varying locations as measured by the distraction forces required to disassemble the components. METHODS: Distraction of the head-neck and neck-stem (NS) tapers of dual-taper modular implants with 0°, 8°, and 15° neck angles were measured utilizing a custom-made distraction fixture attached to a servohydraulic materials test machine. Distraction was measured after hand pressing the components as well as following a simulated firm hammer blow impaction. Impacts to the 0°, 8°, 15° necks were directed axially in line with the neck, 10° anterior, and 10° proximal to the axis of the neck, respectively. RESULTS: Impaction increased the range of NS component distraction forces when compared to hand pressed components (1125-1743 N vs 248-302 N, respectively). Off-axis impacts resulted in significantly reduced mean (±95% confidence interval) distraction forces (8° neck, 1125 ± 117 N; 15° neck, 1212 ± 73 N), which were up to 35% lower than the mean distraction force for axial impacts to the 0° neck (1743 ± 138 N). CONCLUSIONS: Direction of impaction influences stability of the modular interface. The greatest stability was achieved with impaction directed in line with the longitudinal axis of the taper junction. Off-axis impaction of the 8° and 15° neck led to significantly reduced stability at the NS. Improving stability of dual-taper modular hip prostheses with appropriately directed impaction may help to minimize micromotion, component settling, fretting corrosion, and subsequent failure. Elsevier 2016-10-07 /pmc/articles/PMC5484971/ /pubmed/28695184 http://dx.doi.org/10.1016/j.artd.2016.08.005 Text en © 2016 Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Frisch, Nicholas B.
Lynch, Jonathan R.
Banglmaier, Richard F.
Silverton, Craig D.
The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
title The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
title_full The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
title_fullStr The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
title_full_unstemmed The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
title_short The stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
title_sort stability of dual-taper modular hip implants: a biomechanical analysis examining the effect of impact location on component stability
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484971/
https://www.ncbi.nlm.nih.gov/pubmed/28695184
http://dx.doi.org/10.1016/j.artd.2016.08.005
work_keys_str_mv AT frischnicholasb thestabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT lynchjonathanr thestabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT banglmaierrichardf thestabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT silvertoncraigd thestabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT frischnicholasb stabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT lynchjonathanr stabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT banglmaierrichardf stabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability
AT silvertoncraigd stabilityofdualtapermodularhipimplantsabiomechanicalanalysisexaminingtheeffectofimpactlocationoncomponentstability