Cargando…

Solidification and Biotoxicity Assessment of Thermally Treated Municipal Solid Waste Incineration (MSWI) Fly Ash

In the present work, thermal treatment was used to stabilize municipal solid waste incineration (MSWI) fly ash, which was considered hazardous waste. Toxicity characteristic leaching procedure (TCLP) results indicated that, after the thermal process, the leaching concentrations of Pb, Cu, and Zn dec...

Descripción completa

Detalles Bibliográficos
Autores principales: Gong, Bing, Deng, Yi, Yang, Yuanyi, Tan, Swee Ngin, Liu, Qianni, Yang, Weizhong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5486312/
https://www.ncbi.nlm.nih.gov/pubmed/28604580
http://dx.doi.org/10.3390/ijerph14060626