Cargando…

C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy

The C 1s signal from ubiquitous carbon contamination on samples forming during air exposure, so called adventitious carbon (AdC) layers, is the most common binding energy (BE) reference in X‐ray photoelectron spectroscopy studies. We demonstrate here, by using a series of transition‐metal nitride fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Greczynski, Grzegorz, Hultman, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484993/
https://www.ncbi.nlm.nih.gov/pubmed/28295951
http://dx.doi.org/10.1002/cphc.201700126
_version_ 1783245981738860544
author Greczynski, Grzegorz
Hultman, Lars
author_facet Greczynski, Grzegorz
Hultman, Lars
author_sort Greczynski, Grzegorz
collection PubMed
description The C 1s signal from ubiquitous carbon contamination on samples forming during air exposure, so called adventitious carbon (AdC) layers, is the most common binding energy (BE) reference in X‐ray photoelectron spectroscopy studies. We demonstrate here, by using a series of transition‐metal nitride films with different AdC coverage, that the BE of the C 1s peak [Formula: see text] varies by as much as 1.44 eV. This is a factor of 10 more than the typical resolvable difference between two chemical states of the same element, which makes BE referencing against the C 1s peak highly unreliable. Surprisingly, we find that C 1s shifts correlate to changes in sample work function [Formula: see text] , such that the sum [Formula: see text] is constant at 289.50±0.15 eV, irrespective of materials system and air exposure time, indicating vacuum level alignment. This discovery allows for significantly better accuracy of chemical state determination than offered by the conventional methods. Our findings are not specific to nitrides and likely apply to all systems in which charge transfer at the AdC/substrate interface is negligible.
format Online
Article
Text
id pubmed-5484993
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-54849932017-07-24 C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy Greczynski, Grzegorz Hultman, Lars Chemphyschem Communications The C 1s signal from ubiquitous carbon contamination on samples forming during air exposure, so called adventitious carbon (AdC) layers, is the most common binding energy (BE) reference in X‐ray photoelectron spectroscopy studies. We demonstrate here, by using a series of transition‐metal nitride films with different AdC coverage, that the BE of the C 1s peak [Formula: see text] varies by as much as 1.44 eV. This is a factor of 10 more than the typical resolvable difference between two chemical states of the same element, which makes BE referencing against the C 1s peak highly unreliable. Surprisingly, we find that C 1s shifts correlate to changes in sample work function [Formula: see text] , such that the sum [Formula: see text] is constant at 289.50±0.15 eV, irrespective of materials system and air exposure time, indicating vacuum level alignment. This discovery allows for significantly better accuracy of chemical state determination than offered by the conventional methods. Our findings are not specific to nitrides and likely apply to all systems in which charge transfer at the AdC/substrate interface is negligible. John Wiley and Sons Inc. 2017-04-11 2017-06-20 /pmc/articles/PMC5484993/ /pubmed/28295951 http://dx.doi.org/10.1002/cphc.201700126 Text en © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Communications
Greczynski, Grzegorz
Hultman, Lars
C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy
title C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy
title_full C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy
title_fullStr C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy
title_full_unstemmed C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy
title_short C 1s Peak of Adventitious Carbon Aligns to the Vacuum Level: Dire Consequences for Material's Bonding Assignment by Photoelectron Spectroscopy
title_sort c 1s peak of adventitious carbon aligns to the vacuum level: dire consequences for material's bonding assignment by photoelectron spectroscopy
topic Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5484993/
https://www.ncbi.nlm.nih.gov/pubmed/28295951
http://dx.doi.org/10.1002/cphc.201700126
work_keys_str_mv AT greczynskigrzegorz c1speakofadventitiouscarbonalignstothevacuumleveldireconsequencesformaterialsbondingassignmentbyphotoelectronspectroscopy
AT hultmanlars c1speakofadventitiouscarbonalignstothevacuumleveldireconsequencesformaterialsbondingassignmentbyphotoelectronspectroscopy